• Title/Summary/Keyword: Size variation

Search Result 2,792, Processing Time 0.029 seconds

Implement of Hand Gesture Interface using Ratio and Size Variation of Gesture Clipping Region (제스쳐 클리핑 영역 비율과 크기 변화를 이용한 손-동작 인터페이스 구현)

  • Choi, Chang-Yur;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.121-127
    • /
    • 2013
  • A vision based hand-gesture interface method for substituting a pointing device is proposed in this paper, which is used the ratio and size variation of Gesture Region. Proposed method uses the skin hue&saturation of the hand region from the HSI color model to extract the hand region effectively. This method can remove the non-hand region, and reduces the noise effect by the light source. Also, as the computation quantity is reduced by detecting not the static hand-shape recognition, but the ratio and size variation of hand-moving from the clipped hand region in real time, more response speed is guaranteed. In order to evaluate the performance of the our proposed method, after applying to the computerized self visual acuity testing system as a pointing device. As a result, the proposed method showed the average 86% gesture recognition ratio and 87% coordinate moving recognition ratio.

Size Distribution and Source Identification of Airborne Particulate Matter and Metallic Elements in a Typical Industrial City

  • Ny, Mai Tra;Lee, Byeong-Kyu
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.9-19
    • /
    • 2010
  • The size distribution of airborne particulate matter (PM) and the concentrations of associated metallic elements were investigated in a busy urban region of a typical Korean industrial city. The PM concentrations measured during the spring, except for those in the size range of 1.1 to 2.1 ${\mu}m$, were slightly higher than the PM concentrations in the summer. Coarse particles contributed greatly to the variation in PM concentrations in the spring, while fine and submicron particles contributed largely to the variation in PM concentrations in the summer. The difference in size modes of the PM concentrations between spring and summer may be explained by the Asian dust effect and its accompanying wind direction and speed. Extremely high enrichment factors (EFs) values (6,971 to 60,966) for all of the size distributions in PM were identified for cadmium (Cd). High EFs values (12 to 907) were also identified for other heavy metals including Cr, Cu, Ni, Pb, Zn and Mn. Low EF values (0.29 to 8.61) were identified for Ca, K, Mg and Na. These results support the common hypothesis that most heavy metals in ambient PM have anthropogenic sources and most light metals have crustal sources. The results of principal components analyses and cluster analyses for heavy metals indicate that the principal sources of PM and metals were emissions from non-ferrous metal smelters, oil combustion, incinerators, vehicular traffic and road dust.

Effect of the Ni Catalyst Size and Shape on the Variation of the Geometries for the As-grown Carbon Coils

  • Jang, Chang-Young;Kim, Sung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • Carbon nanofilaments (CNFs) could be synthesized using $C_2H_2/H_2$ as source gases and $SF_6$ as an incorporated additive gas under thermal chemical vapor deposition system. Ni powders were used as the catalyst for the formation of the CNFs. During the initial deposition stage, the initiation of the CNFs on the Ni catalyst was investigated. The geometries of the as-grown CNFs on Ni catalyst were strongly dependent on the size and/or the shape of Ni catalyst. Small size catalyst (<150 nm in diameter) gives rise to the unidirectional growth of the CNFs. On the other hand, large size catalyst (150~500 nm), the bidirectional growth of the CNFs could be observed. Particularly, the well faceted parallelogram-shaped Ni catalyst could give rise to the bidirectional growth of the CNFs having the symmetrically opposite direction. Eventually, these bidirectional growths of CNFs were understood to form the well-developed carbon microcoils (CMCs). Based on these results, the optimal shape and the size of the Ni catalyst to form the CMCs were discussed.

