• Title/Summary/Keyword: Size selectivity

Search Result 294, Processing Time 0.026 seconds

Capping Intercrystalline Defects of Polycrystalline UiO-66 Membranes by Polydimethylsiloxane Coating (폴리다이메틸실록산 코팅을 통한 다결정성 UiO-66 분리막의 비선택적 결정립계 결함 캡핑)

  • Ik Ji Kim;Hyuk Taek Kwon
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.71-75
    • /
    • 2023
  • In general, the presence of non-selective intercrystalline (grain boundary) defects in polycrystalline metal-organic framework (MOF) or zeolite membranes, which are known to be ca. 1 nm in size, causes lower membrane performance (selectivity) than the intrinsically expected. In this study we show that applying a thin polymeric coating of polydimethylsiloxane (PDMS) on a polycrystalline MOF membrane is effective to cap the non-selective intercrystalline defects and therefore improve membrane performance. To demonstrate the concept, first, polycrystalline UiO-66, one of Zr-based MOFs, membranes were prepared by an in-situ solvothermal growth. By controlling membrane growth condition with respect to growth temperature, we were able to obtain polycrystalline UiO-66 membranes at 150 ℃ with intercrystalline defects of which the quantity is not significant, so it can be plugged by the suggested PDMS deposition. Second, their performances were compared before and after the PDMS deposition. As expected, the PDMS deposition ended up with a noticeable increase in CO2/N2 ideal selectivity from 6 to 14, indicating successful intercrystalline defect plugging. However, the enhancement in CO2/N2 selectivity was accompanied by a significant reduction in CO2 permeance from 5700 to 33 GPU because the PDMS deposition not only plugs defects but also forms a continuous coating on membrane surface, adding an additional transport resistance.

Complexation of Pyridino-Azacrown Ethers with Alkali Metal Ions in N,N-Dimethylformamide (N,N-디메틸포롬아미드 용액에서의 알칼리금속이온과 피리디노-아자크라운에테르와의 착물화 반응)

  • Kim, Dong Won;Shin Young-Kook;Kim Chang Suk;Oh Je Jik;Jeon Young Shin;Kim, Tae Seung
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.669-673
    • /
    • 1992
  • The stability constants, K for the complexation of alkali metal cations(Li^+, Na^+, K^+, Rb^+, and Cs^+) with both 4,5: 13,14-dibenzo-6,9,12-triaza-bicyclo [15,3,1] heneicosa-1 (21),7,19-trioxa-2,16-dione (DBPDA) and 6,9,12-trioxa-3,15,21-triaza bicyclo [15,3,1] heneicosa-1 (21),17,19-triene-2,16-dione (PDA) in N,N-Dimethylformamide (DMF) were determined conductomatically at various temperatures. At all the experiment temperatures, the K value sequences of the alkali metal ions with DBPDA and PDA are Cs^+ > K^+ > Rb^+ > Li^+ > Na^+ and Cs^+ > K^+ > Rb^+ > Li^+ > Na+, respectively. The K values for DBPDA are larger those of PDA for alkali metal ions. The widely recounted "hole-size-selectivity" principle is not applicable to these complexation systems. From the K values obtained at different temperatures, {\delta}H and T{\delta}S for these complexation reactions were determined. The enthalpy change plays principal important role in the complex formation by DBPDA. However, in the case of PDA, the entropy change also contributes to its complex formation.

  • PDF

Spatial Partitioning for Query Result Size Estimation in Spatial Databases (공간 데이터베이스에서 질의 결과 크기 추정을 위한 공간 분할)

  • 황환규
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.2
    • /
    • pp.23-32
    • /
    • 2004
  • The query optimizer's important task while a query is invoked is to estimate the fraction of records in the databases that satisfy the given query condition. The query result size estimation in spatial databases, like relational databases, proceeds to partition the whole input into a small number of subsets called “buckets” and then estimate the fraction of the input in the buckets. The accuracy of estimation is determined by the difference between the real data counts and approximations in the buckets, and is dependent on how to partition the buckets. Existing techniques for spatial databases are equi-area and equi-count techniques, which are respectively analogous in relation databases to equi-height histogram that divides the input value range into buckets of equal size and equi-depth histogram that is equal to the number of records within each bucket. In this paper we propose a new partitioning technique that determines buckets according to the maximal difference of area which is defined as the product of data ranges End frequencies of input. In this new technique we consider both data values and frequencies of input data simultaneously, and thus achieve substantial improvements in accuracy over existing approaches. We present a detailed experimental study of the accuracy of query result size estimation comparing the proposed technique and the existing techniques using synthetic as well as real-life datasets. Experiments confirm that our proposed techniques offer better accuracy in query result size estimation than the existing techniques for space query size, bucket number, data number and data size.

