• Title/Summary/Keyword: Size Chart

Search Result 222, Processing Time 0.025 seconds

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

Studies on the Engineering Characteristics of Alluvial Clayey Deposits in the Bay Area of Asan (II) (아산만지역 충적점토의 토질특성에 관한 연구(II))

  • 유능환;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.2
    • /
    • pp.55-66
    • /
    • 1988
  • This study was conducted to investigate the various engineering properties and correlationshops among the soil constants of alluvial clayey deposits distributed in the bay of Asan and their results are summarized as follows : 1. Grain size distribution of soil was consisted of 12 % of clay, 46-73 % of silt, 2-23 % of sand, and as for the consistency characteristics, 26-36 % of liquid limit, 18-21 % of plastic limit and 6-16 % of plastic index, and so the soil belonging to as a lower plastic nonorganic clay, it's specific gravity was 2,66-2.70, and the location on the plastic chart was approximately above the A-line. Z The natural moisture content and unit weight were 30-43 % and 1.76-1.87 g I cm$_3$, respectively, and according to increment of natural moisture content, the unit weight was decreased, and the initial void ratio and degree of saturation were shown of 0,87-1119 and 92- 100 %, most of saturated. 3. Cone resistance value which was shown 2.4 - 6.5 kg / $cm^2$ was a little lower and it was increased with the depth of layer and shown the formular $q_c=0.7_z+1.32$. 4. Unconfined compression strength was about 0.18-0.43kg /$cm^2$, cu, 0.1-0.22kg / $\psi$, $2-6^{\circ}$ under uu-test condition of triaxial, and CCU, 0.08-0.3 kg/cm , $\psi$, $12-18^{\circ}$ under the condition of cu-test. 5. Pre-consolidation load of characteristics of consolidation was 0.4-0.8 kg / $cm^2$, compression index, about 0.17-0.33. 6. Liquid limit and plastic index were incresased with the increment of clay content but most of alluvial clay was appeared as a normal through non-activity clay soil shown more natural moisture content than liquid limit, and their relationship as follows : LL=0.38( cy+54.8), PI=0.836(LL -17.8), PI =0.468(LL -0.48) 7. The initial void ratio presented correlationship of positive among clay content, natural moisture content and liquid limit, and that of reverse with unit weight, and their results as follws : $e_o=0.024(w_n+0.2)$, $e_o=e_o=0.0003c_y+0.0005 LL+0.0151 W_n+\frac{3.58}{r-t}-1.52$ 8. It was shown that the compression index has correlationship of postive among the clay content, liquid limit, plastic index, natural moisture content and initial void ratio, and their relationships as follows ; $c_c=0.44(e_o-0.47)$, $c_c=0.001$

  • PDF

Functional outcome predictors following mandibular reconstruction with osteocutaneous fibula free flaps: correlating early postoperative videofluoroscopic swallow studies with long-term clinical results

  • Gonzalez, Santiago R.;Hobbs, Bradley;Vural, Emre;Moreno, Mauricio A.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.30.1-30.8
    • /
    • 2019
  • Background: Advancements in the field of microvascular surgery and the widespread adoption of microvascular surgical techniques have made the use of osteocutaneous fibula free flaps the standard of care in the surgical management of segmental mandibular defects. Although the literature possesses abundant evidence to support the effectiveness of fibula free flaps as a reconstructive method, there are relatively few studies reporting on outcomes as objectively measured by videofluoroscopic swallowing studies (VFSS). The purpose of this study is to explore the potential correlation between early postoperative VFSS and the long-term swallowing outcomes in patients who underwent mandibular reconstruction with fibula free flaps. Methods: We performed a retrospective chart review of 36 patients who underwent mandibular reconstruction with osteocutaneous fibular free flaps between 2009 and 2012. Demographics, clinical variables, VFSS data, and diet information were retrieved. Penetration and aspiration findings on VFSS, long-term oral feeding ability, and the need for gastrostomy tube were statistical endpoints correlated with postoperative clinical outcomes. Results: Thirty-six patients were reviewed (15 females and 21 males) with a mean age of 54 years (7-81). Seventeen cases were treated for malignancy. The size of the bony defect ranged from 3 to 15 cm (mean = 9 cm). The cutaneous paddle, a surrogate for soft tissue defect, ranged from 10 to 125 ㎠ (mean = 52 ㎠). A gastrostomy tube was present in patients preoperatively (n = 8), and postoperatively (n = 14). Seventeen patients had neoadjuvant exposure to radiation. Postoperative VFSS showed penetration in 13 cases (36%) and aspiration in seven (19%). Overall, 29 patients (80.6%) achieved unrestricted diet, and this was statistically correlated with age (p = 0.037), radiation therapy (p = 0.002), and preoperative gastrostomy tube (p = 0.03). The presence of penetration or aspiration on VFSS was a strong predictor for long-term unrestricted oral diet (p < 0.001). Conclusion: Early postoperative VFSS is an excellent predictor for long-term swallowing outcomes in patients undergoing mandibular reconstruction with osteocutaneous fibula free flaps.

