• Title/Summary/Keyword: Size Measurement

Search Result 3,401, Processing Time 0.033 seconds

A Study on the Problems of Domestic Women Size in the Ready-Made Clothing (성인여자 기성복의 치수실태에 관한 조사연구)

  • 공민희
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.1
    • /
    • pp.23-36
    • /
    • 1982
  • The purpose of this study was to investigate the problems of consumer and producer in women's ready-made clothing through questionaires, and to solve the problems presented by questionaires. The point at problems of ready-made clothing indicated by the consumer and producer altogether focused on the size. Therefore this study on the size of ready-made clothing was carried out. The size selected for the research materials were producer's size, domestic researchers' measurement size, KS size in the '81, and foreign standard sizes. The results of this study were as follows: 1) As comparing three kinds of size the producers' size(A), domestic researchers' measurement size(B), and KS size(C) it follows that: ① To the same circumference of bust, the waist measurement showed in following order: B>C>A, and the hip measurement showed generally in following order: A>B. ② The extent of bust measurement showed in following order: B>C>A. ③ The sort numbers of size showed in following order: C>B>A. 2) As Comparing with foreign standard sizes, the sort numbers of our standard size were much less than foreigns as following order: DOB(102)>JIS(78)>BS(39)>PS(29)>KS(15)FNOR(10). 3) The reasonable size was made by referring to the producer's size, researchers' measurement size, and KS size.

  • PDF

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Proposal of Nail Tip Size by Measuring Nail Size of Korean Women in Their 20s -Focusing on Size Comparison Through Direct Measurement and 3D Scanner Measurement- (20대 국내여성의 손톱 사이즈 측정을 통한 네일 팁 사이즈 제안 -직접측정법과 3D 스캐너측정법을 통한 사이즈 비교를 중심으로-)

  • Lee, Eunsil;Kim, Eunsil
    • Journal of Fashion Business
    • /
    • v.24 no.1
    • /
    • pp.102-116
    • /
    • 2020
  • After its introduction in Korea, nail art is becoming active, especially among women in their 20s and 30s who are interested in fashion and beauty. Although self-nail tips are available online in various designs for each brand that is currently on the market, these designs and sizes of self-nail tips on the market are different for each age group. Since the design or size is not suggested for the different situations, there are difficulties in purchasing products that match the shape and size of nails of consumers. In this study, frequency analysis was performed using 'SPSS statistics 21.0 for windows program' to analyze data obtained by direct measurement method and 3D scanner measurement method for Korean women in their 20s. For comparative analysis between direct and 3D scanner measurements, a corresponding sample, 'T-test', was performed. As a result, we proposed the standardization of nail tip size after comparative analysis between direct measurement and 3D scanner measurement. Previous studies have been proceeding with direct measurement method. However, this study introduced a 3D scanner measurement method in the nail field and attempted the standardization of nail size by age group of Korean women. Importantly, this sutdy suggests standardization of nail tip size among missing body sizes.

The Suitability of the Size Classification of Dress Shirts on the Market (시판 드레스셔츠의 치수 구분 적합성)

  • Han, Eun Joo;Kweon, Soo Ae;Choi, Jong Myoung;Song, Jae Min;Lim, Bo Youn
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.5
    • /
    • pp.695-702
    • /
    • 2015
  • This study provides basic data that are helpful to prepare a sizing system for dress shirts that improves the wearer's size fitness. The 16 different parts of the dress shirts were measured for 24 pieces of dress shirts with three kinds of size (95, 100 and 105) among the eight different brands on the market. The measurement sizes of the dress shirts analyzed the accuracy of the size information, size classification by size designation, and differences of size by brand. The results of the study were: 1. The size information of dress shirts differed from customer demand. 2. The size increments between size designations differed from each other even though measurement sizes of the dress shirts increased as the size designation increase. 3. Measurement sizes of the dress shirts were different between brands even for dress shirts of the same size designation. It is necessary that manufacturers secure an accurate and standardized sizing system and provide accurate information for the measurement sizes of dress shirts on an online shopping mall.

An Analysis of Size System and Patterns of Ready to Wear Basic Skirts for Middle Age Women (중년여성 브랜드를 통한 기본 스커트의 치수실태 및 패턴분석)

  • Lee, Jung-Soon;Goo, Mi-Ran
    • Fashion & Textile Research Journal
    • /
    • v.6 no.6
    • /
    • pp.756-764
    • /
    • 2004
  • The purpose of this study is to analyze of size and patterns of ready to wear basic for middle age women. For this purpose, I select 9 brands and analyze the basic skirts size system marketed in 2002 spring in Korea. To study the actual size system, I have compared size labeling, which I researched, with Korean Industrial Standard Size Chart. And I also have compared body measurement with the product size. To study the pattern, I have classified the composition of the skirt into 24 items. The different result shows between this study and Korean Industrial Standard Size Chart. The waist circumference is smaller than it should be, and the hip circumference is larger than it should be. As I have examined the body measurement and the product size, variability of the waist circumference depends on the location of the waistline. For the hip circumference, I have found that both the body measurement and the product size are same, or the product size is smaller than the body measurement. Both cases have been found to be over 67%. I have classified the analysis of the pattern into four components; circumference, relevance to waist line, dart, and length. For the waist circumference, the same size of the front and the back is 44.4%, and making the front larger is 44.4% also. In the hip circumference, the identical size of the front and the back is 66.7% and the larger size of back is 22.2%. Regarding darts placement, it is moved to the side lines from the middle of 1/2 of waist lines, dart intake was 1.3~3.2 cm, the length of darts is 7.2~12.7 cm.