Continuous Measurements of Size Separated Atmospheric Aerosol Number Concentration in Background Area (대기배경지역 에어로졸의 입경별 수농도 연속 측정)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2012
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan site, which is known as background area in Korea, from January to September 2011. The temporal variation and the size distribution of aerosol number concentration have been investigated. The entire averaged aerosol number concentration in the size range 0.25~32.0 ${\mu}m$ is about 252 particles/$cm^3$. The number concentration in small size ranges(${\leq}0.5{\mu}m$) are very higher than those in large size ranges, such as, the number concentration in range of larger than 6.5 ${\mu}m$ are almost zero particles/$cm^3$. The contributions of the number concentration to PM10 and/or PM2.5 are about 34%, 20.1% and 20.4% in the size range 0.25~0.28 ${\mu}m$, 0.28~0.30 ${\mu}m$ and 0.30~0.35 ${\mu}m$, respectively, however, the contributions are below 1% in range of larger than 0.58 ${\mu}m$. The monthly variations in the number concentration in smaller size range(<1.0 ${\mu}m$) are evidently different from the variations in range of larger than 1.0 ${\mu}m$, but the variations are appeared similar patterns in smaller size range(<1.0 ${\mu}m$), also the variations in range of larger than 1.0 ${\mu}m$ are similar too. The diurnal variations in the number concentration for smaller particle(<1.0 ${\mu}m$) are not much, but the variations for larger particle are very evident. Size-fractioned aerosol number concentrations are dramatically decreased with increased particle size. The monthly differences in the size-fractioned number concentrations for smaller size range(<0.7 ${\mu}m$) are not observed, however, the remarkable monthly differences are observed for larger size than 0.7 ${\mu}m$.

Investigating the underlying structure of particulate matter concentrations: a functional exploratory data analysis study using California monitoring data

  • Montoya, Eduardo L.
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.6
    • /
    • pp.619-631
    • /
    • 2018
  • Functional data analysis continues to attract interest because advances in technology across many fields have increasingly permitted measurements to be made from continuous processes on a discretized scale. Particulate matter is among the most harmful air pollutants affecting public health and the environment, and levels of PM10 (particles less than 10 micrometers in diameter) for regions of California remain among the highest in the United States. The relatively high frequency of particulate matter sampling enables us to regard the data as functional data. In this work, we investigate the dominant modes of variation of PM10 using functional data analysis methodologies. Our analysis provides insight into the underlying data structure of PM10, and it captures the size and temporal variation of this underlying data structure. In addition, our study shows that certain aspects of size and temporal variation of the underlying PM10 structure are associated with changes in large-scale climate indices that quantify variations of sea surface temperature and atmospheric circulation patterns.

THREE-DIMENSIONAL FINI6E ELEMENT ANALYSIS OF THE ENDOSSEOUS IMPLANT DESIGNS (삼차원 유한요소 해석에 의한 골내 임프란트의 구조에 관한 연구)

  • Hyun, Young-Keun;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.181-210
    • /
    • 1997
  • The stress distribution generated in the surrounding bone was calculated and compared for various geometry of the dental implants by means of the finite element methods. The models were designed to represent the screw type endosseous implants(varing the size, shape, direction of the screw thread and the angle of the body) with supporting bone and the cylinder type endosseous implants(varing the lower portion-Round type, tapered type) with supporting bone. Static mean bite forces were applied 100N vertically and 25N horizontally on the center of the implant and three dimensional finite analysis was undertaken using software ANSYS 5.1 Version. The result demonstrated that different implant shape leads to significant variations in stress distribution in the bone. In the case of variation of the screw size, direction and shape the implant model with normally directional and triangular screw implied lower stress than with upper directional or lower directional and quadrangular screw but among models a different screw size, within a variation of 0.2mm there was no meaningful difference in maximum stress. In the case of variation of angle of body the straight implied lower stress than the tapered. As a result of analysis of cylinder type, the implants with larger radius of curvature of the round form and larger diameter of the tapered form implied lower stress.

  • PDF

Size Variation and Cyclomorphosis of the Rotifer, Brachionus rotundiformis, Isolated from Cheju island, Korea

  • Song, Choon-Bok;Kim, Yeon-Hee;Lee, Je-Hee;Rho, Sum
    • Journal of Aquaculture
    • /
    • v.12 no.4
    • /
    • pp.267-274
    • /
    • 1999
  • A rotifer starin has been isolated from tide pools located near Sogwipo, Cheju Island and the effects of environmental factors (water temperature and salinity) and clonal differences have been examined with regard to size variation and cyclomorphosis. Adult female rotifers varied from 141.61 to $173.97 \mutextrm{m}$ in their mean lorica length under different rearing conditions in the laboratory and also had pointed anterior spines . Thus, this strain was classified as Brachionus rotundiformes. Mean lorica length tended to be smaller as rearing temperature increased although there were some exceptions. Statistical analysis indicated that lorica length was largely influenced by both clonal differences and rearing temperatures although the former as a genetic factor affected lorica length a little more than the latter did ; overall effect of salinity on lorica length was not statistically signicicant; furthermore, cyclomorphosis was also largely influenced by both clonal differences and rearing temperatures, but clonal differences as a genetic factor affected rotifer cyclomorphosis much more than temperature did.

