• Title/Summary/Keyword: Size of contact area

Search Result 213, Processing Time 0.021 seconds

A Study on the Contact Error of Dial Gauge (DIAL GAUGE 측정자의 접촉오차에 관한 연구)

  • 강석수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.138-143
    • /
    • 2000
  • In order to maintain the faith and accuracy with precision of machinery, it is recently required the precise comprehension about approach which is appeared in the contact area between two bodies, because approach affects the static stiffness and dynamic characteristic of contact area. This study applied H. Hertz's circle contact area theory as much lower measuring force. It is measured approach influenced by various factors which were concerned with contact errors like material, form of two bodies, using calibration tester. As a result, the following conclusion can be obtained. 1) The approach appears greatly in order of carbon steel(SM20C), aluminum(A601-T6) and high density polyethylene(5305E) 2) The approach appears in order of concave, disc, convex form, in the ration of contact area size by the difference of curvature.

  • PDF

Nano/Micro Friction with the Contact Area (접촉 면적에 따른 나노/마이크로 마찰 특성)

  • Yoon Eui-Sung;Singh R. Arvind;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.209-215
    • /
    • 2005
  • Nano/micro friction with the contact area was studied on Si-wafer (100) and diamond-like carbon (DLC) film. Borosilicate balls of radii $0.32{\mu}m,\;0.5{\mu}m,\;1.25{\mu}m\;and\;2.5{\mu}m$ mounted on the top of AFM tip (NPS) were used for nano-scale contact and Soda Lime glass balls of radii 0.25mm, 0.5mm, 1mm were used for micro-scale contact. At nano-scale, the friction between ball and surface was measured with the applied normal load using an atomic force microscope (AFM), and at micro scale it was measured using ball-on flat type micro-tribotester. All the experiments were conducted at controlled conditions of temperature $(24\pm1^{\circ}C)$ and humidity $(45\pm5\%)$. Friction was measured as a function of applied normal load in the range of 0-160nN at nano scale and in the range of $1000{\mu}N,\; 1500{\mu}N,\;3000{\mu}N\;and\;4800{\mu}N$ at micro scale. Results showed that the friction at nano scale increased with the applied normal load and ball size for both kinds of samples. Similar behavior of friction with the applied normal load and ball size was observed for Si-wafer at micro scale. However, for DLC friction decreased with the ball size. This difference of in behavior of friction in DLC nano- and microscale was attribute to the difference in the operating mechanisms. The evidence of the operating mechanisms at micro-scale were observed using scanning electron microscope (SEM). At micro-scale, solid-solid adhesion was dominant in Silicon-wafer, while plowing in DLC. Contrary to the nano scale that shows almost a wear-less situation, wear was prominent at micro-scale. At nano- and micro-scale, effect of contact area on the friction was discussed with the different applied normal load and ball size.

Study on the Enhancement of the Uniform Contact Technology for Large Scale Imprinting with the Design of Vacuum Gripping Pad (진공척 흡착패드 형태에 따른 대면적 임프린팅 균일 접촉 향상 연구)

  • Jang, Si-Youl
    • Tribology and Lubricants
    • /
    • v.24 no.6
    • /
    • pp.326-331
    • /
    • 2008
  • The contact surfaces between mold and target should be in parallel for a proper imprinting process. However, large size of contacting area makes it difficult for both mating surfaces (mold and target planes) to be in all uniform contact with the expected precision level in terms of thickness and position. This is caused by the waviness of mold and target although it is very small relative to the area scale. The gripping force for both mold and target by the vacuum chuck is other major effect to interrupt the uniform contact, which must be avoided in imprinting mechanism. In this study, the cause of non-conformal contact mechanism between mold and target is investigated with the consideration of deformation due to the vacuum gripping for the size $470{\times}370\;mm^2$ LCD panel.

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.

Effect of Particle Size of Ceria Coated Silica and Polishing Pressure on Chemical Mechanical Polishing of Oxide Film

  • Kim, Hwan-Chul;Lim, Hyung-Mi;Kim, Dae-Sung;Lee, Seung-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.167-172
    • /
    • 2006
  • Submicron colloidal silica coated with ceria were prepared by mixing of silica and nano ceria particles and modified by hydrothermal reaction. The polishing efficiency of the ceria coated silica slurry was tested over oxide film on silicon wafer. By changing the polishing pressure in the range of $140{\sim}420g/cm^2$ with the ceria coated silica slurries in $100{\sim}300nm$, rates, WIWNU and friction force were measured. The removal rate was in the order of 200, 100, and 300 nm size silica coated with ceria. It was known that the smaller particle size gives the higher removal rate with higher contact area in Cu slurry. In the case of oxide film, the indentation volume as well as contact area gives effect on the removal rate depending on the size of abrasives. The indentation volume increase with the size of abrasive particles, which results to higher removal rate. The highest removal rate in 200 nm silica core coated with ceria is discussed as proper combination of indentation and contact area effect.

