• Title/Summary/Keyword: Site Response Analysis

Search Result 655, Processing Time 0.024 seconds

A Study on Seismic Liquefaction Risk Map of Electric Power Utility Tunnel in South-East Korea (국내 동남권 지역의 전력구 지반에 대한 지진시 액상화 위험도 작성 연구)

  • Choi, Jae-soon;Park, Inn-Joon;Hwang, Kyengmin;Jang, Jungbum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.13-19
    • /
    • 2018
  • Following the 2016 Gyeongju earthquake, the Pohang Earthquake occurred in 2017, and the south-east region in Korea is under the threat of an earthquake. Especially, in the Pohang Earthquake, the liquefaction phenomenon occurred in the sedimentation area of the coast, and preparation of countermeasures is very important. The soil liquefaction can affect the underground facilities directly as well as various structures on the ground. Therefore, it is necessary to identify the liquefaction risk of facilities and the structures against the possible earthquakes and to prepare countermeasures to minimize them. In this study, we investigated the seismic liquefaction risk about the electric power utility tunnels in the southeast area where the earthquake occurred in Korea recently. In the analysis of seismic liquefaction risk, the earthquake with return period 1000 years and liquefaction potential index are used. The liquefaction risk analysis was conducted in two stages. In the first stage, the liquefaction risk was analyzed by calculating the liquefaction potential index using the ground survey data of the location of electric power utility tunnels in the southeast region. At that time, the seismic amplification in soil layer was considered by soil amplification factor according to the soil classification. In the second stage, the liquefaction risk analysis based on the site response analyses inputted 3 earthquake records were performed for the locations determined to be dangerous from the first step analysis, and the final liquefaction potential index was recalculated. In the analysis, the site investigation data were used from the National Geotechnical Information DB Center. Finally, it can be found that the proposed two stage assessments for liquefaction risk that the macro assessment of liquefaction risk for the underground facilities including the electric power utility tunnel in Korea is carried out at the first stage, and the second risk assessment is performed again with site response analysis for the dangerous regions of the first stage assessment is reasonable and effective.

Species Composition and Species Diversity of Moths (Lepidoptera) on Quercus mongolica forests sand Pinus densiflora forests, in Korean National Long-term Ecological Research Sites (Mt. Nam, Mt. Jiri, Mt. Wolak) (국가 장기 생태 연구지(남산, 지리산, 월악산)의 신갈나무림과 소나무림에서 포획된 나방류의 종조성 및 종다양도)

  • Yi, Hoon-Bok;Kim, Hyun-Jung
    • Korean journal of applied entomology
    • /
    • v.49 no.2
    • /
    • pp.105-113
    • /
    • 2010
  • Moths were collected using a 22W UV black light trap in June through September in 2005 and May, June, August and September in 2006. The study sites were Namsan (Mt. Nam), Jirisan (Mt. Jiri), Woraksan (Mt. Worak) which are part of the Korean National Long Term Ecological Research (KNLTER). There were two common forest communities, Quercus mongolica and Pinus densiflora. The purpose of this study was to compare species diversity of the major plant feeding Lepidoptera in the two forest types at the regional KNLTER sites. We collected a total of 435 species from the KLTER sites in 2005 and 2006. Abundance of moths was highest at Woraksan (Mt. Worak) followed by Jirisan (Mt. Jiri). The Namsan (Mt. Nam) site had the lowest, with five families (Arctiidae, Geometridae, Noctuidae, Notodontidae, and Pyralidae). Analysis of variance (ANOVA) showed statistically significant differences at sampling date in species abundance as a response variable and at site in species richness as another response variable. Although we expected a distinct cluster with the forest type at each study site, one of ordination analyses, nonmetric multidimensional scaling (NMS), showed distinct clusters with the moth assemblages at each site only but NMS did not show any distinct cluster with the different forest types at each site as we expected.

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

Application of neural networks and an adapted wavelet packet for generating artificial ground motion

  • Asadi, A.;Fadavi, M.;Bagheri, A.;Ghodrati Amiri, G.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.575-592
    • /
    • 2011
  • For seismic resistant design of critical structures, a dynamic analysis, either response spectrum or time history is frequently required. Owing to the lack of recorded data and the randomness of earthquake ground motion that may be experienced by structure in the future, usually it is difficult to obtain recorded data which fit the requirements (site type, epicenteral distance, etc.) well. Therefore, the artificial seismic records are widely used in seismic designs, verification of seismic capacity and seismic assessment of structures. The purpose of this paper is to develop a numerical method using Artificial Neural Network (ANN) and wavelet packet transform in best basis method which is presented for the decomposition of artificial earthquake records consistent with any arbitrarily specified target response spectra requirements. The ground motion has been modeled as a non-stationary process using wavelet packet. This study shows that the procedure using ANN-based models and wavelet packets in best-basis method are applicable to generate artificial earthquakes compatible with any response spectra. Several numerical examples are given to verify the developed model.

