OVERVIEW OF KOMPSAT APPLICATION PRODUCT VALIDATION SITE AND THE RELATED ACTIVITIES

  • Lee, Kwang-Jae;Youn, Bo-Yeol;Kim, Duk-Jin;Kim, Youn-Soo
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.122-125
    • /
    • 2007
  • In recent years, there has been an increasing demand for improved accuracy and reliability of Earth Observation Satellite (EOS) data. Most of the data users in the field of remote sensing require understanding of product accuracy and uncertainty. Especially, EOS application products should be validated for practical application in the field. In order to evaluate the availability and applicability of application products, it will be necessary to establish a systematic validation system including techniques, equipments, ground truth data, etc. The Product Validation Site (PVS) for generation and validation of KOMPSAT application products was designed and established with various in-situ equipment and dataset. This paper presents the status of PVS and summarizes some results from experiment studies at PVS.

  • PDF

Design of a Biconical Antenna with Cylindrical Loads for EMI Test Site Validation above 1 GHz

  • Kong, Sung-Sik;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, a biconical type antenna is proposed for EMI test site validation above 1 GHz. To achieve broadband and omni-directional radiation patterns required by international standard(CISPR), the proposed antenna consists of general bicones with cylindrical loads and adopts side feeding method to minimize the influence on H-plane pattern due to feeding cable, balun, and connector. The radiation patterns of the fabricated antenna are measured and the results are compared with CISPR criteria and commercial antenna in our interest frequencies. Although the proposed antenna has a few problems in frequency range of 1 GHz to 2 GHz, it has relatively better performance than commercial antenna.

Validation of Radioanalytical Techniques for Nuclear Waste Characterisation

  • Warwick, Phillip E.
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.363-373
    • /
    • 2019
  • Waste characterisation associated with nuclear site decommissioning relies on radiochemical analysis of a diverse range of sample types, requiring extensive validation of analytical techniques using matrix-matched materials. The absence of relevant reference materials has hindered robust method development and validation. The paper discusses how method validation in support of nuclear waste characterisation can be achieved without using reference materials. The key stages in an analytical procedure are evaluated and a multi-stage approach is proposed with the ultimate aim of determining an operational envelope for an analytical procedure.

Antenna for EMI Site Validation above 1 GHz (1 GHz 이상의 EMI 시험장 적합성 평가용 안테나)

  • Kong, Sung-Sik;Chung, Sam-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.65-66
    • /
    • 2006
  • In this paper, we designed and fabricated a broadband antenna for EMI site validation above 1 GHz. To develop the antenna which is satisfied omni-directional radiation pattern and broadband characteristics required by CISPR, we designed biconical type with cylindrical load. The developed antenna has good characteristics of the radiation patterns and VSWR<2 the frequency range from 1 GHz to 18 GHz.

  • PDF

Three-dimensional geostatistical modeling of subsurface stratification and SPT-N Value at dam site in South Korea

  • Mingi Kim;Choong-Ki Chung;Joung-Woo Han;Han-Saem Kim
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.29-41
    • /
    • 2023
  • The 3D geospatial modeling of geotechnical information can aid in understanding the geotechnical characteristic values of the continuous subsurface at construction sites. In this study, a geostatistical optimization model for the three-dimensional (3D) mapping of subsurface stratification and the SPT-N value based on a trial-and-error rule was developed and applied to a dam emergency spillway site in South Korea. Geospatial database development for a geotechnical investigation, reconstitution of the target grid volume, and detection of outliers in the borehole dataset were implemented prior to the 3D modeling. For the site-specific subsurface stratification of the engineering geo-layer, we developed an integration method for the borehole and geophysical survey datasets based on the geostatistical optimization procedure of ordinary kriging and sequential Gaussian simulation (SGS) by comparing their cross-validation-based prediction residuals. We also developed an optimization technique based on SGS for estimating the 3D geometry of the SPT-N value. This method involves quantitatively testing the reliability of SGS and selecting the realizations with a high estimation accuracy. Boring tests were performed for validation, and the proposed method yielded more accurate prediction results and reproduced the spatial distribution of geotechnical information more effectively than the conventional geostatistical approach.