Estimation of Heat Generation in Multi-Contact Connector for Superconducting Magnet Application (초전도자석 시스템 응용을 위한 멀티-컨텍 커넥터의 열 발생 특성 평가)

  • Kim, M.S.;Choi, Y.S.;Kim, D.L.;Lee, Y.A.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2012
  • Current leads are one of the important components for carrying the current to the coil in the superconducting magnet system. Heat leakage through the current lead is the major factor of entire heat load in the cryogenic system because current leads carry the current from room temperature to near 4 K, connecting thermally each other. Therefore, minimization heat load through current lead can reduce the operating temperature of superconducting magnet. The semi-retractable current lead, composed of multi-contact connector and HTS element, is one of good options. Comprehension of Multi-contact connector's structure, contact resistance and heat generation is essential for estimating heat generation in current leads. Multi-contact connector has several louvers inside of socket and the shape, number, size of louvers are different with the size of connector. Therefore contact area, current path and contact resistance are also different. In this study, the contact resistance in multi-contact connector is measured using the electrical power as a function of connector's size and temperature. Also, the unique correlation of electrical contact resistance is derived and heat generation is estimated for superconducting magnet application.

Pore size effects of adhesion and friction for nanohoneycomb structures in AFM (원자현미경에서 나노허니컴 구조물의 홀 사이즈에 따른 점착 및 마찰 거동 분석)

  • Choi, Duk-Hyun;Lee, Pyung-So;Lee, Kun-Hong;Park, Hyun-Chul;Hwang, Woon-Bong
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.129-132
    • /
    • 2005
  • This study analyzes the behavior of adhesion and friction according to the pore size of nanohoneycomb structures in atomic force microscope (AFM). Anodic aluminum oxide (AAO) films are fabricated as nanohoneycomb structures. According to the pore diameters of the nanohoneycomb structures, the adhesive forces and the frictional coefficients arc obtained in AFM, and the behaviors are analyzed in the view of the contact area between the sphere particle and nanohoneycomb substrate. The effective Young's moduli of the nanohoneycomb structures are measured from the nanoindentation tests, and the contact areas at zero applied load are calculated by combining the porosity of the nanohoneycomb structures and the contact radius determined from JKR and DMT theory.

  • PDF

3D Elastic Contact Analysis of Sharkskin Surface Pattern (상어 표피 형상의 3차원 탄성접촉해석)

  • Kim, Tae Wan
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.297-302
    • /
    • 2012
  • We conducted 3D elastic contact analysis of a sharkskin surface pattern for the characteristic assessment of biomimetic shark skin structure pattern for engineering applications. Rough sharkskin surfaces of similar size with real shark skin scales are generated numerically. Under the assumption of the contact of a plate on the generated sharkskin surface, contact performances such as contact pressure, real contact area, and surface separation are evaluated.

Analysis of the effect of changes in the gate design on cell size and density in Mucell injection molding (초미세 발포성형에서 게이트의 형상 변화에 따른 셀의 크기 및 밀도에 대한 영향도 분석)

  • Jae Hyuk Choi
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.64-69
    • /
    • 2023
  • This paper explores the impact of gate shape changes on the size and density of foamed cells in microcellular foam injection molding. Five different gate shapes were examined while varying the amount of nitrogen gas(N2) injected for foaming. Analysis of the results showed that while average values did not change significantly, deviation values decreased by approximately 65% for cell size and 56% for density when 3.5wt% of nitrogen gas was injected in the film gate. Further analysis was conducted to verify this phenomenon, revealing that the contact area between the gate and product had the greatest impact. Our findings indicate that to ensure uniform generation of foamed cells in microcellular foaming product design, a gate with a wide contact area should be secured.

  • PDF

Apical root canal cleaning after preparation with endodontic instruments: a randomized trial in vivo analysis

  • Fornari, Volmir Joao;Hartmann, Mateus Silveira Martins;Vanni, Jose Roberto;Rodriguez, Rubens;Langaro, Marina Canali;Pelepenko, Lauter Eston;Zaia, Alexandre Augusto
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.38.1-38.10
    • /
    • 2020
  • Objectives: This study aimed to evaluate vital pulp tissue removal from different endodontic instrumentation systems from root canal apical third in vivo. Materials and Methods: Thirty mandibular molars were selected and randomly divided into 2 test groups and one control group. Inclusion criteria were a positive response to cold sensibility test, curvature angle between 10 and 20 degrees, and curvature radius lower than 10 mm. Root canals prepared with Hero 642 system (size 45/0.02) (n = 10) and Reciproc R40 (size 40/0.06) (n = 10) and control (n = 10) without instrumentation. Canals were irrigated only with saline solution during root canal preparation. The apical third was evaluated considering the touched/untouched perimeter and area to evaluate the efficacy of root canal wall debridement. Statistical analysis used t-test for comparisons. Results: Untouched root canal at cross-section perimeter, the Hero 642 system showed 41.44% ± 5.62% and Reciproc R40 58.67% ± 12.39% without contact with instruments. Regarding the untouched area, Hero 642 system showed 22.78% ± 6.42% and Reciproc R40 34.35% ± 8.52%. Neither instrument achieved complete cross-sectional root canal debridement. Hero 642 system rotary taper 0.02 instruments achieved significant greater wall contact perimeter and area compared to reciprocate the Reciproc R40 taper 0.06 instrument. Conclusions: Hero 642 achieved higher wall contact perimeter and area but, regardless of instrument size and taper, vital pulp during in vivo instrumentation is not entirely removed.