Development of Machine Learning Based Seismic Response Prediction Model for Shear Wall Structure considering Aging Deteriorations (경년열화를 고려한 전단벽 구조물의 기계학습 기반 지진응답 예측모델 개발)

  • Kim, Hyun-Su;Kim, Yukyung;Lee, So Yeon;Jang, Jun Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.2
    • /
    • pp.83-90
    • /
    • 2024
  • Machine learning is widely applied to various engineering fields. In structural engineering area, machine learning is generally used to predict structural responses of building structures. The aging deterioration of reinforced concrete structure affects its structural behavior. Therefore, the aging deterioration of R.C. structure should be consider to exactly predict seismic responses of the structure. In this study, the machine learning based seismic response prediction model was developed. To this end, four machine learning algorithms were employed and prediction performance of each algorithm was compared. A 3-story coupled shear wall structure was selected as an example structure for numerical simulation. Artificial ground motions were generated based on domestic site characteristics. Elastic modulus, damping ratio and density were changed to considering concrete degradation due to chloride penetration and carbonation, etc. Various intensity measures were used input parameters of the training database. Performance evaluation was performed using metrics like root mean square error, mean square error, mean absolute error, and coefficient of determination. The optimization of hyperparameters was achieved through k-fold cross-validation and grid search techniques. The analysis results show that neural networks and extreme gradient boosting algorithms present good prediction performance.

Characteristics Analysis of Seasonal Construction Site Fall Accident using Text Mining (텍스트 마이닝을 활용한 계절별 건설현장 추락사고 특징 분석)

  • Kim, Joon-Soo;Kim, Byung-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.113-121
    • /
    • 2019
  • The death rate of industrial accidents per 10,000 people in Korea is two to three times higher than that of major countries. Falling accidents at the construction site happened to have caused the most deaths. Analysis of existing research and measures by national institutions showed that the industrial accident management concentrated on falling accidents was insufficient and the seasonal safety management measures were not enough. There is thus the need for research that provides detailed and enough information on falling accidents. This study, therefore, aims to overcome the limitations of existing research and safety management accident response using a methodology that provides the necessary information for the prevention of fall accidents by deriving seasonal crash characteristics of the construction site. In order to provide enough information, 387 cases of seasonal construction site falling were collected, which describes the causal relationship of accidents. Text mining using principal component analysis and cluster analysis was carried out. The analysis showed that: In the spring, snowfall and unreasonable operation of equipment including lifts were the major cause. In summer, most accidents were caused by form, insufficient safety inspection, and installation work. In autumn, weather factors such as wind and typhoon were the cause. In winter, material transportation, exterior wall work, and ignore safety precautions were the cause of the crash.

Analysis of Amplification Factor Spectrum Using Strong Ground Motions Compatible to the Domestic Seismotectonic Characteristics (유사 강지진동을 이용한 수평 및 수직지반응답의 Amplification Factor 스펙트럼 분석)

  • 김준경;박창업;조봉곤;지헌철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.25-29
    • /
    • 1997
  • Amplication factor spectrum, using the observed strong ground motions database, has been obtained and compared with Standard Response Spectrum. The observed ground motions from the Miramichi, Nohanni, Sagueray and New Madrid Earthquake (19 vertical components, 36 horizontal components), which are estimated to represent domestic seismotectonic characteristics such as seismic sources, attenuation, and site effect, are used for the analysis of amplification factor spectrum. Amplication factors have been calculated by comparing the observed peak ground motions with results form responses to the observed horizontal and vertical ground motions. The comparison shows that the amplification factors resultant from this study exceed those of Standard Response Spectrum of relatively higher frequencies. The result implles that the characteristics of the seismic strong ground motion, which may represent the domestic seismotectonic characteristics differ from of standard Response Spectrum, especillay of higher frequencies.

  • PDF

Measures for Improving Response of Autonomous Police Against Mass Disasters (자치경찰의 대형재난 대응 개선방안)

  • Jae-Min Lee;Jae-Hun Shin
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.481-489
    • /
    • 2023
  • Purpose: The purpose of this study is to examine the actual disaster response and suggest improvement measures for introduction of an autonomous police system Method: This study suggests the improvement measures by reviewing police disaster response manual, related statistical data, and statutes comprehensively Result: The introduction of autonomous police system enabled effective management of police based on circumstances of each region. However, there are still doubts on police response against situations that require large number of personnel. According to analysis on roles of autonomous police during the mass disasters, the autonomous police controlled disaster site to prevent secondary damage, prevented additional disaster damages, and rescued people. However, it is hard for the autonomous police to respond against the mass disasters due to its structure. Conclusion: To improve the response of autonomous police against mass disasters, this study suggested on disaster scene control and secondary damage prevention by the police, cooperative disaster response with regional autonomous police, and utilization of control tower.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Wilshire Grand: Outrigger Designs and Details for a Highly Seismic Site

  • Joseph, Leonard M.;Gulec, C. Kerem;Schwaiger, Justin M.
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • The 1100 foot [335 m] tall Wilshire Grand Center tower under construction in Los Angeles illustrates many key outrigger issues. The tower has a long, narrow floor plan and slender central core. Outrigger braces at three groups of levels in the tower help provide for occupant comfort during windy conditions as well as safety during earthquakes. Because outrigger systems are outside the scope of prescriptive code provisions, Performance Based Design (PBD) using Nonlinear Response History Analysis (NRHA) demonstrated acceptability to the Los Angeles building department and its peer review panel. Buckling Restrained Brace (BRB) diagonals are used at all outrigger levels to provide stable cyclic nonlinear behavior and to limit forces generated at columns, connections and core walls. Each diagonal at the lowest set of outriggers includes four individual BRBs to provide exceptional capacities. The middle outriggers have an unusual 'X-braced Vierendeel' configuration to provide clear hotel corridors. The top outriggers are pre-loaded by jacks to address long-term differential shortening between the concrete core and concrete-filled steel perimeter box columns. The outrigger connection details are complex in order to handle large forces and deformations, but were developed with contractor input to enable practical construction.