Construction of New P4-Derived Vector Plasmid Containing Tetracyclin Resistance Marker for the Bacteriophage P2-P4 System (박테리오파아지 P2-P4 시스템을 위한 tetracyclin resistance marker 함유 P4 유도체 벡터 플라스미드 조성)

  • Kim, Kyoung-Jin
    • Korean Journal of Microbiology
    • /
    • v.39 no.2
    • /
    • pp.118-122
    • /
    • 2003
  • To develop vector plasmid for the bacteriophage P2-P4 system which is a useful experimental tool for the study of viral capsid assembly, we constructed a new P4-derived vector plasmid starting from P4 ash8 sid71 With recombinant DNA technology, a portion of P4 genome was deleted and tetracyclin resistance gene (terR) was introduced into P4 genome to give P4 selectivity. Resulting P4 ash8(sid71) terR was 12.09 kb long and could be converted to a viable bacteriophage with P2 infection. The burst size of induced bacteriophage form of P4 ash8(sid71) terR was determined. The CsCl buoyant equilibrium density gradient experiment of new P4 derivative suggested the upper limit of packaging capacity in P2-size head.

Design of a Narrow-Band Bandpass Filter Using Microstrip Open-Loop Resonators With Coupled and Crossing Lines (결합 및 교차 선로를 갖는 마이크로스트립 개방루프 공진기를 이용한 협대역 대역통과 여파기 설계)

  • 안승현;이영구;이문수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.1011-1016
    • /
    • 2001
  • In this paper, a narrow-band bandpass filter using microstrip open-loop resonators with coupled and crossing lines is designed and fabricated. This filter has many advantages such as compact in size, low weight and the characteristic of the elliptic-function narrow-band bandpass filtering. The configuration consists of two identical microstrip open loop resonators, coupled line and crossing line. By using open loop resonators, the size of the filter can be reduced about 50% compared with the ring resonators. A crossing line gives two notchs in the stopband, which have sharp selectivity in the passband. Centered at 2.455GHz, the calculated microstrip bandpass filter shows a bandwidth of 1.22%, which makes it very attractive for application in the wireless LAN. The filter is fabricated by photo-etching process. The fabricated bandpass filter shows that the bandwidth is 0.85% for 2.458GHz and the size is only $2.6cm\times1cm$.

  • PDF

One-dimensionally Ordered Array of Co and Fe Nanoclusters on Carburized-W(110) via Template Assisted Self-Assembly

  • Kim, Ji-Hyun;Yang, Serlun;Kim, Jae-Sung;Lukashev, Pavel;Rojas, Geoffrey;Enders, Axel;Sessi, Violetta;Honolka, Jan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.135-136
    • /
    • 2012
  • Carbon atoms near the surface of W(110) induce reconstructions such as $R(15{\times}12)$ -C/W(110) which consists of two characteristic parts, one square shaped and bright protrusion and two smaller ones. In the atomic resolution STM image, the bigger protrusion shows the periodicities of clean W(110), indicating that it is almost carbon poor region. The smaller protrusion contains hexagonal carbide surface layer of ${\alpha}$-W2C on W(110). Employing this carburized W(110) as templates, we grow Co and Fe clusters of less than ten atoms. Due to the selectivity of bonding sites, growth of larger cluster is highly unfavorable for Co and the size of clusters is very uniform. Since Co atoms prefer to sit on the bigger protrusion rather than smaller one, Co cluster can be arranged one-dimensionally in $R(15{\times}12)$-C/W(110) with quite uniform size distribution. However, Fe clusters sit on both sites without favored site, but still with uniform size distribution. On the other hand, Fe clusters can be grown with quasi one-dimensional order in $R(15{\times}3)$-C/W(110), which consists of only smaller protrusions. We investigate the magnetic properties of the ordered nano-sized clusters. Experiments using XMCD reveals little magnetic moment of Co cluster on $R(15{\times}12)$-C/W(110). This observation is consistent with the predictions of our first principles calculations that small Co clusters can be nonmagnetic or antiferromagnetic with low mean magnetic moment per atom.

  • PDF

The use of HRSEM to characterize new and aged membranes in drinking water production