A Analysis for Calibration Site Selection of SAR Satellite (SAR 위성 검보정 사이트 선택을 위한 분석)

  • Keum, Jung-Hoon;Ra, Sung-Woong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.659-666
    • /
    • 2009
  • CALVAL (Calibration & Validation) shall consider payloads characteristics because satellites have one and/or several payloads in order to perform their various missions. SAR satellite, one of various satellite, shall need to use special ground targets, which can reflect the radar signal to the satellite, because it can see objects with reflected radar signal. Therefore, the special ground targets, which are called generally reflector(corner reflector is the one of them) shall be installed and constructed on the ground path. The satellite must access the targets on that path. To accomplish successful calibration, the CALVAL site including corner reflectors will be surveyed and analyzed using various environment characteristics. In this paper, CALVAL site including point targets(corner reflector) for absolute radiometric calibration except one including distributed targets for relative radiometric calibration has been deeply considered.

Analysis of the Normalized Site Attenuation Using the Moment Method (정규화 시험장감쇠량의 모멘트 법 해석)

  • Ki Chai Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.48-57
    • /
    • 1993
  • The ANSI recently adopted normalized site attenuation(NSA) as a validation procedure of open area test sites. In this paper, the theoretical NSA values specified in the truth vlues of NSA were calculated for an ideal test site when tuned dipoles are used. A method of moments technique is employed to evaluate these NSA values. The calculated NSA values are more accurate than that of the ANSI.

  • PDF

AN EXPERIMENTAL STUDY ON THE ESTABLISHMENT OF PRODUCT VALIDATION SITE AND THE RELATED ACTIVITIES

  • Lee Kwangjae;Kim Younsoo;Kim Yongseung;Hoersch Bianca
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.426-429
    • /
    • 2005
  • In order to evaluate KOrea Multi-Purpose SATellite (KOMPSAT) application products and develop the multi-sensor data application technologies, the Product Validation Site (PVS) will be designed and constructed by Korea Aerospace Research Institute (KARI). Also KARl has a plan for acquisition of multi-sensor data such as ENVISAT ASAR and Project for On Board Autonomy (PROBA) Compact High Resolution Imaging Spectrometer (CHRIS) data through international cooperation with European Space Agency (ESA). These data will be utilized with KOMPSAT-2 Multi-Spectral Camera (MSC) data. KARI and ESA have identified a mutual interest in creating synergy in the joint exploitation of Earth Observation data for science and applications both in Korea and Europe. This paper summarizes the status of joint experimental studies between KARI and ESA for further applications and presents some expected results from related activities.

  • PDF

Model Parameter Determination of Industrial Co-generator Model Parameters through Filed Measurement (현장 계측을 통한 산업용 열병합 발전설비 모델 파라미터 결정)

  • Kim, Hak-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.159-165
    • /
    • 2007
  • This paper presents a method for the derivation of model parameters of a co-generation system using data measured through on-site generator characteristic testing and validates its model parameters. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. The comparisons between measured results and simulation results show good match.

Validation of the Risk Prediction Tool for Wound Infection in Abdominal Surgery Patients (복부 수술환자의 수술부위 감염 위험 예측 도구의 타당도 검증)

  • Jung, Hyun Kyoung;Lee, Eun Nam
    • Journal of Korean Critical Care Nursing
    • /
    • v.15 no.3
    • /
    • pp.75-87
    • /
    • 2022
  • Purpose : This retrospective investigation study aimed to determine the predictive validity of superficial surgical site infection assessment tools by measuring the risk score at the surgical site. Methods : This study included patients hospitalized to the general surgery department of a Hospital from January 2021 to December 31, 2021. The inclusion criteria were age ≥19 years, general abdominal surgery under general anesthesia, and hospital stay longer than 2 days. Patients who had undergone transplantation were excluded. Results : Tool validity results showed that tools including surgical time and operative procedure were more accurate than previously developed tools, with a sensitivity of 71.1%, specificity of 71.4%, positive prediction of 12.3%, negative prediction of 97.8%, and area under the curve of 0.743 (95% confidence interval, 0.678~0.745). The tool's cut-off score was 15, and the risks of infection was increased by 6.14 times at or above this cut-off point. Preoperative hair removal period, surgical wound classification, surgery time, body temperature on the second day after surgery, drainage tube type, and suture type affected the risk of infection at the surgical site. Conclusion : The incidence of healthcare-associated infections has been declining in the past decade; however, surgical site infections still account for a considerable proportion. Therefore, early identification of high-risk groups for surgical site infection is crucial for reducing the incidence of surgical site infection using appropriate management.