• 제목/요약/키워드: Site contamination

검색결과 393건 처리시간 0.023초

토양오염에 대한 정화책임의 주체 (A concerned party of purification liability for soil pollution)

  • 조은래
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1999년도 추계학술발표회
    • /
    • pp.53-56
    • /
    • 1999
  • The concerned party of purification liability in a soil pollution is an owner or occupant of a contaminated site. But when we don't appoint the polluter or he can't do a cleanup, municipal put in effect the purification. In such a case, another parties who are related to the contamination ought to the liability. The province of responsible parties, therefore, is required to extend to an owner or operator of a facility, a carrier and lender

  • PDF

Application of In Situ Measurement for Site Remediation and Final Status Survey of Decommissioning KRR Site

  • Hong, Sang Bum;Nam, Jong Soo;Choi, Yong Suk;Seo, Bum Kyoung;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.173-178
    • /
    • 2016
  • Background: In situ gamma spectrometry has been used to measure environmental radiation, assumptions are usually made about the depth distribution of the radionuclides of interest in the soil. The main limitation of in situ gamma spectrometry lies in determining the depth distribution of radionuclides. The objective of this study is to develop a method for subsurface characterization by in situ measurement. Materials and Methods: The peak to valley method based on the ratio of counting rate between the photoelectric peak and Compton region was applied to identify the depth distribution. The peak to valley method could be applied to establish the relation between the spectrally derived coefficients (Q) with relaxation mass per unit area (${\beta}$) for various depth distribution in soil. The in situ measurement results were verified by MCNP simulation and calculated correlation equation. In order to compare the depth distributions and contamination levels in decommissioning KRR site, in situ measurement and sampling results were compared. Results and Discussion: The in situ measurement results and MCNP simulation results show a good correlation for laboratory measurement. The simulation relationship between Q and source burial for the source layers have exponential relationship for a variety depth distributions. We applied the peak to valley method to contaminated decommissioning KRR site to determine a depth distribution and initial activity without sampling. The observed results has a good correlation, relative error between in situ measurement with sampling result is around 7% for depth distribution and 4% for initial activity. Conclusion: In this study, the vertical activity distribution and initial activity of $^{137}Cs$ could be identifying directly through in situ measurement. Therefore, the peak to valley method demonstrated good potential for assessment of the residual radioactivity for site remediation in decommissioning and contaminated site.

해체사업의 최종현황조사를 위한 MARSSIM 적용 (Application of MARSSIM for Final Status Survey of the Decommissioning Project)

  • 홍상범;이기원;박진호;정운수
    • 방사성폐기물학회지
    • /
    • 제9권2호
    • /
    • pp.107-111
    • /
    • 2011
  • 해체의 최종단계는 대상 부지 및 건물을 규제로부터 제외하는 것이다. MARSSIM은 부지를 개방하기 위한 최종현황조사를 수행함에 있어 요구되는 자료의 수집 등의 다양한 요건을 만족키기 위한 총괄적인 지침을 제공한다. 연구로 해체 후 부지 및 건물의 최종현황조사를 위해 MARSSIM에서 제시하고 있는 방법을 적용하였다. 연구로 부지의 특성을 반영한 개방기준을 도출하기 위해 RESRAD 및 RESRAD-Build 전산코드를 이용하여 부지 및 건물에 대해서 계산하였다. 부지 및 건물의 조사설계(Survey Design)를 위해서 잠재적 오염도 및 측정 결과를 활용하여 조사구역을 구분하였고, 개략조사 및 특성조사를 통해 수집된 다양한 결과에 기초하여 통계학적 검사를 통해 조사구역 별로 요구되는 시료의 수를 산정하게 된다. 측정된 결과에 기초하여 연구로 최종 개방기준에 만족하는 것으로 평가되었다.

새로운 생물농축 기법에 의한 PAHs의 오염도 확인 (Use of New Passive Sampler to Assess PAHs Contamination)

  • 박정규;황인영;문성환;정홍배
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.171-179
    • /
    • 2001
  • A new passive sampler was developed, improving SPMD (Semipermeable Membrane Devices) that contained triolein in nonporous, low-density polyethylene layflat tubing. Experiments to measure PAHs concentration were carried out at four sites (Dukpo, Sochi, Sohwonggando, Yeonmok) on the southern coast of Korea that were contaminated by oil spills. Passive samplers were deployed at 4 and 8 week intervals at each site. Results showed that bioconcentration levels of PAHs were increased in proportion to exposure duration from all sample sites and accumulation in the passive sampler was much higher than in biota at the Dukpo site. Results of these tests suggest that new passive sampler is a useful tool for measuring bioconcentration organic compounds in aquatic environments.

  • PDF

토양에 유출된 유류의 오염도 조사에 관한 사례연구 (Case Study of Oil Spills in Soil; Oil Concentration Distribution in Soil)

  • 박규홍;박준범
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.31-39
    • /
    • 1997
  • Between 40,000 and 60,000 liters of light oil were spilled when an underground pipe broke at a newly constructed landfill site in coastal area, Korea. Methods were presented to examine the subsurface distribution of the contaminants in hydrocarbon-contaminated soil. As results, large quantities of oil and grease were found to have migrated horizontally at the site. Oil and grease plume at concentrations of 38-88 mg/kg was formed horizontally through silty sand with gravel fill and the vertical movement of the contaminants was thought to be limited to groundwater level between 2 and 4 m corresponding to sea water level. Right after finding the leakage area, the early action of excavation and pumping out the mixture of groundwater and oil was taken and it was proved to be very effective for preventing further contamination. Two months after the leakage, oil and grease in sea water sample near contaminated area was not detectable.

