• Title/Summary/Keyword: Size of Particles

Search Result 4,012, Processing Time 0.029 seconds

Effect of Particle Size Distribution of Binder on the Rheological Properties of Slag Cement Pastes (결합재의 입도분포가 슬래그 시멘트 페이스트의 유동 특성에 미치는 영향)

  • Hwang, Hae-Jeong;Lee, Seung-Heun;Lee, Won-Jun
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.1 s.296
    • /
    • pp.6-11
    • /
    • 2007
  • The rheological properties of slag cement pastes by effect of particle size distribution of binder were investigated using a Rheostress 1 rheometer (Haake) with a cylindrical spindle and the relationship between fluidity particle size distribution using the Rosin-Rammler equation. Samples are combined the two types of slag powder and OPC, fine slag particles sized Elaine specific surface area $8,000cm^2/g$, coarse slag particles sized Elaine specific surface area $2,000cm^2/g$, intermediate OPC particles $3,450cm^2/g$, used to search for the combination that would yield the best quality product. The all flow curves which were measured by rheometer showed hysterisis and could be classified into 4 types. When the combination was based on a ratio of 15-20 vol% fine particles, 40-50 vol% intermediate particles, 30-40 vol% coarse particles of the total volume, a high fluidity and low yield-strength was achieved. The Rosin-Rammler function can explain aboved correlation flow curve types. On type 1, the n-value had a correlation with plastic viscosity however the blend of type 2 and 3 showed consistent n-value regardless of plastic viscosity. In addition, the blend in type 4 tended to a rise in fluidity according to the increase of the n-value.

Analysis of Fine Particle Transfer and Shear Strength Increase Using PFC in Permeation Grouting (PFC를 이용한 침투그라우팅시 미세입자의 이동 및 전단강도증가 해석)

  • Lee, Wan-Ho;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.49-58
    • /
    • 2007
  • Numerical experiments using a distinct element code (PFC3D) were carried out for the analysis of grout-material transfer in soil layers and also for the analysis of increase in mechanical strength after permeation grouting. For rapid analysis, up-scaling analysis in length scale was adopted, and the following observations were made from the numerical experiments. Firstly, the relative size of grout material with respect to the in situ soil particles controlled the transfer distance of the grout particles. When the size of grout particle was 0.2 to 0.25 times of the in situ soil particles, clogging of pore spaces among the in situ soil particles occurred, resulting in restricted propagation of grout particles. It was also found that there was a threshold value in the size of grout particle. Below the threshold value, the transfer distance of the grout particle did not increase with the decrease of particle size of the grout material. Secondly, the increase in cohesion and internal friction angle was observed in the numerical specimen with grouting treatment, but not with the untreated specimen.

Development of a Real-time Monitoring Device for Measuring Particulate Matter

  • Kim, Dae Seong;Cho, Young Kuk;Yoon, Young Hun
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, we have developed a real-time monitoring device for measuring $PM_{10/2.5/1}$ of ambient aerosol particles. The real-time PM (Particulate Matter) monitor was based on the light scattering method and had 16 channels in particle size. The laboratory and field tests were carried out to evaluate the performance of the PM monitor developed. Arizona Road Dust particles ranging from diameter of 0.1 to $20{\mu}m$ were generated as test particles in the laboratory test. The field test was carried out at the Seoul Meteorological Observatory. We can obtain the particle size and number concentration (particle size distribution) only from the real-time PM monitor developed. Therefore, the average density of aerosol particles was used to obtain the PM data from the particle size distribution. The $PM_{10/2.5/1}$ results of the PM monitor were compared with the data of the Grimm Dust Monitor (Model 1.108) and a beta ray gauge (Thermo Fisher Scientific). As a result, it was shown that the $PM_{10/2.5/1}$ results obtained by the real-time PM monitor agreed well with the data of the reference devices, and overall, the real-time PM monitor could be used as a PM monitoring device for real-time monitoring of the ambient particles.

Neutral Deinking of Photocopied Papers with Nonionic Surfactants (비이온 계면활성제를 이용한 복사고지의 중성탈묵)

  • 정영재;이학래
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.58-67
    • /
    • 2001
  • MOW (Mixed Office Waste) mainly consisted of photocopied paper is being recycled to produce tissue or fine paper products. Toner particles that are fused and set on paper surface in photocopying process turns into large and plate-shaped particles after repulping which prevents them to be removed effectively in flotation deinking. The immediate purpose of this study is to find the effective deinking technology that increases the recycling potential of photocopied papers for manufacturing tissue and fine paper products. In this study the effects of pulping temperature and the type of hydrophobic groups of nonionic surfactants on the deinking efficiency of photocopied paper has been investigated. Particle size distribution of the toner particles after pulping and flotation, brightness, yield and ash removal were investigated. The size of toner particles after pulping increased as the pulping temperature was increased. When pulping at the low temperature finer toner particles were generated, however, greater amount of toner particles was found to attach to the fiber. When the pulping temperature was greater than Tg of the toner, the amount of coarse hairy particles increased. When nonionic surfactants with a double bond in hydrophobic groups were used, toner removal efficiency, brightness and ash removal were increased. As the addition level of surfactant was increased, yield decreased rather sharply without improving brightness.

