• 제목/요약/키워드: Six step control

검색결과 124건 처리시간 0.026초

음성을 이용한 후두암의 집단선별검사 (Acoustic screening test for laryngeal cancer)

  • 박헌수
    • 대한기관식도과학회지
    • /
    • 제7권2호
    • /
    • pp.161-167
    • /
    • 2001
  • Background and Objectives: Total laryngectomy is often required for advanced cases. But this operation induced the many inconvenience of basic daily life. Early diagnosis of laryngeal cancer is very important to prevent from this disastrous condition. In this point of view, mass screening test for early detection of laryngeal cancer is necessary. Screening test using voice has many advantages such as simple, less interventional. Voice collection by Automatic Response System(ARS) is comfortable and easy to got acoustic sample. Thus author tried to got the acoustic parameters which can differentiate normal, benign. and malignant laryngeal diseases and also checked the availability of parameters on neural network system. Materials and Methods: Author has evaluated the voice from 17 laryngeal cancer patients and 45 benign laryngeal disease patients who visited at Department of Otolaryngology, Pusan National University Hospital from May 1998 to April 2001, and 15 normal control. Author chose the sir Parameters (Jitt. vFo, Shim, vAm, NHR, SPI) that was thought to be related with voice collected by ARS among thirty-three parameters analysed by a Multi-Dimensional Voice Program (MDVP). Two-step neural network was used for the availability of six parameters. Results: The detection rate of normal voice by ARS voice analysis is 78.5% and detection rate of abnormal voice was 97.1 o/o. Among abnormal voice, the detection rate of benign laryngeal diseases and laryngeal cancers were 82.4 o/o, 70.6% respectively. Conclusion: Author concluded that six parameters and Matlab based neural network software may be effective in development of acoustic screening system for laryngeal cancer and further study should be necessary for development of new acoustic parameters.

  • PDF

Post 공간형성이 치근단 폐쇄성에 미치는 영향에 관한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY ON THE EFFECT OF POST SPACE PREPARATION ON THE APICAL SEAL OF ROOT CANAL)

  • 임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.611-620
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of post space preparation on apical sealing according to the methods and time of gutta percha removal. Forty six extracted single rooted teeth were selected for this study. Forty teeth were used as experimental groups and six teeth as control groups. Forty teeth were routinely prepared by step-back method and obturated with gutta percha cones and zinc oxide-eugenol cement using lateral condensation. All obturated teeth were divided into 4 groups of 10 teeth each. In each group of 1, 2, 3, heated plugger, gate glidden drill and chloroform and K-file were used respectively for post space preparation by removing the gutta percha immediately after obturation. In group 4, post space were prepared with gate glidden drill one week after obturation. In all experimental groups, the post space were prepared so that 4mm of apical gutta percha remained. After post space preparation, apical leakage were measured with electrochemical method for 28 days and analyzed statistically. The following results were obtained ; 1. No statistically significant differences in apical leakage were occured among the experimental groups using heated plugger, gate glidden drill and chloroform and K-file to remove the gutta percha immediately after obturation. 2. No significant difference in apical leakage was found between the teeth prepared post space immediately after obturation and those prepared 1 week after obturation. 3. In all experimental groups, the apical leakage was increased with time passage regardless of the post space preparation time and the gutta percha removal techniques.

  • PDF

Performance of Broiler Chickens Fed Low Protein, Limiting Amino Acid Supplemented Diets Formulated Either on Total or Standardized Ileal Digestible Amino Acid Basis