A Study on High-Power Handling Capability of X-Band Circular Waveguide Cavity Filter (X-대역 원통형 도파관 캐비티 필터의 고전력 핸들링 능력 연구)

  • Lee, Sun-Ik;Kim, Joong-Pyo;Lim, Won-Gyu;Kim, Sang-Goo;Lee, Pil-Yong;Jang, Jin-Baek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.49-60
    • /
    • 2017
  • In this paper, we presented the result of the study on high-power handling capability of the X-band circular waveguide cavity filter configured at the output of high power amplifier(120 W) for geostationary satellites. The dual mode circular waveguide cavity filter with 6th order is selected and the physical model of the filter is designed after determination of the size of resonator from mode chart. Multipactor margin analysis is performed by the SEM method and the VMF method. The result shows that the VMF method predicts lower multipactor breakdown thresholds than the SEM method. Evaluating the multipactor margin obtained by the VMF method to ECSS criteria, we could decide to perform multipactor test. The multipactor test conducted in ESA facility shows that multipactor did not occur even until the RF power increased up to 540 W. In consequence, by both analysis and test, we could verify that the X-band circular waveguide cavity filter has the sufficient high-power handling capability to operate on orbit.

Screening Colonoscopy from a Large Single Center of Thailand - Something Needs to be Changed?

  • Aswakul, Pitulak;Prachayakul, Varayu;Lohsiriwat, Varut;Bunyaarunnate, Thirapol;Kachintorn, Udom
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1361-1364
    • /
    • 2012
  • Background: Results of screening colonoscopy from Western countries reported adenoma detection rates (ADRs) of 30-40% while those from Asia had ADR as low as 10%. There have been limited data regarding screening colonoscopy in Thailand. The objectives of this study were therefore to determine polyp and adenoma detection rates in Thai people, to evaluate the incidence of colorectal cancer detected during screening colonoscopy and to determine the endoscopic findings of the polyps which might have some impact on endoscopists to perform polypectomy. Materials & Methods: This study was a retrospective electronic chart review of asymptomatic Thai adults who underwent screening colonoscopy in our endoscopic center from June 2007 to October 2010.Results: A total of 1,594 cases were reviewed. The patients had an average age of $58.3{\pm}10.5$ years (range 27-82) and 55.5% were female. Most of the cases (83.8%) were handled by staff who were endoscopists. A total of 488 patients (30.6%) were reported to have colonic polyps. Left-sided colon was the most common site (45.1%), followed by right-sided colon (36.5%) and the rectum (18%). Those polyps were removed in 97.5% of cases and 88.5 % of the polyps were sent for histopathology (data lost 11.5%). Two hundred and sixty three cases had adenomatous polyps, accounting for 16.5 % ADR. Advanced adenomas were detected in 43 cases (2.6%). Hyperplastic polyps were mainly located distal to the splenic flexure of the colon whereas adenomas were found throughout the large intestine. Ten cases (0.6%) were found to have colorectal cancer. Four advanced adenomas and two malignant polyps were reported in lesions ${\leq}$ 5 mm. Conclusion: The polyp detection rate, adenoma detection rate, advanced adenoma detection rate and colorectal cancer detection rate in the screening colonoscopy of Thai adults were 30.9%, 16.5%, 2.6% and 0.6% respectively. Malignant transformation was detected regardless of the size and location of the polyps. Therefore, new technology would play an important role indistinguishing polyps.

