• Title/Summary/Keyword: Size Inspection

Search Result 643, Processing Time 0.028 seconds

Effective Motor Evoked Potential Waveforms in Patients with Lower Extremity Weakness (다리에 힘이 없는 환자에서 효과적인 운동 유발전위 파형 측정에 대한 고찰)

  • Lim, Sung-Hyuk;Park, Sang-Ku;Han, Hung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.1
    • /
    • pp.41-48
    • /
    • 2016
  • Motor evoked potential of spinal surgery is known to cause damage due to the movement path of the continuous scan operation and surgery can be performed with minimized disability after surgery. However, if it is not at all formed at the wave motion evoked potential can occur during surgery and, in some cases the size of the waveform to be measured is very small and intermittent. In this case, the surgery cannot provide information about whether there is neurological damage. Increased intensity of the wave-induced motion of the dislocation does not occur if it appears in a very small amplitude stimulus, but changing the inspection area that electrical stimulation of the waveform changes could not be found. However, stimulation of a wide area in the cerebral cortex was found to occur with a waveform in the patients who underwent examination. Through this study, we propose a useful motor evoked potential test. From November to December 2015 three spine surgery patients visited Samsung Medical Center as neurosurgery patients with omission discomfort, gait disturbance, and no symptom of strength before surgery. In spine surgery patients with motor grade weakness, when motor evoked potential waveform has not been measured, in examination of the site of electrical stimulation of the cerebral cortex from entering the C3+C5/C4+C6 or C3+C1/C4+C2 if by the activity of more motor neuron unit, it was found that the waveform is better formed.

Defect Detection of Impacted Composite Tubes by Lock-in Photo-Infrared Thermography Technique (위상잠금 열화상기법을 이용한 복합재 튜브 충격 손상 결함 측정)

  • Kim, Kyoung-Suk;Jeon, So-Young;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.139-143
    • /
    • 2011
  • The problem of delamination of composite tubes by impact has been acknowledged in aerospace and automobile industry. Non-destructive testing(NDT) methods in composite material structure are important to evaluate reliability of composite structure. There are many kinds of NDT methods which can detect the inside defect of the composite material such as Infrared Thermography(IRT). Infrared thermal imaging of object is different from that of a defect, in heated composite tubes with an internal defect, and then location and size of a defect can be measured by the analysis of thermal imaging pattern. In this study, Lock-in Infrared thermography detect internal defects of Impacted composite tubes by the inspection of infrared lay radiated from the surface of composite tubes.

Quantitative Defects Detection in Wind Turbine Blade Using Optical Infrared Thermography (광 적외선열화상을 이용한 풍력 블레이드의 결함 크기 정량화 연구)

  • Kwon, Koo-Ahn;Choi, Man-Yong;Park, Hee-Sang;Park, Jeong-Hak;Huh, Yong-Hak;Choi, Won Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.25-30
    • /
    • 2015
  • A wind turbine blade is an important component in wind-power generation, and is generally exposed to harsh environmental conditions. Ultrasonic inspection is mainly used to inspect such blades, but it has been difficult to quantify defect sizes in complicated composite structures. Recently, active infrared thermography has been widely studied for inspecting composite structures, in which thermal energy is applied to an object, and an infrared camera detects the energy emitted from it. In this paper, a calibration method for active optical lock-in thermography is proposed to quantify the size. Inclusion, debonding and wrinkle defects, created in a wind blade for 100 kW wind power generation, were all successfully detected using this method. In particular, a ${\phi}50.0mm$ debonding defect was sized with 98.0% accuracy.

Comparison of the Electronic Methods of Raw Silk Testing and Grading with Those of the Current Methods I. Defference in Inspection Results and Grading to the Electronic Methods (생사검사에 있어서 현행방법과 전자식 방법에 대한 비교분석 I. 전자식 검사방법에 의한 검사성적과 등급비교)

  • 최병희;김한수
    • Journal of Sericultural and Entomological Science
    • /
    • v.34 no.1
    • /
    • pp.57-71
    • /
    • 1992
  • These studies were carried out to establish Korean opinion about "The electronic method of raw silk testing and grading" which was taken shape along with the report by Silk Standard Committee(S.S.C.) at the meeting of International Silk Association(I.S.A) Directing Board session held in Zurich Swiss. This establishment was througly examine whether or not the above are the essential factors to be fulfilled in force as a international standard method of raw silk testing and grading.d grading.

  • PDF

A Synthetic Exponentially Weighted Moving-average Chart for High-yield Processes

  • Kusukawa, Etsuko;Kotani, Takayuki;Ohta, Hiroshi
    • Industrial Engineering and Management Systems
    • /
    • v.7 no.2
    • /
    • pp.101-112
    • /
    • 2008
  • As charts to monitor the process fraction defectives, P, in the high-yield processes, Mishima et al. (2002) discussed a synthetic chart, the Synthetic CS chart, which integrates the CS (Confirmation Sample)$_{CCC(\text{Cumulative Count of Conforming})-r}$ chart and the CCC-r chart. The Synthetic CS chart is designed to monitor quality characteristics in real-time. Recently, Kotani et al. (2005) presented the EWMA (Exponentially Weighted Moving-Average)$_{CCC-r}$ chart, which considers combining the quality characteristics monitored in the past with one monitored in real-time. In this paper, we present an alternative chart that is more superior to the $EWMA_{CCC-r}$ chart. It is an integration of the $EWMA_{CCC-r}$ chart and the CCC-r chart. In using the proposed chart, the quality characteristic is initially judged as either the in-control state or the out-of-control state, using the lower and upper control limits of the $EWMA_{CCC-r}$ chart. If the process is not judged as the in-control state by the $EWMA_{CCC-r}$ chart, the process is successively judged, using the $EWMA_{CCC-r}$ chart. We compare the ANOS (Average Number of Observations to Signal) of the proposed chart with those of the $EWMA_{CCC-r}$ chart and the Synthetic CS chart. From the numerical experiments, with the small size of inspection items, the proposed chart is the most sensitive to detect especially the small shifts in P among other charts.

