• Title/Summary/Keyword: Size Inspection

Search Result 644, Processing Time 0.02 seconds

A Study on the Characteristics of Bridge Bearings Behavior by Finite Element Analysis and Model Test (유한요소 해석과 모형실험을 통한 교량받침의 거동특성 연구)

  • Lee, Jae-Uk;Jung, Hie-Young;Oh, Ju;Park, Jin-Young;Kim, See-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.96-106
    • /
    • 2014
  • The increased vibration level of the railway bridge could make significant noise and, also, cause structural damages such as fatigue cracks. Related to these subjects, a spherical elastomeric bridge bearing, which is layered by hemispherical rubber and steel plates, was investigated in terms of its vibration performance. Several different shape factors could be considered by changing the curvature of hemispherical surface and size in rubber and steel plate thicknesses in the manufacturing stage. The performance of the spherical elastomeric bearing for the reduction in vibration was compared with that of the conventional bearing by performing vibration experiments on a scale-downed model. The rubber material characteristics and spherical shape are found to be important parameters in reducing the bridge vibration.

An Experimental Study on Seismic Performance Evaluation of Retrofitted Column of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재로 보강된 기둥의 내진성능평가 실험)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.21-30
    • /
    • 2013
  • As increasing number of large-size earthquake, the social interest of seismic retrofitting of RC structure is growing. Especially, the RC columns that are not reflected seismic design can not resist lateral loads by the earthquake. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. Thus, the emergency columns reinforcement method is needed. That have a fast construction time, do not cause damage to the column. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly, but in recent years, carbon fiber sheet taking advantage of FRP (Fiber Reinforced Polymer) is widely used. In this study, retrofitting effect of seismic performance of FRP seismic reinforcement, which is possible to emergency construction, was examined. Reinforced concrete specimens were constructed to experimental study. The seismic performence of specimes retrifitted with FRP seismic reinforcement were evaluated. As a result, the seismic performance of specimen reinforced with FRP seismic reinforcement has been improved.

Characteristics and Dynamic Modeling of MR Damper for Semi-active Vibration Control (준능동 진동 제어를 위한 MR 감쇠기의 동적 모델링을 통한 특성분석)

  • Heo, Gwang-Hee;Jeon, Seung-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.61-69
    • /
    • 2013
  • This research is aimed to evaluate characteristics and dynamic modeling of MR damper for semi-active vibration control. A MR damper of semi-active type was designed and made for the purpose of controlling the vibration of a real-size model structure. Usually a semi-active control system equipped with a MR damper requires a dynamic model which expresses numerical data about the damping capacity and dynamic characteristics generated by a MR damper. To fulfil the requirement, a Power model and a Bingham model were particularly employed among many dynamic models of MR damper. Those models being contrasted with other ones, a dynamic test was carried out on the developed MR damper. In the test, excitation frequencies were conditioned to be 0.15 Hz, 1.0 Hz, and 2.0 Hz, and three different currents were adopted for each frequency. From these test results, it was found that displacement affected control capacity of the MR damper. The test results led to the identification of model variables for each dynamic model, on the basis of which a force-speed relation curve and expected damping force were derived and contrasted to those of the developed MR damper. Therefore, it was proven that the MR damper designed and made in this research was effective as a semi-active controller, and also that displacement of 2mm at minimum was found to be secured for vibration control, through the test using various displacements.

Study on Stable Use of Stainless EAF Oxidizing Slag as Fine Aggregate of Concrete (스테인리스 전기로 산화슬래그의 콘크리트용 잔골재 활용방안 검토)

  • Cho, Bong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.133-142
    • /
    • 2014
  • Recently, more focus is shift to imbalances in aggregate market supply and demand and an exhaustion of natural resources. In this situation, Electric arc furnace oxidizing slag (EAF Slag) has high application possibility as aggregate for concrete due to similar property with general aggregate. In this study, We've got the plan to assure the chemical stability of EAF Slag, and then experimentally tested the mechanical performance and durability for the fine aggregate used EAF Slag. On this test result, we suggest the application plan. At the result of this study, it shows that EAF slag would reduce the surface defect such as pop-out due to natural aging for the fixed hour and adjustment the grain size of EAF Slag. And mechanical performance and durability according to the replacement rate of concrete service, were revealed more than equal or equal compare to general aggregate. Hereafter, quality control must precede not to impede the beauty of concrete surface as assure the safety for aging and processing. And, to establish the environmental resource recycling system for by-products of steel, it should be made development of various application and guideline of quality control for the EAF slag aggregate. Moreover, it must be constantly studied all kind of engineering performance and durability for related to this study.