  • Kumar, C. Basavanta;Gloridoss, R.G.;Singh, K.C.;Prabhu, T.M.;Suresh, B.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권11호
    • /
    • pp.1616-1624
    • /
    • 2016
  • The aim of present experiment was to investigate the effect of protein reduction in commercial broiler chicken rations with incorporation of de-oiled rice bran (DORB) and supplementation of limiting amino acids (valine, isoleucine, and/or tryptophan) with ration formulation either on total amino acid (TAA) or standardized ileal digestible amino acids (SIDAA). The experimental design consisted of $T_1$, TAA control; $T_2$ and $T_3$, 0.75% and 1.5% protein reduction by 3% and 6% DORB incorporation, respectively by replacing soybean meal with supplemental limiting amino acids to meet TAA requirement; $T_4$, SIDAA control, $T_5$ and $T_6$, 0.75% and 1.5% protein reduction by DORB incorporation (3% and 6%) with supplemental limiting amino acids on SIDAA basis. A total of 360 dold fast growing broiler chicks (Vencobb-400) were divided into 36 homogenous groups of ten chicks each, and six dietary treatments described were allocated randomly with six replications. During 42 days trial, the feed intake was significantly (p<0.05) reduced by TAA factor compared to SIDAA factor and protein factor significantly (p<0.05) reduced the feed intake at 1.5% reduction compared to normal protein group. This was observed only during pre-starter phase but not thereafter. The cumulative body weight gain (BWG) was significantly (p<0.05) reduced in TAA formulations with protein step-down of 1.5% ($T_3$, 1,993 g) compared to control ($T_1$, 2,067 g), while under SIDAA formulations, BWG was not affected with protein reduction of 1.5% ($T_6$, 2,076 g) compared to $T_4$ (2,129 g). The feed conversion ratio (FCR) was significantly (p<0.05) reduced in both TAA and SIDAA formulations with 1.5% protein step-down ($T_3$, 1.741; $T_6$, 1.704) compared to respective controls ($T_1$, 1.696; $T_4$, 1.663). The SIDAA formulation revealed significantly (p<0.05) higher BWG (2,095 g) and better FCR (1.684) compared to TAA formulation (2,028 g; 1.721). Intake of crude protein and all limiting amino acids (SID basis) was higher in SIDAA group than TAA group with resultant higher nitrogen retention (4.438 vs 4.027 g/bird/d). The nitrogen excretion was minimized with 1.5% protein reduction (1.608 g/bird) compared to normal protein group (1.794 g/bird). The serum uric acid concentration was significantly reduced in $T_3$ (9.45 mg/dL) as compared to $T_4$ (10.75 mg/dL). All carcass parameters were significantly (p<0.05) higher in SIDAA formulation over TAA formulation and 1.5% protein reduction significantly reduced carcass, breast and thigh yields. In conclusion, the dietary protein can be reduced by 0.75% with TAA formulation and 1.5% with SIDAA formulation through DORB incorporation and supplementation of limiting amino acids and among formulations, SIDAA formulation was better than TAA formulation.

전기자동차용 FB-ZVS PWM DC/DC 변환기의 해석 (Analysis of a FB-ZVS PWM DC/DC Converter for Electric Vehicles)

  • 이동근;윤덕용;홍순찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.461-463
    • /
    • 1996
  • A FB-ZVS(Full Bridge Zero Voltage Switching) PWM DC/DC converter for electric vehicles is analyzed in this paper. The converter considered is a step-down DC/DC converter with the ratings of 3l2/I3.5V and 1.35kW. The steady state analysis of this converter is divided into six operating modes. Digital simulations using PSPICE are carried out to verify the steady-state analysis.

  • PDF

6시그마 방법론 활용을 통한 모터 수명 개선 (Motor's Lifetime Improvement Using Six Sigma Methodology)

  • 이장희;이문수
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 추계 학술대회
    • /
    • pp.170-173
    • /
    • 2006
  • 본 연구는 모터 제조회사에서 모터 수명 향상을 위해 식스 시그마 방법론에 근거하여 개선한 사례연구이다. 모터 수명 향상 활동을 추진하기 위해 본 연구에서는 제조부문의 식스 시그마 프로젝트 추진절차인 Define-Measure-Analyze-Improve-Control 절차를 수행했다. 모터 수명과 연관된 불량 유형을 정의하고 불량 측정 시스템에 대한 계측시스템의 정도평가, 불량유형요인효과분석, 4Step Diagram과 같은 분석기법을 활용하여 수명에 중요한 요인도출, 중요 요인의 개선대책 수립 및 개선 확인 후 최종적으로 지속적인 신뢰성 관리 방안을 수립하였다. 본 연구는 대부분 영세한 모터 제조업체에서 모터수명 관리를 위해 많은 투자를 할 수 없는 현황을 고려할 때 신뢰성 관리의 효율적 방안을 제시한다.

