• 제목/요약/키워드: Sinusoidal output currents

검색결과 31건 처리시간 0.026초

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

교류-교류 행렬변환기를 이용한 유도전동기의 벡터제어 구현 (Implementation of Vector control for induction motor using the AC-AC matrix converter)

  • 김우현
    • 한국산업융합학회 논문집
    • /
    • 제6권1호
    • /
    • pp.3-10
    • /
    • 2003
  • Application of matrix converter to vector control of induction motor using simplified Venturini algorithm which is capable of achieving the maximum output voltage is developed. This algorithm simplifies the control algorithm and therefor reduces the digital implementation time. Matrix converter is used as voltage-referenced voltage fed vector controlled induction motor drive. This paper describes the performance of vector controlled induction motor with four quadrant capability employing a matrix converter power circuit. The advantage of this system over the conventional rectifier-inverter arrangement are capability for regeneration into the utility, sinusoidal supply currents and minimum passive components. The steady-state and transient performance of the induction motor drive under the vector control technique is demonstrate with simulation and experiment results.

  • PDF

CDM 램프의 안정적인 점등을 위한 새로운 구동기법 (A New Driving Method for the Stable Lighting of CDM Lamps)

  • 김민조;연재을;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.950-951
    • /
    • 2006
  • This paper proposed a new driving method for the stable lighting of CDM lamps. To avoid the acoustic resonance in the proposed method, the inverter output voltage will be a low frequency rectangular waveform containing a sinusoidal voltage ripple with high frequency. Moreover, the realtime power control of the inverter can be achieved by the control of switching currents. To verify the validity of tile proposed method, a prototype set-up was build and the experimental results are presented in this paper.

  • PDF

Design and Implementation of a Reverse Matrix Converter for Permanent Magnet Synchronous Motor Drives

  • Lee, Eunsil;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2297-2306
    • /
    • 2015
  • This paper presents the development of a system with a reverse matrix converter (RMC) for permanent magnet synchronous motor (PMSM) drive and its effective control method. The voltage transfer ratio of the general matrix converter is restricted to a maximum value of 0.866, which is not suitable for applications whose source voltages are lower than the load voltages. The proposed RMC topology can step up the voltage without any additional components in the conventional circuit. Its control method is different from traditional matrix converter’s one, thus this paper proposes control schemes of RMC by means of controlling both the generator and motor side currents with properly designed control loop. The converter can have sinusoidal input/output current waveforms in steady state condition as well as a boosted voltage. In this paper, a hardware system with an RMC for a PMSM drive system is described. The performance of the system was investigated through experiments

Z-소스 인버터의 병렬운전 특성 개선 (A Characteristic Improvement for the Parallel Operation of Z-source Inverters)

  • 김윤호;이욱영;서강문
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.56-61
    • /
    • 2007
  • 본 논문에서는 연료전지 시스템을 위한 Z-소스 인버터로 구성된 병렬운전 연료전지 시스템의 순환전류 감쇄 방안을 검토하였다. PWM 방식으로는 Carrier phase shifted SPWM을 적용하였으며, 이 방식은 출력 전류의 고조파 성분을 줄일 수 있는 장점을 갖는다. 그러나 이 기법을 Z-소스 인버터로 구성된 병렬운전 시스템에 적용하는 경우 추가적으로 순환전류가 발생한다. Z-소스 인버터로 구성된 병렬운전 시스템이 동작 시 발생하는 순환전류를 감소시키며, 부하전류에 낮은 고조파 성분을 가질 수 있도록 커플링된 순환전류 리액터를 사용하였다. 순환전류 리액터를 상호 커플링시킴으로써 순환전류를 추가적으로 감소시킬 수 있다. 이에 대한 적합성을 시뮬레이션과 실험을 통해 입증하였다.

