• Title/Summary/Keyword: Skill accuracy

Search Result 145, Processing Time 0.019 seconds

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Development of cardiopulmonary resuscitation nursing education program of web-based instruction (웹 기반의 심폐소생술 간호교육 프로그램 개발)

  • Sin, Hae-Won;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.25-39
    • /
    • 2002
  • The purpose of this study is to develop and evaluate a web-based instruction Program(WBI) to help nurses improving their knowledge and skill of cardiopulmonary resuscitation. Using the model of web-based instruction(WBI) program designed by Rhu(1999), this study was carried out during February-April 2002 in five different steps; analysis, design, data collection and reconstruction, programming and publishing, and evaluation. The results of the study were as follows; 1) The goal of this program was focused on improving accuracy of knowledge and skills of cardiopulmonary resuscitation. The program texts consists of the concepts and importances of cardiopulmonary resuscitation(CPR), basic life support(BLS), advanced cardiac life support(ACLS), treatment of CPR, nursing care after CPR treatment. And in the file making step, photographs, drawings and image files were collected and edited by web-editor(Namo), scanner and Adobe photoshop program. Then, the files were modified and posted on the web by file transfer protocol(FTP). Finally, the program was demonstrated and once again revised by the result, and then completed. 2) For the evaluation of the program, 36 nurses who in K university hospital located in D city, and related questionnaire were distributed to them as well. Higher scores were given by the nurses in its learning contents with $4.2{\pm}.67$, and in its structuring and interaction of the program with $4.0{\pm}.79$, and also in its satisfactory of the program with $4.2{\pm}.58$ respectively. In conclusion, if the contents of this WBI educational program upgrade further based upon analysis and applying of the results the program evaluation, it is considered as an effective tool to implement for continuing education as life-long educational system for nurse.

  • PDF

A Study on Qulity Perceptions and Satisfaction for Medical Service Marketing (의료서비스 마케팅을 위한 품질지각과 만족에 관한 연구)

  • Yoo, Dong-Keun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.97-114
    • /
    • 1996
  • INSTRODUCTION Service quality is, unlike goods quality, an abstract and elusive constuct. Service quality and its requirements are not easily understood by consumers, and also present some critical research problems. However, quality is very important to marketers and consumers in that it has many strategic benefits in contributing to profitability of marketing activities and consumers' problem-solving activities. Moreover, despite the phenomenal growth of medical service sector, few researchers have attempted to define and model medical service quality. Especially, little research has focused on the evaluation of medical service quality and patient satisfaction from the perspectives of both the provider and the patient. As competition intensifies and patients are demanding higher quality of medical service, medical service quality and patient satisfaction has emerged as a critical research topic. The major purpose of this article is to explore the concept of medical service quality and its evaluation from both nurse and patient perspectives. This article attempts to achieve its purpose by (1)classfying critical service attibutes into threecategories(satisfiers, hygiene factors, and performance factors). (2)measuring the relative importance of need criteria, (3)evaluating SERVPERF model and SERVQUAL model in medical service sector, and (4)identifying the relationship between perceived quality and overall patient satisfaction. METHOD Data were gathered from a sample of 217 patients and 179 nurses in Seoul-area general hospitals. From the review of previous literature, 50 survey items representing various facets of the medical service quality were developed to form a questionnaire. A five-point scale ranging from "Strongly Agree"(5) to "Strongly Disagree"(1) accompanied each statement(expectation statements, perception statements, and importance statements). To measure overall satisfaction, a seven-point scale was used, ranging from "Very Satisfied"(7) to "Very Dissatisfied"(1) with no verbal labels for scale points 2 through 6 RESULTS In explaining the relationship between perceived performance and overall satisfaction, only 31 variables out of original 50 survey items were proven to be statistically significant. Hence, a penalty-reward analysis was performed on theses 31 critical attributes to find out 17 satisfiers, 8 hygiene factors, and 4 performance factors in patient perspective. The role(category) of each service quality attribute in relation to patient satisfaction was com pared across two groups, that is, patients and nurses. They were little overlapped, suggesting that two groups had different sets of 'perceived quality' attributes. Principal components factor analyses of the patients' and nurses' responses were performed to identify the underlying dimensions for the set of performance(experience) statements. 28 variables were analyzed by using a varimax rotation after deleting three obscure variables. The number of factors to be extracted was determined by evaluating the eigenvalue scores. Six factors wereextracted, accounting for 57.1% of the total variance. Reliability analysis was performed to refine the factors further. Using coefficient alpha, scores of .84 to .65 were obtained. Individual-item analysis indicated that all statements in each of the factors should remain. On 26 attributes of 31 critical service quality attributes, there were gaps between actual patient's importance of need criteria and nurse perceptions of them. Those critical attributes could be classified into four categories based on the relative importance of need criteria and perceived performance from the perspective of patient. This analysis is useful in developing strategic plans for performance improvement. (1) top priorities(high importance and low performance) (in this study)- more health-related information -accuracy in billing - quality of food - appointments at my convenience - information about tests and treatments - prompt service of business office -adequacy of accommodations(elevators, etc) (2) current strengths(high importance and high performance) (3)unnecessary strengths(low importance and high performance) (4) low priorities(low importance and low performance) While 26 service quality attributes of SERPERF model were significantly related to patient satisfation, only 13 attributes of SERVQUAL model were significantly related. This result suggested that only experience-based norms(SERVPERF model) were more appropriate than expectations to serve as a benchmark against which service experiences were compared(SERVQUAL model). However, it must be noted that the degree of association to overall satisfaction was not consistent. There were some gaps between nurse percetions and patient perception of medical service performance. From the patient's viewpoint, "personal likability", "technical skill/trust", and "cares about me" were most significant positioning factors that contributed patient satisfaction. DISCUSSION This study shows that there are inconsistencies between nurse perceptions and patient perceptions of medical service attributes. Also, for service quality improvement, it is most important for nurses to understand what satisfiers, hygiene factors, and performance factors are through two-way communications. Patient satisfaction should be measured, and problems identified should be resolved for survival in intense competitive market conditions. Hence, patient satisfaction monitoring is now becoming a standard marketing tool for healthcare providers and its role is expected to increase.

