• Title/Summary/Keyword: Size deviation

Search Result 685, Processing Time 0.02 seconds

A Distcussion on the Size Deviation Test of Raw Silk (生絲纖度檢査規定에 關한 考察)

  • Choi, Jin-Sub
    • Journal of Sericultural and Entomological Science
    • /
    • v.25 no.1
    • /
    • pp.44-50
    • /
    • 1983
  • The study was carried out to suggest on opinion of the standardization of size deviation in the existing raw silk testing method. 1. The present grade A of size deviation stipulates 4.61 to 5.80 of standard deviation for 50 to 69 denier of mean value, however, the 5.80 standard deviation with the mean values of 50 and 69 denier belong to different distribution. 2. It is reasonable that the variation coefficients of grade 2A should be lower than that of grade A. However, the present testing method shows larger variation in grade 2A than in grade A. This is illustrated 9.00 for 69 denier in grade 2A and 8.41 for 70 denier in grade A. 3. The size deviation value compares the quality of raw silk with different mean value. Therefore, the standard deviation is recommended to be replaced by the C.V. value in determining the grade of silk. 4. The C.V. have a tendency to increase with lower grades below 6A for the size deviation below 33 denier with some inconsistencies. The figures should be adjusted so that the C.V. inconsistencies size deviation below 33 denier will be corrected. 5. The standard deviation increases with size under the same grade for the size deviations above 33 denier, however, the C.V. does not vary greatly with size deviation. 6. To rectify the above-mentioned inconsistencies the C.V. conversion and curvilinear regresion correction is recommended to improve the present silk testing method 7. The table of size deviation standard are as follows: Suggested standard of size deviation, unit: C.V. Value

  • PDF

NASAL ASYMMETRY AFTER PRIMARY OPERATIONS IN PATIENTS WITH UNILATERAL CLEFT LIP (일차 토순 수술후의 코입부위의 심미적 평가 제1보 코의 비대칭성)

  • Min, Byong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.390-395
    • /
    • 1994
  • The author evaluated the nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs. The results are as follows : 1. Nasal deviation angle is average 2.98+3.01 degree(ranged from 0 to 10 degree), significantly different from control group(p<0.05). 2. Nasal deviation angle is average 5.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 3. Difference in nostril size between cleft and noncleft side is 2.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 4. Nasal attractiveness analysis shows higher points in difference in nostril size, nasal deviation, nasal form in that order. 5. Nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs is related with Nasal deviation angle, Nasal deviation distance and Difference in nostril size between cleft and noncleft side.

  • PDF

A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data (발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구)

  • Park, Hae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Thickness Dependence of Size and Arrangement in Anodic TiO2 Nanotubes

  • Kim, Sun-Mi;Lee, Byung-Gun;Choi, Jin-Sub
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3730-3734
    • /
    • 2011
  • The degree of self-assembly and the size variation of nanotubular structures in anodic titanium oxide prepared by the anodization of titanium in ethylene glycol containing 0.25 wt % $NH_4F$ at 40 V were investigated as a function of anodization time. We found that the degree of self-assembly and the size of the nanotubes were strongly dependent on thickness deviation and thus indirectly on anodization time, as the thickness deviation was caused by the dissolution of the topmost tubular structures at local areas during long anodization. A large deviation in thickness led to a large deviation in the size and number of nanotubes per unit area. The dissolution primarily occurred at the bottoms of the nanotubes ($D_{bottom}$) in the initial stage of anodization (up to 6 h), which led to the growth of nanotubes. Dissolution at the tops ($D_{top}$) was accompanied by $D_{bottom}$ after the formed structures contacted the electrolyte after 12 h, generating the thickness deviation. After extremely long anodization (here, 70 h), $D_{top}$ was the dominant mode due to increase in pH, meaning that there was insufficient driving force to overcome the size distribution of nanotubes at the bottom. Thus, the nanotube array became disorder in this regime.

