• 제목/요약/키워드: Sinusoidal output

검색결과 345건 처리시간 0.03초

Effects of Imperfect Sinusoidal Input Currents on the Performance of a Boost PFC Pre-Regulator

  • Cheung, Martin K.H.;Chow, Martin H.L.;Lai, Y.M.;Loo, K.H.
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.689-698
    • /
    • 2012
  • This paper investigates the effects of applying different input current waveshapes on the performance of a continuous-conduction-mode (CCM) power-factor-correction (PFC) boost pre-regulator. It is found that the output voltage ripple of the pre-regulator can be reduced if the input current is modified to include controlled amount of higher order harmonics. This finding allows us to balance the performance of output regulation and the harmonic current emission when coming to the design of the pre-regulator. An experimental PFC boost pre-regulator prototype is constructed to verify the analysis and show the benefit of the pre-regulator operating with input current containing higher order harmonics.

직류전력 회생시스템의 역률개선에 관한 연구 (A Study on the Power Factor Improvement of DC Power Regenerating Systems)

  • 윤인식;서영민;홍순찬;윤덕용;한성수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.552-555
    • /
    • 2001
  • This paper deal with the power factor improvement of DC power regenerating systems, which are composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the inverter system are not sinusoidal. Regenerated complex power is analyzed on the basis of fundamental components and therefore the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero for nonsinusoidal case. Computer simulations are carried out to verify the validity of the proposed control scheme.

  • PDF

가상자속관측기를 이용한 3상 AC/DC PWM PFC 컨버터의 입력전압 센서리스 제어 개선 (Improved Input Voltage Sensorless Control of Three-Phase AC/DC PWM PFC Converter using Virtual Flux Observer)

  • 김영삼;소상호
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.566-574
    • /
    • 2013
  • In this paper, direct power control system for three-phase PFC AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the reduced-order virtual flux observer using the actual currents and the command control voltage. Moreover, source voltage sensors are replaced by a estimated flux. DC output voltage has been compensated by DC output ripple voltage estimation algorithm. The active and reactive powers estimation are performed based on the estimated flux and Phase angle. The proposed algorithm is verified through simulation and experiment.

An Enhanced Harmonic Voltage Compensator for General Loads in Stand-alone Distributed Generation Systems

  • Trinh, Quoc-Nam;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1070-1079
    • /
    • 2013
  • This paper develops an enhanced harmonic voltage compensator which is implemented with the aid of two repetitive controllers (RCs) in order to improve the output voltage performance of stand-alone distributed generation (DG) systems. The proposed harmonic voltage compensator is able to maintain the DG output voltage sinusoidal regardless of the use of nonlinear and/or unbalanced loads in the load side. In addition, it can offer good steady-state performance under various types of loads and a very fast dynamic response under load variations to overcome the slow dynamic response issue of the traditional RC. The feasibility of the proposed control strategy is verified through simulations and experiments.

대용량 인버터의 병렬운전 (Parallel Operation of High Power Inverters)

  • 이현동;지준근;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.150-152
    • /
    • 1994
  • This paper deals with the parallel operation of inverters. To enlarge capacity of inverter system and reduce current ripples on inverter output side, two or more inverters are operated in parallel. Up to now six-step inverters and sinusoidal PWM inverters are considered in parallel operation, but using space-vector PWM inverters we can get many advantages of reducing ripple current energy and torque ripple and so on. As we can choose effective voltage vectors more freely than single operation, inverter output current ripples can be reduced by shifting beginning and end point of switching state back and forth.

  • PDF

UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구 (Control Strategy of Resonant DC Link Inverter for UPS)

  • 백주원;유동욱;민병권;류승표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

유전체 장벽 방전을 위한 양방향 펄스 전원장치 (Bidirectional Pulse Power Supply for Dielectric Barrier Discharge)

  • 신완호;홍원석;정환명;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1521-1523
    • /
    • 2005
  • High voltage plasma power supply was adopted to control polluted gases and an ozone generation. Bidirectional pulse power supply consisted of power semiconductor switch devices, a high voltage transformer, and a control board adapted switching method. Plasma power supply with sinusoidal bidirectional pulse, which has output voltage range of 0-20kV and output frequency range of 1kHz-20kHz, is realized. Using proposed system, pulsed high voltage/high frequency discharges were tested in a DBD(dielectric barrier discharge) reactor, and the spatial distribution of a glow discharge was observed. The system showed stable operational characteristics, even though the voltage and the frequency increased. Above features were verified by experiments.

  • PDF

3개의 양방향 벅-부스트 컨버터를 이용한 3상 인버터 시스템 (Three Phase Inverter System Utilizing Three Bi-directional Buck-Boost Converter)

  • 김성영;남광희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.551-554
    • /
    • 2006
  • An inverter system which consists of three bi-directional buck-boost converters, is proposed for motor driving. Three phase sinusoidal output voltages can be generated by utilizing three buck-boost converters. The advantage of this scheme is that it does not require a separate DC-DC converter for motor driving, i.e. inverter function is combined into the three DC-DC converters. This topology is suitable for inverters for hybrid or fuel cell vehicles where DC link voltage is subject to change depending upon charging status or output power. So the proposed system is capable of driving motor at high speed. The converter system is controlled by PI controller and simulation results done by MATLAB SIMULINK are provided.Ҙ?⨀ሉȀ̀㘰々K䍄乍?ጊ츀Ѐ㔹〻Ԁ䭃䑎䴀

  • PDF

Electrochemical Frequency Modulation: Solution Resistance and Double Layer Capacitance Considerations

  • Lalvani, Shashi;Ullah, Sifat;Kerr, Lei
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.231-241
    • /
    • 2021
  • The objective of this study was to evaluate total current under steady-state conditions for a material undergoing corrosion using the electrochemical frequency modulation (EFM) technique, taking into account the presence of solution resistance and double layer capacitance. The analysis involving linearization of the Tafel curve allowed for the estimation of corrosion parameters. Results showed that the output signal was dependent on fundamental frequencies and their multiples. In addition, the output signal almost manifested itself at frequencies that were sums of fundamental frequencies of the applied sinusoidal signal. The harmonics calculated showed a significant shift from the principal frequency of input signals. The investigation involved the influence of corrosion current and anode-to-cathode Tafel slope ratio on faradaic and non-faradaic currents (including the average and RMS). The model presented showed both qualitative and quantitative improvements over the previously developed EFM technique that ignored the influence of solution resistance and the double layer capacitance while assuming the applied DC potential corresponded to the corrosion potential of the corroding material.

비선형 시스템규명; 신경회로망과 기존방법의 비교 (Nonlinear System Identification; Comparison of the Traditional and the Neural Networks Approaches)

  • 정길도
    • 한국정밀공학회지
    • /
    • 제12권5호
    • /
    • pp.157-165
    • /
    • 1995
  • In this paper the comparison between the neural networks and traditional approaches as nonlinear system identification methods are considered. Two model structures of neural networks are the state space model and the input output model neural networks. The traditional methods are the AutoRegressive eXogeneous Input model and the Nonlinear AutoRegressive eXogeneous Input model. Computer simulation for an analytic dynamic model of a single input single output nonlinear system has been done for all the chosen models. Model validation for the obtained models also has been done with testing inputs of the sinusoidal, ramp and the noise ramp.

  • PDF