  • PDF

The Effect of the Activation of Phosphoric Ester Cellulose Particles on the Electrotheological Properties of Anhydrous ER Fluids (인산 에스테르 반응 셀룰로오스 미립자의 활성화가 비수계 ER 유체의 전기유변학적 특성에 미치는 영향)

  • 안병길;최웅수;권오관;문탁진
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.7-16
    • /
    • 1998
  • The electrorheological (ER) behavior of suspensions in silicone oil of phosphoric ester cellulose powder (average particle size: 17.77 $\mu$m) was investigated at room temperature with electric fields up to 2.5 KV/mm. For development of anhydrous ER suspensions using at wide temperature range, we aimed to know the effect of activation of phosphoric ester cellulose particles on the ER activities. As a first step, the anhydrous ER suspensions mixing with the phosphoric ester cellulose particles which were treated with 2M phosporic acid and 4M urea were measured. After activating the anhydrous ER suspensions at 12$0^{\circ}C$, not only the analysis of dispersing cellulose particles which were reacted by phosphoric ester but also the electrorheological characteristics of ER suspensions such as dielectric constant, current density, electrical conductivity and rheological properties were studied. From the experimental results, the activation of phosphoric ester cellulose particles had an influence on the ER properties of anhydrous ER suspensions. As the activation time went by, the size and number of dispersing particles, the electrical properties and the initial apparent viscosity $(η_0)$ of ER suspensions were increased till the activation time passed 5 hours. Also, it was possible, the electrorheological effect $($\tau$/$\tau$_0)$ of ER fluids was grown by the activation of phosphoric ester cellulose particles.

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

Synthesis of Uniform Cu Particles by Hydrazine Reduction from Copper Sulfate Solution (황산동 수용액으로부터 hydrazine 환원에 의한 Cu 미립자의 합성)

  • Yu, Yeon-tae;Choi, Young-yoon
    • Korean Journal of Materials Research
    • /
    • v.13 no.8
    • /
    • pp.524-530
    • /
    • 2003
  • In order to prepare the uniform copper particles from copper sulfate solution by using hydrazine as a reduction agents, the reduction behavior of copper particles from copper sulfate was investigated in detail at room temperature by the observation of reaction products. The effects of $NH_4$OH and $Na_4$$P_2$$O_{7}$ on the formation of uniform copper particles were discussed. ($NHCu_3$)$_4$$SO_4$was completely formed at over pH 11 by adding $NH_4$OH in copper sulfate solution. The fine $Cu_2$O with the particle size of 50 nm was produced in the initial reduction process of (NH$Cu_3$)$_4$$SO_4$solution with $Na_4$$P_2$$O_{ 7}$ and then the Cu$_2$O was converted into copper particles by inserting additional hydrazine. When Cu(NH$_3$)$_4$SO$_4$solution with $Na_4$$P_2$$O_{ 7}$ was reduced at $80^{\circ}C$ by hydrazine, the highly dispersed copper particles with the particle size of about 0.8 $\mu\textrm{m}$ was obtained.

Study on Size Distribution of Total Aerosol and Water-soluble tons During an Asian Dust Storm Event at Jeju Island (황사기간중 제주지역의 에어로졸과 수용성이온의 크기분포)

  • Park Seong-Hun;Song Chang-Byeong;Kim Min-Cheol;Gwon Sun-Park;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.159-160
    • /
    • 2002
  • Soil dust particles transported from loess regions of the Asian continent, called Asian dust, highly influences the air quality of north-eastern Asia and the northern Pacific Ocean. The effects of these dust storms, on the chemical composition of atmospheric aerosol particles with different size, was investigated. Measurements of size distributions of total aerosol and major ion species were carried out on Jeju Island, Korea. (omitted)

  • PDF

Decrease in the Particle Size of Paclitaxel by Increased Surface Area Fractional Precipitation (표면적이 증가된 분별침전에 의한 paclitaxel의 입자 크기 감소)

  • Lee, Ji-Yeon;Kim, Jin-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.2
    • /
    • pp.157-162
    • /
    • 2012
  • In this study, we have for the first time applied increased surface area fractional precipitation in order to decrease the particle size of the anticancer agent paclitaxel from plant cell cultures. When compared with the case where no surface area increasing material was employed, the addition of ion exchange resin as a surface area increasing material resulted in a considerable decrease in the size of the paclitaxel precipitate. When ion exchange resin was used, the paclitaxel particles were four to five times smaller, having less than a 20 ${\mu}m$ radius, than those obtained in the absence of ion exchange resin. This is presumably because the growth of paclitaxel particles was impeded by the addition of ion exchange resin. The size of the paclitaxel precipitate also depended on the material used to increase the surface area, a result considered to be due to differences in the affinity between the particular ion exchange resin used and the paclitaxel particles. The yield of paclitaxel was significantly improved when ion exchange resin was used as a material to increase surface area. Paclitaxel, with a reduced particle size due to the addition of a surface area increasing material during the fractional precipitation process, is believed to be particularly useful for practical applications of the drug.

Quantitative characteristics of particle size distribution by the wear mode transition (마모유형 천이에 따른 입자크기분포의 정량적 특성)

  • 공호성;권오관
    • Tribology and Lubricants
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 1986
  • Wear simulation test have been conducted in mild, severe and transient wear regions by a four-ball wear tester. Wear particles are separatively deposited by the RPD technique, and quantitatively analysed in terms of wear particles size distribution. Characteristics of the wear particle size distribution are compare to the results of wear tests through both weibull parameters and center moment method of the weibull distribution function.