Developing of Grading Method using 3D Body Measurement Data of Women in Their Thirties -Focusing on Their Proper Body Types-

  • Shin, Ju-young Annie;Nam, Yun-ja
    • Fashion & Textile Research Journal
    • /
    • v.19 no.6
    • /
    • pp.749-758
    • /
    • 2017
  • The purpose of the present study is to develop a grading deviation, which is appropriate for the body type of women in thirties, by analyzing the three-dimensional body type. The materials for the study were adopted from the body measurement data of women in the age group of 30 to 39 years old, provided from Size Korea. By reflecting the factor analysis results using the three-dimensional shape measurement, deviations were derived. First, six factors influencing the changes in human body shape were derived as waist-hip length factor, bust-waist shape factor, back protrusion back shoulder factor, bust length factor, shoulder length factor, and frontal waist dart factor. The bust size and height, which can be easily utilized for the top original grading, were used for deriving a regression formula, and the deviation was set in accordance with the result. Second, by applying the deviation which reflects the changes in the body shape, the crimps which were generated due to the application of existing deviation were remarkably reduced, indicating that the grading of the present study is more fitting than the existing one. The deviation derived by the analysis of actual increase and decrease of body size was more fitting than the existing one. This was proved by actual wearing experiment, which represents the significance of this study.

Influences of Reeling Conditions on the Denier Control of Raw Silk for Automatic Silk Reeling with Fixed Size (정섬도자동조사에 있어서 경사조건이 생사섬도관리에 미치는 영향)

  • 이인전
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.2
    • /
    • pp.147-155
    • /
    • 1974
  • The purpose of this study is to find out influence of reeling conditions on the denier control of raw silk for automatic silk reeling machine. The results obtained are as follows: 1. Effect of groping end part temperature (X$_1$) (1) Average size Y=0.02945X$_1$+18.27 (2) Size range Y=0.04224X$_1$+2.99 (3) Size deviation Y=0.01667X$_1$-0.13 (4) Maximum deviation of size Y=0.04657X$_1$-0.929 (5) Quality of raw silk Y=-0.07055X$_1$+10.082. Effect of silk reeling bath temperature (X$_2$) (1) Average size Y=0.0334X$_2$+19.08 (2) Size range Y=0.016X$_2$+5.24 (3) Size deviation Y=0.0014X$_2$+1.05 (4) Maximum deviation of size Y=0.0206X$_2$+1.59 3. Effect of silk reeling velocity(X$_3$) (1) Size range Y=0.01797X$_3$+3.95 (2) Size deviation Y=0.00327X$_3$+0.845 (3) Maximum deviation of size Y=0.00905X$_3$+1.50 (4) Quality of raw silk Y=-0.03232X$_3$+8.62

  • PDF

Selection of Grading Deviations to Develop Improved Baseball Leg Guards for Size Suitability and Efficiency (사이즈 적합성과 효율성이 향상된 야구 다리보호대 개발을 위한 그레이딩 편차 선정)

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.184-195
    • /
    • 2017
  • Baseball is a life sport that gives vitality to people. However, currently available leg guards do not have a variety of sizes and it is very difficult to purchase a leg guard that is suitable for the size of a specific consumer. Therefore, this study investigated the size system of a leg guard sold in the market and suggested a grading deviation suitable for the legs of Korean males. The results of the study were as follows. First, most brands were sold only in three size systems as children's, teenagers, and adults. Adult size systems were not subdivided. Second, Korean male legs were classified into Group 1 (large girth and height and lower body muscle) and Group 2 (small girth and height and low underbody muscle). Third, the size system is based on vertical items such as height and mid-thigh circumference. Each group produced 10 sizes. The smallest height or the largest height was also found to be about 4.5 to 5.0cm smaller or larger than the sample size for each group. The total length of the leg guard was about 2.5cm when the height was increased or decreased by one size. It was confirmed that the deviation of the circumference of the mid-thigh should be about 2.0cm larger or smaller than the sample size even if the height is the same. The deviation of the knee circumference and ankle circumference was smaller than the other circumference. In conclusion, the dimension combinations of the leg guard must be set differently to provide a leg guard with high size suitability according to leg type.