Studies on the advanced model for quality control system of oriental medicine (한약재 품질관리체계 선진화 모형에 관한 연구)

  • Choi Sun-Mi;Yoon Yoo-Sik;Choi Hwan-Soo;Lee Mi-Young;Shin Soon-Shik;Lee Key-Nam;Chung Hee-Jin;Kim Hee-Soo;Sung Hyun-Jea
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.193-204
    • /
    • 2000
  • In this study, advanced model for quality control of oriental medicine and methods for practice was suggested through literature inspection, analysis of foreign system such as China and Japan, survey analysis on the current system, quality analysis of randomly selected oriental medicine samples, and intensive discussions among oriental medicine specialists 1. The quality of oriental medicine should be consistently controlled by Ministry of Health and Welfare form its cultivation or import to its circulation process to final consumer 2. All oriental medicines should be circulated as standardized goods which should be marked by lot numbers. The packing material and Packing size should be liberalized. The qualify should be differentialized though free competition among makers. 3. Realistic standards for pesticide, heavy metal and decolorant should be established though long-term monitoring process according to each oriental medicine's origin, therapeutic part, cultivation area, harvesting time, and cultivation method. 4. Ministry of Health and Welfare should educate oriental medicine's quality control personnel regularly or on demand, and establish specialist pool. Ministry of Health and Welfare should also establish oriental medicine information system to provide informations about quality of domestic or foreign oriental medicinal raw materials. 5. The government should provide information about foreign of oriental medicine market to importers. Quality of imported oriental medicine should be inspected before its customs clearance, and all imported oriental medicine should be circulated by standardized oriental medicine makers. 6. Oriental medicine's pharmacopoeia should be Published to provide quality standard of oriental medicine and improve it.

  • PDF

Investigation and Analysis of Forest Geospatial Information Using Drone (드론을 활용한 산림공간정보 조사 및 분석)

  • Park, Joon-Kyu;Jung, Kap-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.602-607
    • /
    • 2018
  • The destruction of forests requires continuous management due to the risk of disasters such as landslides and landslides. However, existing forest inspection methods are inefficient as they require a lot of manpower and time. Recently, drones are attracting attention as an effective way to construct and utilize spatial information. The size of the drone-related industrial market is rapidly increasing. In this study, we attempted to increase the efficiency of forest investigation utilizing drones. The study area was photographed through the use of drones, and ortho image and DSM were generated through data processing. Study results found that it was possible to calculate the area and the volume for the forest damaged area effectively by employing drones, and suggested the applicability of drones. In the future, it is expected that the method of analyzing the forested area using drones can save manpower and time compared to existing methods.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

A Novel Third-Order Cascaded Sigma-Delta Modulator using Switched-Capacitor (스위치형 커패시터를 이용한 새로운 형태의 3차 직렬 접속형 시그마-델타 변조기)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.197-204
    • /
    • 2010
  • This paper proposes a new body-effect compensated switch configuration for low voltage and low distortion switched-capacitor (SC) applications. The proposed circuit allows rail-to-rail switching operation for low voltage SC circuits and has better total harmonic distortion than the conventional bootstrapped circuit by 19 dB. A 2-1 cascaded sigma-delta modulator is provided for performing the high-resolution analog-to-digital conversion on audio codec in a communication transceiver. An experimental prototype for a single-stage folded-cascode operational amplifier (opamp) and a 2-1 cascaded sigma-delta modulator has been implemented m a 0.25 micron double-poly, triple-metal standard CMOS process with 2.7 V of supply voltage. The 1% settling time of the opamp is measured to be 560 ns with load capacitance of 16 pF. The experimental testing of the sigma-delta modulator with bit-stream inspection and analog spectrum analyzing plot is performed. The die size is $1.9{\times}1.5\;mm$.

Application and Design of Eddy Current based on FEM for NDE Inspection of Surface Cracks with Micro Class in Vehicular Parts (자동차부품의 마이크로급 표면크랙 탐상을 위한 FEM 를 기반한 와전류 센서 디자인 및 적용)

  • Im, Kwang-Hee;Lee, Seul-Ki;Kim, Hak-Joon;Song, Sing-Jin;Woo, Yong-Deuk;Na, Sung-Woo;Hwang, Woo-Chae;Lee, Hyung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.529-536
    • /
    • 2015
  • A defect could be generated in bolts for a use of oil filters for the manufacturing process and then may affect to the safety and quality in bolts. Also, fine defects may be imbedded in oil filter system. So it is very important that such defects be investigated and screened during the multiple manufacturing processes. Therefore, in order effectively to evaluate the fine defects, the FEM simulations were performed to make characterization in the crack detection of the bolts and the parameters such as number of turns of the coil, the coil size, applied frequency were calculated based on the simulation results. Simulations were carried out for the defect signal of eddy current probe. Exciter and receiver were utilized. In this paper, the FEM simulations were performed in both bobbin-type and pancake-type probe, both probes were optimized under Eddy current FEM simulations and the results of calculation were discussed.