연료 전지 시스템을 위한 Z-소스 인버터고 구성된 병렬 운전 시스템 (Parallel Operation Systems of Z-Source Inverters for Fuel Cell Systems)

  • 문현욱;정은진;김윤호
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.443-449
    • /
    • 2005
  • 본 논문에서는 연료 전지 시스템을 위한 Z-소스 인버터로 구성된 병렬 운전 시스템을 제시 하였다. PWM 방식으로는 Carrier phase shifted SPWM을 적용하였으며 이 방식은 출력 전류의 고조파 성분을 줄일 수 있는 장점을 갖는다. 그러나 이 기법을 Z-소스 인버터로 구성된 병렬 운전 시스템에 적용하는 경우 추가적으로 순환 전류를 발생한다. Z-소스 인버터로 구성된 병렬 운전 시스템이 동작 시 발생하는 순환 전류를 분석하고 순환 전류를 감소시키며, 부하전류에 낮은 고조파 성분을 가질 수 있도록 순환 전류 리액터를 사용하였다. 이에 대한 적합성을 시뮬레이션과 실험을 통해 입증하였다.

Torque Predictive Control for Permanent Magnet Synchronous Motor Drives Using Indirect Matrix Converter

  • Bak, Yeongsu;Jang, Yun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1536-1543
    • /
    • 2019
  • This paper presents an improved torque predictive control (TPC) for permanent magnet synchronous motors (PMSMs) using an indirect matrix converter (IMC). The IMC has characteristics such as a high power density and sinusoidal waveforms of the input-output currents. Additionally, this configuration does not have any DC-link capacitors. Due to these advantages of the IMC, it is used in various application field such as electric vehicles and railway cars. Recently, research on various torque control methods for PMSM drives using an IMC is being actively pursued. In this paper, an improved TPC method for PMSM drives using an IMC is proposed. In the improved TPC method, the magnitudes of the voltage vectors applied to control the torque and flux of the PMSM are adjusted depending on the PMSM torque control such as the steady state and transient response. Therefore, it is able to reduce the ripples of the output current and torque in the low-speed and high-speed load ranges. Additionally, the improved TPC can improve the dynamic torque response when compared with the conventional TPC. The effectiveness of the improved TPC method is verified by experimental results.

Carrier Phase-Shift PWM to Reduce Common-Mode Voltage for Three-Level T-Type NPC Inverters

  • Nguyen, Tuyen D.;Phan, Dzung Quoc;Dao, Dat Ngoc;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1197-1207
    • /
    • 2014
  • Common-mode voltage (CMV) causes overvoltage stress to winding insulation and damages AC motors. CMV with high dv/dt causes leakage currents, which create noise problems for equipment installed near the converter. This study proposes a new pulse-width modulation (PWM) strategy for three-level T-type NPC inverters. This strategy substantially eliminates CMV. The principle for selecting suitable triangle carrier signals for the three-level T-type NPC is described. The proposed method can mitigate the peak value of CMV by 50% compared with the phase disposition pulse-width modulation method. Furthermore, the proposed method exhibits better harmonic spectrum and lower root mean square value for the CMV than those of the reduced-CMV method on the basis of the phase opposition disposition PWM scheme with modulation index higher than 0.5. The proposed modulation can easily be implemented using software without any additional hardware modifications. Both simulation and experimental results demonstrate that the proposed carrier phase-shift PWM method has good output waveform performance and reduces CMV.

캐리어를 이용한 매트릭스 컨버터의 전압 변조 방법 (Carrier-based Modulation Method for Matrix Converter)

  • 윤영두;설승기
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.543-549
    • /
    • 2005
  • 본 논문에서는 캐리어(Carrier)를 이용한 매트릭스 컨버터(Matrix Converter)의 전압 변조 방법을 제안한다. 출력상전압에 적절한 옵셋(Offset) 전압을 더하고, 캐리어 파형의 기울기를 적절히 제어함으로써 입력 전류를 역율 1의 정현파로 제어하면서 동시에 출력 전압의 합성이 가능하다. 이 방법은 기존의 매트릭스 컨버터 전압 변조 방법인 SVPWM과 동일한 스위칭 패턴을 나타내지만, 그 구현은 훨씬 간단한다. 또한 기존의 전압형 인버터(Voltage Source Inverter, VSI)에서 발전된 2상/3상 변조, 과변조(Over Modulation) 등의 개념을 유사하게 적용할 수 있어 그 활용도가 매우 논다. Matlab/Simulink를 이용한 시뮬레이션 결과와 실험을 통해 제안된 방법의 타당성을 검증하였다.