Tensile Behavior of Highly Ductile Cementitious Composites Using Normal Sand as Fine Aggregate (일반모래를 잔골재로 사용한 고연성 시멘트 복합체의 인장거동)

  • Lee, Bang Yeon;Kang, Su-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.178-184
    • /
    • 2017
  • This study was aimed to investigate the tensile behaviors of PE(Polyethylene) fiber-reinforced highly ductile cementitious composites with different combinations of micro silica sand and normal sand(river sand) with maximum particle size of 4.75 mm. Flow test result indicated the increase of flowability with higher replacement ratio of river sand. There was no noticeable difference in the mean compressive strength with different replacement ratio of river sand, but the variation in the compressive strength increased as higher amount of river sand was adopted for the replacement. The difference in the uniaxial tensile strength was negligible, but the tensile strain capacity was significantly influenced by the replacement ratio of river sand. It is thought that increased density of multiple cracks induced improved tensile strain capacity when higher percentage of river sand was adopted for fine aggregate. The deviation in the strain capacity increased as the replacement ratio of river sand was higher, as in the compressive strength. This study presented the feasibility of using normal sand instead of micro silica sand for highly ductile cementitious composites with equivalent or better uniaxial tensile performance, even though it might increase the deviation in the performance.

Code Change for using the High-Strength(550 MPa) Headed Deformed Bars of Large-Sized Diameter(57 mm) in Concrete Containments (대구경(57 mm) 및 고강도(550 MPa) 확대머리 철근의 콘크리트 격납구조물 적용을 위한 코드개정에 관한 연구)

  • Lee, Byung-Soo;Lim, Sang-Jun;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.147-161
    • /
    • 2017
  • Generally, significant amount of reinforcements are used in nuclear power plant structures and it may cause several potential problems during the construction. In particular, it is more difficult to pour concrete into structural member joint area than other areas because of the significant congestion of the joint area due to a lot of hooked bars, embedded materials, and other reinforcements. The purpose of this study is to solve these problems due to the reinforcement congestion by using the high-strength(ASTM A615 Gr.80) headed deformed bars of large-sized diameter(43 mm & 57 mm) in nuclear power plant structures as a alternative of standard hooked bars. In order to use headed deformed bars effectively, It is necessary to find the method how to relax limits on their use while maintaining or improving the anchorage capacity. Therefore, this study will analyze the results of tests planned to evaluate the influence of the restricted variables, such as bar size, yield strength, clear cover thickness.

Estimation on Filling Performance of Thixotropic Grout for Increasing Front-Water Depth of Gravity-Type Quay Wall (중력식 안벽 구조물의 증심 시공을 위한 가소성 그라우트의 충진성능 평가)

  • Jang, Kyong-Pil;Ryu, Yong-Sun;Kwon, Seung-Hee;Han, Woon-Woo;Oh, Myong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.169-177
    • /
    • 2017
  • Recently, as the size of transportation vessels has increased, there is a growing need for securing the front-water depths of existing port facilities. The method of deepening front-water depth is securing the depth of the port facility, and it is reinforced by grouting after excavating the rubble-mound to the required depth. The purpose of this study is to investigate the reinforcing performance and filling performance of thixotropic grout as a grouting material for reinforcing rubble-mound. Compressive strength tests were carried out for two types of thixotropic grout, and 5 specimens with a diameter of 400 mm and a height of 530 mm were manufactured and evaluated for filling performance. The required strength of reinforced rubble-mound required to ensure the safety of the structure is 6 MPa. All the thixotropic grouts used in this study were found to satisfy the required strength over 9 MPa at 7 days of age. As a result of visual observation of filling state of the filling performance test specimens, it was confirmed that the thixotropic grout was well filled up to the desired fillet height.

