컴퓨터 비젼 방법을 이용한 3차원 물체 위치 결정에 관한 연구 (A Study on the Determination of 3-D Object's Position Based on Computer Vision Method)

  • 김경석
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.26-34
    • /
    • 1999
  • This study shows an alternative method for the determination of object's position, based on a computer vision method. This approach develops the vision system model to define the reciprocal relationship between the 3-D real space and 2-D image plane. The developed model involves the bilinear six-view parameters, which is estimated using the relationship between the camera space location and real coordinates of known position. Based on estimated parameters in independent cameras, the position of unknown object is accomplished using a sequential estimation scheme that permits data of unknown points in each of the 2-D image plane of cameras. This vision control methods the robust and reliable, which overcomes the difficulties of the conventional research such as precise calibration of the vision sensor, exact kinematic modeling of the robot, and correct knowledge of the relative positions and orientation of the robot and CCD camera. Finally, the developed vision control method is tested experimentally by performing determination of object position in the space using computer vision system. These results show the presented method is precise and compatible.

  • PDF

6자유도 측정 장치를 이용한 병렬 기구의 캘리브레이션 실험 결과 (Experimental Results on Kinematic Calibration of Parallel Manipulator using 6 DOF Measurement Device)

  • 압둘 라우프;아슬람 퍼베즈;김현호;류제하
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.197-203
    • /
    • 2005
  • This paper presents kinematic calibration of parallel manipulators with partial pose measurements using a device that measures a rotation of the end-effector along with its position. The device contains an LVDT, a biaxial inclinometer, and a rotary sensor and facilitates automation of the measurement procedure. The device is designed in a modular fashion and links of different lengths can be used. The additional kinematic parameters required for the measurement device are discussed, kinematic relations are derived, and cost function is established to perform calibration with the proposed device. The study is performed for a six degree-of-freedom(DOF) fully parallel HexaSlide Mechanism(HSM). Experimental results show significant improvement in the accuracy of the HSM.

  • PDF

Relationship between vertical components of maxillary molar and craniofacial frame in normal occlusion: Cephalometric calibration on the vertical axis of coordinates

  • Han, Ah-Reum;Kim, Jongtae;Yang, Il-Hyung
    • 대한치과교정학회지
    • /
    • 제51권1호
    • /
    • pp.15-22
    • /
    • 2021
  • Objective: The aim of this study was to evaluate the correlation between the vertical position of maxillary first molar and vertical skeletal measurements in lateral cephalograms by using new linear measurements on the vertical axis of coordinates with calibration. Methods: The vertical position of maxillary first molar (U6-SN), and the conventionally used variables (ConV) and the newly derived linear variables (NwLin) for vertical skeletal patterns were measured in the lateral cephalograms of 103 Korean adults with normal occlusions. Pearson correlation analyses and multiple linear regression analyses were performed with and without calibration using the anterior and posterior cranial base (ACB and PCB, respectively) lengths to identify variables related to U6-SN. Results: The PCB-calibrated statistics showed the best power of explanation. ConV indicating skeletal hyperdivergency was significantly correlated with U6-SN. Six NwLin regarding the position of palatal plane were positively correlated with U6-SN. Each multiple linear regression analysis generated a two-variable model: sella and nasion to palatal plane. Among the three models, the PCB-calibrated model yielded highest adjusted R2 value, 0.880. Conclusions: U6-SN could be determined by the vertical position of the maxilla, which could then be used to plan the amount of molar intrusion and estimate its clinical stability. Cephalometric calibration on the vertical axis of coordinates by using PCB for vertical linear measurements could strengthen the analysis itself.

3차원 초음파 시스템의 캘리브레이션 방법 (Calibration Technique for Freehand 3-D Ultrasound System)

  • 황면중
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6066-6071
    • /
    • 2013
  • 본 논문에서는 의료용 초음파를 이용하는 로봇 시스템을 위한 3차원 캘리브레이션 방법을 제안한다. 고정된 기준점을 구성하기 위한 캘리브레이션 블록을 제작한 후 옵티컬 트래커(optical tracker)를 이용하여 초음파 프루브(probe)의 위치와 기준점의 위치를 측정한다. 초음파 영상의 픽셀 좌표와 센서로 측정된 위치를 비교하여 6개의 파라미터로 이루어진 초음파 프루브와 영상 내의 픽셀 좌표와의 관계 행렬을 구하고 2개의 파라미터로 이루어진 스케일링 행렬을 계산한다. 정밀한 캘리브레이션을 위해 캘리브레이션 블록 내부 모양과 매질 선택에 대한 적절성을 실험을 통해 검증한다. 제안된 방법은 간단한 형태의 캘리브레이션 블록과 옵티컬 트래커를 사용하여 설치에 많은 시간이 필요하지 않는 장점이 있기 때문에 초음파 영상을 이용하는 로봇 작업에 널리 적용이 가능하다.

A New Device and Procedure for Kinematic Calibration of Parallel Manipulators

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1615-1620
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise. Intrinsic inaccuracies of the device can significantly deteriorate the calibration results. A measurement procedure is proposed and formulations of cost functions are discussed to prevent propagation of the inaccuracies to the calibration results.

  • PDF

A Compensator to Advance Gyro-Free INS Precision

  • Hung Chao-Yu;Fang Chun-Min;Lee Sou-Chen
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.351-358
    • /
    • 2006
  • The proposed inertial measurement unit (IMU) is composed of accelerometers only. It can determine a vehicle's position and attitude, which is the Gyro-free INS. The Gyro-free INS error is deeply affected by the sensor bias, scale factor and misalignment. However, these parameters can be obtained in the laboratory. After these misalignments are corrected, the Gyro-free strap-down INS could be more accurate. This paper presents a compensator design for the strap-down six-accelerometer INS to correct misalignment. A calibration experiment is taken to get the error parameters. A simulation results show that it will decrease the INS error to enhance the performance after compensation.

새로운 측정장비를 이용한 병렬구조 로봇의 보정에 관한 (Calibration of Parallel Manipulators using a New Measurement Device)

  • 압둘라우프;김성관;류제하
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1494-1499
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can be used to identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise.

  • PDF

로봇자세 측정용 와이어 병렬메카니즘의 기구학적 해석 (Kinematic analysis of the wire parallel mechanism for robot pose measurement)

  • 정재원;김수현;곽윤근
    • 대한기계학회논문집A
    • /
    • 제21권12호
    • /
    • pp.2146-2155
    • /
    • 1997
  • This paper presents the Wire Parallel Mechanism for robot pose measurement which can be used to robot calibration. It is constructed with six parallel links using wire. The position and orientation of the end effector of a robot are calculated from the wire length that measured by the encoder. The unique solution is obtained from a Newton-Raphson method and geometric configuration of the mechanism, also the method to estimate a measuring space is presented. Through the simulations, it is verified that the proposed mechanism can measure a robot pose, and has a large measuring space. In conclusion, it can be used effectively in a robot pose measurement with little cost and effort.