  • PDF

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

The NCAM Land-Atmosphere Modeling Package (LAMP) Version 1: Implementation and Evaluation (국가농림기상센터 지면대기모델링패키지(NCAM-LAMP) 버전 1: 구축 및 평가)

  • Lee, Seung-Jae;Song, Jiae;Kim, Yu-Jung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.307-319
    • /
    • 2016
  • A Land-Atmosphere Modeling Package (LAMP) for supporting agricultural and forest management was developed at the National Center for AgroMeteorology (NCAM). The package is comprised of two components; one is the Weather Research and Forecasting modeling system (WRF) coupled with Noah-Multiparameterization options (Noah-MP) Land Surface Model (LSM) and the other is an offline one-dimensional LSM. The objective of this paper is to briefly describe the two components of the NCAM-LAMP and to evaluate their initial performance. The coupled WRF/Noah-MP system is configured with a parent domain over East Asia and three nested domains with a finest horizontal grid size of 810 m. The innermost domain covers two Gwangneung deciduous and coniferous KoFlux sites (GDK and GCK). The model is integrated for about 8 days with the initial and boundary conditions taken from the National Centers for Environmental Prediction (NCEP) Final Analysis (FNL) data. The verification variables are 2-m air temperature, 10-m wind, 2-m humidity, and surface precipitation for the WRF/Noah-MP coupled system. Skill scores are calculated for each domain and two dynamic vegetation options using the difference between the observed data from the Korea Meteorological Administration (KMA) and the simulated data from the WRF/Noah-MP coupled system. The accuracy of precipitation simulation is examined using a contingency table that is made up of the Probability of Detection (POD) and the Equitable Threat Score (ETS). The standalone LSM simulation is conducted for one year with the original settings and is compared with the KoFlux site observation for net radiation, sensible heat flux, latent heat flux, and soil moisture variables. According to results, the innermost domain (810 m resolution) among all domains showed the minimum root mean square error for 2-m air temperature, 10-m wind, and 2-m humidity. Turning on the dynamic vegetation had a tendency of reducing 10-m wind simulation errors in all domains. The first nested domain (7,290 m resolution) showed the highest precipitation score, but showed little advantage compared with using the dynamic vegetation. On the other hand, the offline one-dimensional Noah-MP LSM simulation captured the site observed pattern and magnitude of radiative fluxes and soil moisture, and it left room for further improvement through supplementing the model input of leaf area index and finding a proper combination of model physics.