The Use of Greater Saphenous Vein In Situ Graft in Arterial Occlusive Disease of Lower Extremity (하지동맥 폐쇄성 질환에서 자가 대복재정맥 정위 이식편의 이용)

  • Shin Yong-Chul;Kim Mi-Jung;Song Chang-Min;Ahn Jae-Bum;Kim In-Sub;Kim Woo-Sik;Kim Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.456-461
    • /
    • 2006
  • Background: Distal anastomosis using artificial vascular graft is difficult when luminal size mismatch occurred owing to severe occlusion of popliteal artery and its branches. So we reconstructed blood flow to ischemic lower limb by using autologous greater saphenous vein in situ graft (GSVISG) as vascular graft material. Material and Method: From July 2000 to July 2005, 26 patients treated using GSVISG. We analyzed clinical results retrospectively by chart review. Result: There was no in hospital or early postoperative death and 6 late deaths occurred during follow up period. Postoperative complications were 5 cases of early graft obstruction, 2 cases of wound dehiscence, 1 case of graft aneurysmal change, 1 case of seroma formation at inguinal wound and 1 case of graft injury during valvulotomy. Overall patency rate during follow up period was 69.3%. Conclusion: Greater saphenous vein in situ graft is acceptable vascular graft for arterial occlusive disease of lower extremity.

Environment of Deposition and Characters of Surface Sediments in the Nearshore off Byun-San Peninsula, Korea (변산반도 연근해 표층 퇴적물의 특성과 퇴적환경)

  • Oh, Jae-Kyung;Choi, Kyu-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.2
    • /
    • pp.107-116
    • /
    • 1999
  • To study the characters of surface sediment and to describe the seasonal depositional environment as a result of sedimentation process off Byun-San Peninsula, a total 61 samples of surface sediment (32 samples in summer; 29 samples in winter) were collected and analysed. A digitized depth data from sea chart and echosounding profiles along five trans-sections were helpful for understanding the morphological factors. The types classified by the characters of surface sediment are type I (sand, S), type II (silty sand, zS), and type ill (sandy silt, sZ). Mean grain size varies from 2.11 to 7.81 ${\Phi}$. The positive-skewness shows the typical tide-dominated environment. The sediment type of the northwestern stations is medium sand and the sorting value is 0.5~1.4 ${\Phi}$ of well/moderately sorted. Meanwhile, other stations are composed of muddy sands and sandy muds transported from rivers and offshore. These sediment types toward inshore change gradually from silty sand to sandy silt. According to the C/M diagram, there are three major transport modes of sediment: bed load (Mode A), graded suspension (Mode B), and suspension (Mode C), correlating with north-eastern sandy area, middle part of silty-sand area, and southern sandy-silt area, respectively. The result of Principal Component Analysis shows also similar pattern of sediment types. In result, sediment texture of type III tends to be finer and more poorly-sorted than that of type II and sediment facies are correlateed with sedimentation process.

  • PDF

Clinical Characteristics of Subacute Necrotizing Lymphadenitis (아급성 괴사성 림프절염의 임상적 고찰)