  • PDF

토양오염 복원을 위한 EMPLUX를 사용한 새로운 방법에 대한 연구 (A Study on the New Method by EMPLUX for Soil-Remediation(1))

  • 김정성
    • 한국환경과학회지
    • /
    • 제16권12호
    • /
    • pp.1325-1335
    • /
    • 2007
  • The utility of soil-gas surveys is directly proportional to their accuracy in reflecting and representing changes in the subsurface concentrations of source compounds. Passive soil-gas vapor-phase is merely a fractional trace of the source, so, as a matter of convenience, the units used in reporting detection values from EMFLUX surveys are smaller than those employed for source-compound concentrations. According to the Leaking Underground Storage Tank(LUST) Program Annual Report, approximately 16 U.S. million dollars were spent for environmental site investigations at over 1,600 Underground Storage Tank(UST) sites and approximately over 1,000 acres of land was characterized and remediated in the State of Illinois in the year of 2003 alone. The main purpose of this study is to propose an idea to significantly reduce the site investigation cost by utilizing a passive soil-gas survey and conventional intrusive drilling method and to fully define the three dimensional characteristics of subsurface contamination from two industrial drycleaning facilities.

토양중 Thiolane 농도 결정방법 (Determination of Thiolane Concentration from Soils by Purging Apparatus)

  • Chang Gyun Kim;William Paul Clarke;David Lockington
    • 한국토양환경학회지
    • /
    • 제4권2호
    • /
    • pp.3-10
    • /
    • 1999
  • The unknown amount of thiolane retained on different soil matrix was characterized by employing an uniquely designed glass vessel, which was forced to purge the prepared slurry sample so that thiolane may diffuse into Tenax/charcoal tube. Thiolane can be recovered ranging from approximately 89 % at 1 ppm regardless of soil types, which was not consequently affected by potential biodegradation during sample preparation. For 5 ppm. thiolane is more recoverable up to 92 % for sand, whereas it was poorly recovered as low as 85 % for clay. It strongly suggests that controls should be considered when soil types varied in a concerned area. The technique was eventually capable of determination of thiolane for the samples taken from the site which led to be taken into consideration for proper site remediation.

  • PDF

Radionuclide-Specific Exposure Pathway Analysis of Kori Unit 1 Containment Building Surface

  • Byon, Jihyang;Park, Sangjune;Ahn, Seokyoung
    • 방사성폐기물학회지
    • /
    • 제18권3호
    • /
    • pp.347-354
    • /
    • 2020
  • Site characterization for decommissioning Kori Unit 1 is ongoing in South Korea after 40 years of successful operation. Kori Unit 1's containment building is assumed to be mostly radioactively contaminated, and therefore radiation exposure management and detailed contamination investigation are required for decommissioning and dismantling it safely. In this study, site-specific Derived Concentration Guideline Levels (DCGLs) were derived using the residual radioactivity risk evaluation tool, RESRAD-BUILD code. A conceptual model of containment building for Kori Unit 1 was set up and limited occupational worker building inspection scenario was applied. Depending on the source location, the maximum contribution source and exposure pathway of each radionuclide were analyzed. The contribution of radionuclides to dose and exposure pathways, by source location, is expected to serve as basic data in the assessment criteria of survey areas and classification of impact areas during further decommissioning and decontamination of sites.

논 지역 시설재배지에서의 유기물 및 영양염류 유출 특성 (Runoff characteristics of organic matters and nutrients from greenhouse site in paddy field area)

  • 이근후;옥정훈;유시창;유찬
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.604-609
    • /
    • 2005
  • Runoff characteristics of organic matters and nutrients from greenhouse site in paddy field area were investigated during the irrigation period in 2004. The greenhouse selected which situated near the Nam river, Jinju, Korea used the ground water as the irrigation purpose. And, the rotating system of paddy field to upland was adapted as a cropping system which is a typical practice in this area. Various items such as total phosphorus(T-P), total nitrogen(T-N), dissolved oxygen(DO), BOD, etc. were observed to figure out the seasonal and spatial variation in the study sites. it was found that the risk of water pollution due to the contamination of nutrients in canals in green house sites, and their neighbouring small sized streams are much higher than those in ordinary paddy field areas. Further surveys and investigations are required to find out the counter measures to reduce water pollution occurred in greenhouse sites.

  • PDF

유기물의 토양 개량 효과 측정 (The Measurement of Soil Conditioning Effects of Organic Materials)

  • 주영규
    • 아시안잔디학회지
    • /
    • 제7권1호
    • /
    • pp.13-18
    • /
    • 1993
  • Much attention has been given recently to solve the environmental contamination in golf courses Changing to culture practice rather than chemical practice that depends on pesticides and fertilizers is a hot issue in golf courses or grasslands. Organic soil conditioners improve soil-plant envirormental conditions rich in physical properties. In this study, measuring systems to evaluate soil conditioning effects were set up for on-site purpose. After establishing the methodology for evaluating soil conditioner effects, 2 kinds of organic conditioners were rested for examination. The systems for the methodology included a set of simulating equipment for field capacity, an impact type soil column compactor, and an infiltration-percolation system. Test results using the systems showed bulk density and infiltration rate of mixed soil were decreased at highter rates of conditioner, but total porocities were increased. Increased porocities were most capillary pore space which has a positive effect on soil water potential. The systems and methodology in this study seem to have an efficiency to measure the effects of soil conditioner on site purpose.

  • PDF