  • PDF

Expression Analysis of phbC Coding for Poly-3-hydroxybutyrate (PHB) Synthase of Rhodobacter sphaeroides

  • Kho, Dhong-Hyo;Yang, Jai-Myung;Kim, Kun-Soo;Lee, Jeong-Kug
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권2호
    • /
    • pp.310-316
    • /
    • 2001
  • Poly-3-hydroxybutyrate (PHB) synthase catalyzed the last enzymic step to synthesize the intracellular PHB of Rhodobacter sphaeroides. No PHB was detected when the phbC coding for PhB synthase was interrupted, and its expression was regulated at the level of transcription. The cellular PHB content increased about four- to six-fold during the growth transition from the exponential to the early stationary phase under both aerobic and photoheterotrophic conditions. The PHB content during the aerobic growth seemed to be determined by the PhB synthase activity. However, the PHB synthase activity of photoheterotrophically grown cells did not correlate with the PhB content, suggesting a photoheterotrophic regulation different from the aerobic control. Thus, the PHB content of R. sphaeroides was regulated at the transcription level only under aerobic conditions.

  • PDF

DSP를 이용한 Brushless DC 모터의 초고속 센서리스 제어 (High Speed Sensorless Control of Brushless DC Motor Using DSP)

  • 김경화;정문종;김태덕;김영만
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.37-40
    • /
    • 1999
  • DSP를 이용한 Brushless DC (BLDC) 모터의 초고속 센서리스 제어 기법 및 그 결과가 제시된다. 초고속 BLDC 모터의 센서리스 제어를 위해서 주 제어기로 DSP TMS320C240이 사용되며 제어 기법으로는 Pulse Amplitude Modulation(PAM) 기법이 사용된다. RAM 제어 기법을 사용함으로서 인버터는 six-step 방식으로 구동되며 속도 제어는 인버터 DC 링크 앞 단 쵸퍼의 전압 제어에 의해 이루어진다. 회전자 위치는 역기전력 센싱 방식에 의해 추정되며 TMS320C240의 Event Manager Module에 입력되어 Commutation 위치 및 속도가 계산된다. 계산된 속도는 디지털 PI 제어 알고리즘에 의해 처리되며 제어기의 출력은 쵸퍼의 duty 비를 변화시킨다. 개발된 DSP 제어 보드 및 제어 알고리즘의 성능을 시험하기 위해 실험이 수행되었으며 전체 제어 알고리즘은 DSP TMS320C240의 어셈블리 프로그램에 의해 구현된다. 결과로 최고 속도 50000 [rpm]에서 이상적인 응답 특성을 얻을 수 있었다.

  • PDF

THE CONTROL OF THIRD HARMONICS INJECTED PWM INVERTER IN OVER MODULATION MODE

  • Kim, Young-Real;Kim, Yuen-Chung;Kim, Jae-Mun;Won, Chung-Yuen
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.362-365
    • /
    • 1998
  • A new modified command voltage of the third harmonics injected PWM inverter is proposed in overmodulation mode. By analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonic injected PWM inverter comparative to six-step inverter continuously in over modulation mode.

  • PDF

A Study on the High Performance PWM Technique for a Propulsion System of Railway

  • Lee, K.J.;Jeong, M.K.;Bang, L.S.;Seo, K.D.;Kim, N.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.425-430
    • /
    • 1998
  • This paper presents a high performance low switching PWM technique for the propulsion system of railway such as subway and high speed train. In order to achieve the continuous voltage control to six-step and a low harmonics with low switching frequency under 500Hz, the synchronous PWM technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method are showed by the digital simulation and the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons railway vehicles.

  • PDF

Simplified SVPWM that Integrates Overmodulation and Neutral Point Potential Control

  • Zhu, Rong-Wu;Wu, Xiao-Jie
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.926-936
    • /
    • 2014
  • A simplified and effective space vector pulse-width modulation (SVPWM) algorithm with two and three levels for three-phase voltage-source converters is proposed in this study. The proposed SVPWM algorithm only uses several linear calculations on three-phase modulated voltages without any complicated trigonometric calculations adopted by conventional SVPWM. This simplified SVPWM also avoids choosing the vector sector required by conventional SVPWM. A two-level overmodulation scheme is integrated into the proposed two-level SVPMW to generate the output voltage that increases from a linear region to a six-step state with a smoothly linear transition characteristic and a simple overmodulation process without a lookup table and complicated nonlinear functions. The three-level SVPWM with a proportional-integral controller effectively balances the neutral point potential of the neutral point clamped converter. Results from the simulation in MATLAB/Simulink and the experiment based on a digital signal processor are provided to clearly demonstrate the validity and effectiveness of the proposed strategies.