  • Wyart, Y.;Nitsche, S.;Chaudanson, D.;Glucina, K.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.251-266
    • /
    • 2011
  • This work deals with the use of High Resolution Scanning Electron Microscopy (HRSEM) to verify ultrafiltration membrane selectivity at the end of the production line as well as membrane ageing. The first part of this work is focused on new membranes. It is shown that it is better to use sputtering metallization than vacuum deposition, as this latter technique entails thermal damage to the skin layer. Moreover, the impact of the metallization layer on the determination of the membrane pore size is studied and it is observed that no impact of the metallization step can be clearly defined for a metallization layer ranging from 3 to 12 nm. For example, an average pore size of 16.9 nm and a recovery rate of 6.5 % are observed for a 150 kDa cellulose acetate membrane. These results are in agreement with those given by the manufacturer: pore size ranging from 10 to 15 nm and recovery rate ranging from 5 to 10 %. The second part of this work focuses on the study of membrane ageing. A PVDF hollow fibre membrane is studied. It is shown that a 65 % decrease in the permeate flux can be linked to a decrease in the number of pores at the surface of the membrane and a decrease in the recovery rate. In conclusion, a mapping of the pores is performed for several new hollow fibre membranes used to produce drinking water, made of different materials, with different geometries and molecular weight cut-off. These results provide reference data that will help better understand the phenomena of membrane fouling and membrane ageing.

Effect of Composition of γ-Al2O3/SiO2 Mixed Support on Fischer-Tropsch Synthesis with Iron Catalyst (철 기반 촉매의 Fischer-Tropsch 합성에서 γ-Al2O3/SiO2 혼합 지지체 조성의 영향)

  • Min, Seon Ki;No, Seong-Rae;You, Seong-sik
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.436-442
    • /
    • 2017
  • Fischer-Tropsch synthesis is the technology of converting a syngas (CO+$H_2$) derived from such as coal, natural gas and biomass into a hydrocarbon using a catalyst. The catalyst used in the Fischer-Tropsch synthesis consists of active metal, promoter and support. The types of these components and composition affect the reaction activity and product selectivity. In this study, we manufactured an iron catalyst using ${\gamma}-Al_2O_3/SiO_2$ mixed support (100/0 wt%, 75/25 wt%, 50/50 wt%, 25/75 wt%, 0/100 wt%) by an impregnation method to investigate how the composition of ${\gamma}-Al_2O_3/SiO_2$ mixed support effects on the reaction activity and product selectivity. The physical properties of catalyst were analyzed by $N_2$ physical adsorption and X-Ray diffraction method. The Fischer-Tropsch synthesis was conducted at $300^{\circ}C$, 20bar in a fixed bed reactor for 60h. According to the results of the $N_2$ physical adsorption analysis, the BET surface area decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the pore volume and pore average diameter increase as the composition of ${\gamma}-Al_2O_3$ decreases except for the composition of ${\gamma}-Al_2O_3/SiO_2$ of 50/50 wt%. By the results of the X-Ray diffraction analysis, the particle size of ${\alpha}-Fe_2O_3$ decreases as the composition of ${\gamma}-Al_2O_3$ decreases. As a result of the Fischer-Tropsch synthesis, the CO conversion decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the selectivity of C1-C4 decreases until the composition of ${\gamma}-Al_2O_3$ was 25 wt%. In contrast, the selectivity of C5+ increases until the composition of ${\gamma}-Al_2O_3$ is 25 wt%.

Multiplexed, Stack-wise, and Parallel Recording of Near-field Binary Holograms (근접장 이진 홀로그램의 다중화, 다층화 및 병렬 저장)

  • Kim, Kyoung-Youm;Kang, Jin-Gu;Lee, Byoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.47-49
    • /
    • 2001
  • We present experimental results on the multiplexed and stack-wise recording of near-field holograms. Experiments on angular multiplexing show that the angular selectivity of near-field hologram is better than that of the conventional hologram Experiments on stack-wise recording prove that near fields originated from sub-diffraction-limit-size objects could be stored in a photorefractive crystal at 2 mm apart from the crystal surface. In addition, to improve the data access and transfer time silicon nano-aperture array was introduced and applied to the near-field holographic storage.

  • PDF

Effect of Crown Ring Size and Upper Moiety on the Extraction of s-Block Metals by Ionizable Calixcrown Nano-baskets

  • Mokhtari, Bahram;Pourabdollah, Kobra
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3979-3990
    • /
    • 2011
  • Eight ionizable nano-baskets of cone 25,26-di(carboxymethoxy)calix[4]arene-crown-3,4,5,6 were synthesized and were verified by $^1H$ and $^{13}C$ NMR spectroscopy, IR spectroscopy and elemental analysis. The competitive solvent extractions of alkali and alkaline earth metal cations were studied using such nano-baskets. The novelty of this study is including three binding units of calixarene's bowl, crown ether's ring and electron-donor ionizable moieties in a unique scaffold to assess the binding tendency towards the cations. The objective of this work is to study the extraction efficiency, selectivity and $pH_{1/2}$ of such complexes. The result of solvent extraction experiments indicated that these compounds were effective extractants of alkali and alkaline earth metal cations. Their selectivities were greatly influenced by the acidity of solution and the conformations of the calixcrown. One conformer was selective to $Na^+$ in pH ${\geq}$ 4, while the other was highly selective to $Ba^{2+}$ in pH 6 and upper.