  • Park Chan-Hum;Kim Hee-Dong;Park Jun-Young;Jo Hyeong-Ju;Jun Jin-Hyoung;Park Youn-Kyu;Rho Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.217-221
    • /
    • 1999
  • Background and Objectives: Subacute necrotizing lymphadenitis or Kikuchi's disease has now become recognized in many parts of the world as a well-defined clinicopathologic entity. It typically affects cervical lymph nodes of young women, and subsides spontaneously within a few months without recurrences. The purpose of this study is to report the clinicopathologic finding, radiologic finding and many laboratory tests to elaborate the criteria that are useful in distinguishing this entity from inflammatory disease, granulomatous disease, lymphoma, malignant disease. Material and Methods: Authors evaluated 22 patients, who were diagnosed as subacute necrotizing lymphadenitis on excisional biopsy or fine needle aspiration cytology with retrospective chart review. Results: The patient population consisted of 21 women and 1 men. The mean age was 25 years old(range 17 to 42 years). All patient had palpable neck mass and associated fever, headache, weight loss, otalgia, diarrhea, night sweating. and associated disorder is dermatitis, hepatitis B, SLE, Hashimoto's thyroiditis, albinism et al. The multiple bilateral involvement of cervical lymph node was 20 cases(91%) and multiple unilateral 18 cases(82%), multiple bilateral 2 cases(9%). Solitary involvement was 2 cases(9%), mean size of involved lymph node was 2.0cm. In laboratory tests, leukopenia 17 cases(72%), elevated ESR 12 cases(54%), elevated GOT, GPT 3 cases(13%). In CT finding, lymph nodes enhanced in homogeneous fashion, and there was no evidence of central necrosis. Conclusion: Subacute necrotizing lymphadenitis, Kikuchi's disease may be easily confused clinically, pathologically, radiologically with malignant lymphoma, inflammatory disease, granulomatous disease. We should consider open biopsy of lymph node in the patient which had unilateral multiple cervical lymph node and in laboratory tests, were leukopenia, elevated ESR, especially in young women. otherwise, result of fine needle aspiration biopsy is nonspecific, excisional biopsy is recommended in order to differentiate other disease.

  • PDF

THE STUDY ON THE PREDICTION OF THE MESIODISTAL DIAMETERS OF UNERUPTED CANINES AND PREMOLARS IN KOREAN MALE AND FEMALE (미맹출 영구 견치 및 소구치 근원심 폭경 추정에 관한 연구)

  • Hwang, Min-Sung;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.115-124
    • /
    • 2002
  • The purpose of this study was to establish regression equations and probability charts for predicting the sum of mesiodistal crown diameters of unerupted unilateral canine and premolars from the sum of mesiodistal crown diameters of four mandibular incisors in Korean male and female. The plaster casts of 162 children(75 boys and 87 girls) among the contestees in 1994-2001 Healthy Dentition Contest in Seoul were measured. Sex differences are compared and the following results were obtained: 1. Bilateral comparison of sum of widths of permanent canine and premolars showed no significant differences for either sex(p>0.05). Sum of widths of permanent canine and premolars of male were significantly larger than that of female(p<0.01). 2. Regression equations for the prediction of sum of widths of permanent canine and premolars in each sex were as follows Male ${\Sigma}Maxillary$ 345 y= 10.45+0.53x Male ${\Sigma}Mandibular$ 345 : y= 10.07+0.51x Female ${\Sigma}Maxillary$ 345 : y=12.65+0.42x Female ${\Sigma}Mandibular$ 345 : y=11.70+0.42x Male+female ${\Sigma}Maxillary$ 345 y=11.01+0.50x Male+female ${\Sigma}Mandibular$ 345 : y=9.87+0.51x

  • PDF

A Study on the Development of Product Design Database Based on Product Attributes (제품속성을 기반으로 한 제품디자인 데이터베이스 개발에 대한 기초적 연구)

  • 박정순;이건표
    • Archives of design research
    • /
    • v.12 no.2
    • /
    • pp.133-144
    • /
    • 1999
  • Considering product as mass of information, it is very critical for designers to have good means of accessing to and organizing information on products. However, designers conventionally depend on their experience, bunch of catalogues, or short visit to some fairs for gathering information on products. There are no systematically organized information for designing new products. If any, those are ones developed by market researchers or engineers who speak fundamentally different language from designers. It is needed to develop the information system through which designer can get insights on the essence of product and communicate information with various persons involved in new product planning. At first, the design information in product planning is discussed and the necessity of development of new design information system is emphasized. Then, product is understood as a composite of various attributes and a set of fundamental attributes of product is defined by surveying and summarizing existing theories of product attributes: namely technological, human, and market attributes. The possibility of new design information system is explored by analyzing various relationships between attributes of different products. Computer program 'DISPP' displays various visual information of product itself, perceptual map, trend slope, profile chart and general information of manufacturer, style, color, price, size. Finally, findings of thesis are concluded and further prospects of the study are proposed.

  • PDF