A Petrological Study of Stones Used in the Three Storied Stone Pagoda of Bulguksa Temple (불국사 삼층석탑에 사용된 석재의 암석학적 연구)

  • Park, Sung-Chul;Moon, Sung Woo;Kim, Sa-Duk;Jwa, Yong-Joo
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.11-24
    • /
    • 2015
  • In this study, the stone used for three storied pagoda of Bulguksa Temple, which is easy to access due to works for dismantle and restore will be analyzed on the basis of petrographic study, magnetic susceptibility, and ${\gamma}$-ray spectrometer, and identify petrographic characteristics. Also we will select candidate areas of fresh rock to change the stone used for three storied stone pagoda as from its provenance is presumed. According to the results of visual inspection, the stones used for the three storied stone pagoda are similar to the features of Namsan granite, which is distributed around Gyeongju-si, and when it comes to the section of the stupa finial, the features of all the parts from the stupa finial is similar to Namsan granite except for the section of Jeweled cover. On the other hand, the color, the composition, and the mineral size of the stones in the section from the part of jeweled cover are similar to Tohamsan granite. As a result of none-destruction inspection, it seems that the stones used for the three stories stone pagoda except for the section of jeweled cover are similar to the values for the magnetic susceptibility and the ${\gamma}$-ray spectrometer. On the other hand, Jeweled cover and the values of Tohamsan granite are alike. Namsan granite is appropriate in case that the stone used for three storied stone pagoda must be replaced to fresh rock because of damage by weathering. Meanwhile, Namsan granite is seperated from Yangsan fault. Due to this fact, Namsan granite appears to not only Mt. Namsan in Gyeongju, but also Dongcheon-dong, Gyeongju, and Huenggok-ri, Pohang. As a result, these two areas are suitable to the candidate area to change the stone used for three storied stone pagoda.

The Development of Real-time Feedback Vibration Control System Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 실시간 Feedback 진동제어 시스템 개발)

  • Heo, Gwang Hee;Kim, Chung Gil;Ahn, Ui Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.60-66
    • /
    • 2012
  • This paper aims to constitute a feedback vibration control system using wireless sensor networks and experiment it on a model structure to verify its effectiveness. For the purpose, we set up a feedback vibration control system composed of a wireless input/output(I/O) sensor node based on bluetooth, a home-made shear type MR damper, a shaker which generates a constant size of sine wave, and a simple beam model structure. The vibration control experiment was performed by shaking the 1/4 point of beam with a shaker. At the moment of shaking, we controled the vibration with MR damper which was placed vertically on the center of beam. Simultaneously, by acquiring acceleration response at the 2/4 point of beam, we evaluated the effectiveness of control capability. The control command was set to send a voltage signal to MR damper when the acceleration response, acquired from the wireless I/O sensor node placed at the center of beam, was more than a certain amount. Although the realtime feedback vibration control system constituted in this paper is effective only within a limited command system, it has been proven that the system was able to effectively decrease the vibration of structure by generating a control command aimed for realtime purpose. The system also showed a possibility to be used as a structural response control system adapting a variety of semi-active control algorithm.

Effect of Coating System to Prevent the Deterioration of Concrete Subjected to Compressive Stress (압축응력이 인가된 콘크리트의 열화제어를 위한 표면도막공법의 효과)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.23-30
    • /
    • 2012
  • For cracked concrete, it is obvious that cracks should be preferential channel for the penetration of aggressive substances such as chloride ions according to the previous researches. In order to extend the lifetime of cracked concrete, critical issues in the performance of the concrete is the risk of chloride-induced corrosion. Even though crack width can be reduced due to the high reinforcement ratio, the question is to which extend these cracks may jeopardize the durability of cracked concrete. If the size of crack is small, surface treatment system can be considered as one of the best options to extend the service life of concrete structures exposed to marine environment simply in terms of cost effectiveness versus durability performance. Thus, it should be decided to undertake an experimental study on the effect of surface coating system, which can be able to seal the concrete and the cracks to aggressive substances-induced corrosion in particular. In this study, it is excuted to examine the effect of surfaced treated systems on chloride penetration and carbonation through compressive stress induced cracks. Experimental results have showed conclusively that critical stress linked with deterioration, should be existed in compressive stress ratio 50 ~ 70% for chloride penetration and 70 ~ 80% for carbonation, respectively. When the critical stress is exceeded in concrete, a comparatively large deterioration was measured where the critical stress in concrete, the increase in the mass transportation is marginal in spite of the large increase in micro-cracks. As for the effect of surface coating system on crack-sealing, it can be seen conclusively that cracks can be healed.