  • PDF

Articulatory characteristics and variation of Korean laterals

  • Hwang, Young;Charles, Sherman;Lulich, Steven M.
    • Phonetics and Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • Lateral approximants are well known as having complex articulatory characteristics, which vary cross-linguistically, across speakers, and across utterances. However, less attention has been paid to the articulation of Korean laterals, which do not contrast with a rhotic and may thus exhibit greater-than-normal variability. The focus of this study is to investigate the general articulatory characteristics of the Korean lateral [l] as well as the articulatory variation using novel 3D ultrasound imaging methods. The results of this study revealed significant between-speaker variation and some vowel-dependent variation with regard to the articulation of the Korean lateral [l], which has not been reported previously. Even though all participants in this study showed an anterior occlusion, the place of articulation and the size of the occlusion varied greatly across speakers. The data also revealed that left-right asymmetry is present in the articulation of the Korean lateral. The individual variation of the Korean lateral [l] suggests that it has a large articulatory-acoustic space for variation, since it has no contrasting sound that causes perceptual confusion.

Effect of Reaction Factors on the Fabrication of Nano-Sized Indium Oxide Powder by Spray Pyrolysis Process (분무열분해공정에 의한 인듐 산화물 나노 분말 제조에 미치는 반응인자들의 영향)

  • Yu Jae-Keun
    • Journal of Powder Materials
    • /
    • v.11 no.6 s.47
    • /
    • pp.493-502
    • /
    • 2004
  • In this study, nano-sized indium oxide powder with the average particle size below 100 nm is fab-ricated from the indium chloride solution by the spray pyrolysis process. The effects of the reaction temperature, the concentration of raw material solution and the inlet speed of solution on the properties of powder were studied. As the reaction temperature increased from 850 to $1000^{\circ}C$, the average particle size of produced powder increased from 30 to 100 nm, and microstructure became more solid, the particle size distribution was more irregular, the intensity of a XRD peak increased and specific surface area decreased. As the indium concentration of the raw material solution increased from 40 to 350 g/l, the average particle size of the powder gradually increased from 20 to 60 nm, yet the particle size distribution appeared more irregular, the intensity of a XRD peak increased and spe-cific surface area decreased. As the inlet speed of solution increased from 2 to 5 cc/min., the average particle size of the powder decreased and the particle size distribution became more homogeneous. In case of the inlet speed of 10 cc/min, the average particle size was larger and the particle size distribution was much irregular compared with the inlet speed of 5 cc/min. As the inlet speed of solution was 50 cc/min, the average particle size was smaller and microstructure of the powder was less solid compared with the inlet speed of 10 cc/min. The intensity of a XRD peak and the variation of specific area of the powder had the same tendency with the variation of the average par-ticle size.

Unconscious Response Characteristics of Pupils in the Observation toward to Spatial Image (공간이미지를 향한 주시에 나타난 동공의 무의식적 반응 특성)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.136-144
    • /
    • 2018
  • The purpose of this study is to examined the unconscious response of the pupil in the observation toward the image in the eye-tracking experiments that target on a large complex cultural space. Twenty-five men participated in this experiment and the observation data were analyzed in seconds per minute on watching time. It could examine the unconscious response of information searching in the change of pupil size in the process of observing the space. The results could be defined as following several points. First, it was possible to outline the unconscious response characteristics of pupil by analyzing sudden changes in pupil size as total, cumulative, and individual. The response characteristics using frequency and time can be utilized as the analytical method to examine the degree of interest of spatial components according to the purpose of analysis in the future. Second, according to the over ${\pm}5%$ of cumulative variation rate on the pupil size change, during in the 60 seconds, the continuous pupil dilation was used 25.2 seconds in 8.8 rounds and the pupil reduction was used 18.0 seconds in 7.0 rounds. Third, when the variation rate of ${\pm}5%$ or more was regarded as the sudden changes on pupil size by individual variation, the pupil dilation was 7.2 rounds of 8.6 seconds and pupil reduction was 6.0 seconds in 5.0 rounds. This means that the pupil increases 9.3% in one expansion and decreases -8.5% in the reduction process. As regarding pupil changes as cumulative rate, it appeared high change rate on pupil reduction but it became higher on pupil dilation in individual.