• Title/Summary/Keyword: Sinusoidal input

Search Result 388, Processing Time 0.036 seconds

CONTROL CHARACTERISTICS OF SINGLE-SWITCH, THREE-PHASE BUCK RECTIFIERS

  • Song, Joong-Ho;Kim, Yong-Duck;Lee, Dong-Yun;Choy, Ick;Choi, Joo-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.658-662
    • /
    • 1998
  • A pulse frequency modulation control method for single-switch three-phase buck rectifiers is comprehensively studied in this paper. The proposed pulse frequency control method leads the three-phase buck rectifier to high performance system that can draw the nearly sinusoidal imput-line currents. The simulated and experimental results demonstrate that the system provides low total harmonic distortion of the input-line currents, high-power factor, and good output voltage regulation.

  • PDF

Transformer-less CCFL Driver for LCD Backlight (LCD 백라이트용 트랜스포머 없는 냉음극관(CCFL) 구동 회로)

  • Choi Eun-Seok;Yoon Hyun-Ki;Moon Gun-Woo;Youn Myung-Joong;Kang Moon-Shik
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.81-83
    • /
    • 2006
  • The conventional cold cathode fluorescent lamp (CCFL) driver for LCD TV has a transformer for each lamp to step up the high sinusoidal waveform from the low input voltage. The transformer used in the conventional topology causes the driver to have bulky size and high cost. This paper proposes a new transformer-less CCFL driver for LCD backlight that is based on the parallel-loaded resonant inverter topology. This resonant topology enables the circuit to supply enough high voltage for CCFL without a transformer. Also, with current-balancing technique, this transformer-less inverter drives 16 CCFL lamps.

  • PDF

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

Single-Stage Power Factor Corrected Converter for SRM Drive (단상 SRM 구동을 위한 1단 방식 역률보상형 컨버터)

  • Lee Jung-Han;Park Sung-Jun;Park Han-Woong;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.502-505
    • /
    • 2002
  • A singl-phase power factor corrected converter for switched reluctance motor driving is presented to achieve sinusoidal, near unity power factor input currents. Because it combines a power factor corrected converter and a conventional asymmetric SRM driver Into one power stage, the configuration has a simple structure resulted in low cost. A prototype to drive 6/6 poles SRM employing a parking magnet is designed to evaluate the proposed topology The characteristics and operational mode will be discussed in depth, and the validity of proposed driver will be verified through the experimental results.

  • PDF

Harmonic Reduction of Parallel-Connected Thyristor Rectifiers with an Active Interphase Reactor

  • Choi, Sewan;Oh, Junyong;Kim, Kiyong
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.276-280
    • /
    • 1998
  • This paper proposes a harmonic a harmonic reduction technique of the parallel-connected twelve-pulse thyristor rectifiers. The proposed system is an improvement over the diode rectifier system with an active interphase reactor [2]. In this scheme, a low KVA (0.15 Po (PU) ) active current source injects a triangular current into an interphase reactor of a twelve-pulse thyristor rectifier along the phase delay angle. The current injection results in near sinusoidal input current with less than 1% THD. Detailed analysis of the proposed scheme along scheme along with design equations is illustrated. Simulation results verify the concept.

  • PDF

Analysis, Design and Implementation of an Interleaved Single-Stage AC/DC ZVS Converters

  • Lin, Bor-Ren;Huang, Shih-Chuan
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.258-267
    • /
    • 2012
  • An interleaved single-stage AC/DC converter with a boost converter and an asymmetrical half-bridge topology is presented to achieve power factor correction, zero voltage switching (ZVS) and load voltage regulation. Asymmetric pulse-width modulation (PWM) is adopted to achieve ZVS turn-on for all of the switches and to increase circuit efficiency. Two ZVS half-bridge converters with interleaved PWM are connected in parallel to reduce the ripple current at input and output sides, to control the output voltage at a desired value and to achieve load current sharing. A center-tapped rectifier is adopted at the secondary side of the transformers to achieve full-wave rectification. The boost converter is operated in discontinuous conduction mode (DCM) to automatically draw a sinusoidal line current from an AC source with a high power factor and a low current distortion. Finally, a 240W converter with the proposed topology has been implemented to verify the performance and feasibility of the proposed converter.

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

Swing-up control of the 2-link rotational pendulum (2축 회전진자의 스윙업제어)

  • 양동훈;유기정;고영길;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.371-371
    • /
    • 2000
  • A strategy for the swing-up control according to states of the 2-link rotational pendulum is proposed. The proposed controller consists of two modes of control such as divergence mode and stabilization mode. When the controller is in divergence mode, control input is generated using sinusoidal and signum function to make the first and second links reach the bottom and top positions, respectively. After the controller finishes divergence mode, stabilization mode is initiated to keep the pendulum around the top position using pole-placement method. Dynamic models including actuator dynamics are obtained using coordinate changes at each control mode. Simulation results are given to show the effectiveness of the proposed method.

  • PDF

An Emphirical Closed Loop Modeling of a Suspension System using a Neural Networks (신경회로망을 이용한 폐회로 현가장치의 시스템 모델링)

  • 김일영;정길도;노태수;홍동표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.384-388
    • /
    • 1996
  • The closed-loop system modeling of an Active/semiactive suspension system has been accomplished through an artificial neural Networks. The 7DOF full model as the system equation of motion has been derived and the output feedback linear quadratic regulator has been designed for the control purpose. For the neural networks training set of a sample data has been obtained through the computer simulation. A 7DOF full model with LQR controller simulated under the several road conditions such as sinusoidal bumps and the rectangular bumps. A general multilayer perceptron neural network is used for the dynamic modeling and the target outputs are feedback to the input layer. The Backpropagation method is used as the training algorithm. The modeling of system and the model validation have been shown through computer simulations.

  • PDF

Finite Element Method using Complex Harmonics for analyzing saturation characteristics (포화 특성 해석을 위한 복소 고조파 유한 요소해석법)

  • Chung, Yong-Seek;Park, Gwan-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.11-14
    • /
    • 1990
  • The Complex Harmonic Balance Finite Element Method CHBFEM ) is dicussed for the time - periodic magnetic field with saturation characteristics. And Jw - method which is used for analyzing liner system with sinusoidal voltage input can be generalized in nonlinear time-periodic magnetio field system. The CHBFEM enables us to calculate the each harmonic magnetic flux ditribution and the distortion of currents resulting from material at an AC voltage source and to save calculating time, the number of calculation and computer memory.

  • PDF