Size Measurement of Radioactive Aerosol Particles in Intense Radiation Fields Using Wire Screens and Imaging Plates

  • Oki, Yuichi;Tanaka, Toru;Takamiya, Koichi;Osada, Naoyuki;Nitta, Shinnosuke;Ishi, Yoshihiro;Uesugi, Tomonori;Kuriyama, Yasutoshi;Sakamoto, Masaaki;Ohtsuki, Tsutomu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Background: Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. Materials and Methods: A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of $^{11}C$-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. Results and Discussion: The size distribution for $^{11}C$-bearing aerosol particles was found to be ca. $70{\mu}m$ in geometric mean diameter. The size was similar to that for $^7Be$-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. Conclusion: The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

O-ring Size Measurement Based on a Small Machine Vision Inspection Equipment (소형 머신 비전 검사 장비에 기반한 O링 치수 측정)

  • Jung, YouSoo;Park, Kil-Houm
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.41-52
    • /
    • 2014
  • In this paper, O-ring size measurement algorithm based on a small machine vision inspection equipment which can replace a expensive and large machine vision inspection equipment is presented. The small machine vision inspection equipment acquires a image from a CCD camera shooting a measurement plane which located on a back light and the proposed size measurement algorithm is apply to the image. For improvement of size measurement accuracy, camera lens distortion correction and perspective distortion correction are conducted by software technique. Consider O-ring's shape, ellipse fitting model is applied. In order to increase the reliability of ellipse fitting, RANSAC algorithm is applied.

A Study on the Measurement of Korean Women′s Head for Headgear Pattern Making (모자제작을 위한 여자 머리 계측에 관한 연구)

  • 안영실;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.5
    • /
    • pp.743-756
    • /
    • 2004
  • The purpose of this study is to set measurement parts which are important to identify the size and shape of the head in order to produce tightly fitted hats, and to identify detailed sizes and the major factors of head shape classifications of Korean women. A total of 285 Korean women's in the age group of 18 to 35 years old. It were measured through the direct measurement method by selecting 67 measurement items. Materials were analyzed by SPSS Ver.10 and technology statistics and factor analysis were performed according to the agenda. An attempt was made to conduct factor analysis of the measured region of the head in women's. Here, this study drew the head and the facial parts horizontal size as Factor 1, the head and facial parts vertical size as Factor 2, the circumference and width item as Factor 3, the factor representing the form of head height as Factor 4, the factor expressing the proportion of the facial form as Factor 5 and the factor about the frontal and back head form on the plan of the middle as Factor 6. Through this study, we will be able to systemize head measurement materials that can differentiate Korean's head from other peoples' and can use the results in developing head shape models according to Korean's head shape by selecting major head parts needed to identify the sizes and shapes.

  • PDF

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography (초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

A Study on Target Ages and Sizes of Korean Women′s Ready-made Clothes (한국 성인여자 기성복 브랜드의 타깃 연령 및 생산사이즈에 관한 실태조사 연구)

  • 조영아
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.549-561
    • /
    • 2000
  • The purpose of this study was to survey and analyze the age classification of women customers as a target market and sizes on a label that were actually produced by each brand in Korean national brands ; they were classified into size for bodice and bottom, and compared with the distribution of national data of women's body measurement. They were analyzed and classified by brand groups of 'miss', 'missy', 'Mrs.'and 'madam', The results were ; 1) It was found that recent products for ready-made for women's clothes tend to be designed with target to the measured ages classified by the range of five or ten years. The main practice was that for 'miss'brand group the age range was of five years, and for 'missy'brand group, ten years. And for 'Mrs'and 'madam'brand groups, it was of 15 or 20 years. So that, it is necessary to design their clothes based on their features of body considering the intervals of age. 2) 'Mrs'and 'madam'groups were most remarkable for their distribution into a vast range of sizes for three control dimensions and waist girth size when compared to 'miss'and 'missy'groups. The distribution of brand size had no relation with that of body measurement, and in particular, none was produced for short height size between 145 and 150 ㎝. For tall height size between 175 and 180 ㎝, many brand sizes were distributed while body measurement was few. It means that distribution of brand size was different from real distribution of body measurement was few. It means that distribution of brand size was different from real distribution of body measurement as a result that the larger the bust girth in such cases over 160 ㎝, the larger the size of hip girth. Even as for the height 155 and 160 ㎝ in which body measurement is concentrated, there were many problems because while sizes of 'large'bust girth and 'small'hip girth had a large distribution, their clothes were not produced.

  • PDF