The Raw silk Size-Deviation Relationship with the Cocoon cultured in Korea (한국산 가잠계 견사섬도가 생사섬도 편차에 미치는 영향)

  • 최병희;김동욱
    • Journal of Sericultural and Entomological Science
    • /
    • v.3
    • /
    • pp.61-67
    • /
    • 1963
  • This report is prepared to find how the filament of cocoon bave size deviation relates with the raw silk made by them which are intensively cultured in this country. Three recommended hybrid varieties and two varieties under working at Suwon Sericultural Experiment Station were selected as specimens. The cocoons were reeled as an individual filament of every fifty meters long skein with a wrap reel to weigh the denier and to investigate the relationship of the above statement so that it may be used for the quality estimation before processing it into raw silk. The conclusions obtained are as follows. (1) The variation of Pk${\times}$Sn was found as best cocoon for 21 denier raw silk use, but the number of cocoon to make the denier has to be eight which might cause more labor cost. (2) Baektoo-Kumkang and Myohiang-Chongchon were found as economical varieties for 21 denier use. (3) Seulak-Soyang is a proper variety for the use of 14 or 28 denier silk use. (4) Myohiang-Chongchon did not confirm a good property from the aspect of denier deviation. (5) It was found that there was a fairly strong corelationship between the mean cocoon bave size deviation as indicated by Ono's report. (6) Three graphs were prepared to estimate the cocoon quality before processing into various sizes of raw silk using the mean cocoon bave size and the raw silk size to be prepared. (7) Mean time, the graph which is able to estimate the expectable grade of the raw silk size deviation was designed for the practical use. (8) The expectable grade of the varieties used in this report were found as following data. Notice (A......cocoon number to make raw silk (B......total cocoon bave size deviation (C......expectable silk grade (9) The result of the work concerning the expectable denier deviation on 21 denier silk was the same with the statistical actual testing result as 1.25 D while the distribution showed farther necessity of improvement in technically.

  • PDF

Studies of Raw Silk Size Nonuniformity. (생사비균일섬도발생 원인에 관한 연구)

  • 최병희
    • Journal of Sericultural and Entomological Science
    • /
    • v.7
    • /
    • pp.65-74
    • /
    • 1967
  • This work has been carried out to find the fundamental reasons of raw silk size nonuniformity by studying with the physical nature and its bave formation through the worm spinnerate with anatomical device. Mean time, the uniformity improving method is also attached to this paper after throughfall theoretical study. 1. According to the anatomical study of the silkworm spinnerate, the physical form decides the fiber cross section and also spinns more finner size as the spinning is continued collaborating with the muscle pressure and decrease of liquid silk in the silk gland. 2. The bave size deviation of the Korean cocoons have shown a little difference among the varieties, but, they are conclued as 0.58 denier in average which caused some size deviation of the raw silk inevitably. 3. The raw silk nonuniformity increases when the cocoon have size is not suitable with the proposed raw silk size. 4. The nonuniformity is also increased very much during the filature process in case of poor technical work, but even if we do our best, the best result is found as 30 percent improvement which is still worser than the natural cocoon size deviation. 5. It is required to be careful for the selection of silkworm variety in order to improve the nonuniformity of raw silk so that the bave size be suitable for the proposed silk. 6. The definite size silk reeling method could made better uniform silk, 20 percent at least, than the definite cocoon number silk reeling method. 7. A newly developed denier(21d) gauge was applied for the multiends type silk reeling machine which is widely used in Korea, and the result of the method showed 1.30 denier size deviation, but, in case of no use of it was 1.57 denier size deviation, that is, it could improve two grades more than the normal reeling method.

  • PDF

Effect of liquid viscosity on the degree of uniformity of drops from swirl spray nozzles (와류 분무 노즐에 의해 형성되는 액적들의 균일도에 액체의 점도가 미치는 영향)

  • 이상용;김인구;조한권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.538-546
    • /
    • 1989
  • Effect of liquid viscosity was studied experimentally on the drop size distributions of the liquid sprays from swirl atomizers. Glycerine-Water mixtures were used as test fluids for the experiments. Drop sizes of the liquid sprays were measured with the light scattering method. The concept of the standard deviation was introduced to represent the degree of uniformity of the drop size distributions. Experimental results show that the spray drops become coarser and less uniform with the liquid of higher viscosity. The effect of viscosity on the Sauter mean diameter and the standard deviation appeared to be more significant with the lower injection pressure. It was also confirmed that the Sauter mean diameter increases with the increase of the liquid viscosity and with the decrease of the injection pressure.