• 제목/요약/키워드: Sink

Search Result 1,736, Processing Time 0.025 seconds

A Study on the Flow and Cooling Characteristics with the Inlet Blockage of a Fan-Sink (홴싱크의 입구 봉쇄에 따른 유동 및 냉각 특성에 관한 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Yun, Jae-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.83-88
    • /
    • 2004
  • In this study, the flow and thermal performance of the heat sink and fan-sink were experimentally studied to predict the operating condition of the fan-sink. The experiments of the flow and thermal resistance of the heat sink with various inlet blockage, which were occurred by the shapes of the axial fans, were conducted for the proof of the effects of the inlet blockages. The greater the inlet blockage of the heat sink, the higher the pressure drop and lower the thermal resistance of the heat sink will be. The operating point of the fan-sink was predicted by the pressure drop curve with the inlet blockage, which was corresponded to the selected fan and the fan performance curve, and verified by the performance test of the fan-sink. The predicted operating point of the fan-sink had good agreement with the result of the performance test of the fan-sink within $0.7\%$ of the volume flow rates. Measured thermal resistance of the fan-sink was equivalent to that of the heat sink with the same inlet blockage of the fan-sink. It was shown that the heat transfer characteristics of the heat sink were influenced by the flow interaction between the selected fan and the heat sink. To improve the thermal resistance of the heat sink, it is necessary to consider appropriate flow patterns of the fan outlet entering into the heat sink.

  • PDF

An Experimental Study on the Thermal Resistance Characteristics for Various Types of Heat Sinks (다양한 형상의 Heat Sink 열저항 특성에 관한 실험적 연구)

  • 김종하;윤재호;이창식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.676-682
    • /
    • 2002
  • This paper has been made to investigate the thermal performance characteristics for the several types of heat sinks such as extruded heat sink, aluminum foam heat sink, layered heat sink. The various types heat sinks are prepared and tested for natural convection as well as forced convection. The experimental results for natural convection are compared to those for three types of heat sink so that the appropriate heat sink can be designed or chosen according to the heating conditions. The overall heat transfer performances for layered heat sink, extruded heat sink and aluminum foam heat sink are almost comparable to those under natural convection and forced convection. The forced convection of layered heat sink become 1.2 times as high as those of extruded heat sink, and the forced convection of extruded heat sink become 1.2 times as high as those of aluminum foam heat sink. This study shows that bar height, bar distance and number of bar for layered heat sink are important parameters, which have a serious influence on thermal performance for layered heat sinks.

Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink (팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구)

  • Lee Kyoung-Yong;Choi Young-Seok;Yun Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

Dual Sink Nodes for Sink Node Failure in Wireless Sensor Networks (무선 센서 네트워크에서의 싱크노드 실패에 대비한 이중 싱크노드 장치)

  • Kim, Dae-Il;Park, Lae-Jeong;Park, Sung-Wook;Lee, Hyung-Bong;Moon, Jung-Ho;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.6
    • /
    • pp.369-376
    • /
    • 2011
  • Since wireless sensor networks generally have the capability of network recovery, malfunction of a few sensor nodes in a sensor network does not cause a crucial problem paralyzing the sensor network. The malfunction of the sink node, however, is critical. If the sink node of a sensor network stops working, the data collected by sensor nodes cannot be delivered to the gateway because no other sensor nodes can take the place of the sink node. This paper proposes a TDMA-based wireless sensor network equipped with dual sink nodes, with a view to preventing data loss in the case of malfunction of a sink node. A secondary sink node, which synchronizes with a primary sink node and receives data from other sensor nodes in normal situations, takes the role of the primary sink node in the case of malfunction of the primary sink, thereby eliminating the possibility of data loss. The effectiveness of the proposed scheme is demonstrated through experiments.

Heritability Estimates of Sink and Source Characters by $F_2$ and $F_5$ Correlation in Rice ($F_2$$F_5$ 상관에 의한 벼 Sink 및 Source 관련형질의 유전력 추정)

  • Ha, Woon-Goo;Kim, Ho-Yeong;Choi, Hae-Chune;Lim, Sang-Jong;Suh, Hak-Soo;Lim, Moo-Sang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.3
    • /
    • pp.151-156
    • /
    • 2002
  • The heritability of sink-source characters was estimated by regression coefficient between F$_2$ and F$_{5}$ in two crosses of IR 66738-118-1-2/Gayabyeo and the Ilpumbyeo/YR 15965 Acp 33. In order to get the some basic information for breeding of high yielding rice, genetic resources of new plant type with low tiller and heavy panicle were used. Most of the sink and source characters in Ilpumbyeo/YR 15965 Acp 33 cross showed high heritability over than 0.224. But the specific leaf area and sink-source ratio displayed low heritability being 0.009 and 0.013, respectively. Heritability of all sink and source characters in IR 66738-118-1-2/Gayabyeo cross ranged from 0.115 to 0.247. Correlation coefficient between yield and yield components in both combination were in the ranged between 0.001 and 0.247. But correlations among the yield components were not significant. Correlations between the yield and sink-source characters in both combinations were also highly significant. Particularly, correlation between the grain tiling ratio and most of the sink-source characters in IR 66738-118-1-2/Gayabyeo cross were not significant. In Ilpumbyeo/YR 15965 Acp 33 cross, correlations between grain filling ratio and source characters were positively significant. but sink characters (sink capacity and sink-source ratio, etc) were negatively significant.

Development and Characterization of Optimum Heat Sink for 30 W Chip on Board LED Down-Light

  • Seo, Bum-Sik;Lee, Ki-Joung;Yang, Jong-Kyung;Cho, Young Seek;Park, Dae-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.292-296
    • /
    • 2012
  • An optimum heat sink for a 30 W chip on board (COB) LED down-light is designed, fabricated, and characterized. By using the SolidWorks Flow simulator and thermal analysis software, the thermal characteristics of the optimum heat sink is analyzed. Four different types of heat sink are simulated and an optimum structure of the heat sink is found. The simulated temperature of the heat sink when operating the LED down-light is $55.9^{\circ}C$, which is only a difference of $2^{\circ}C$ from the measured temperature. In order to reduce the temperature further, a copper spreader is introduced to the heat sink. The temperature of the heat sink with the copper spreader is $3^{\circ}C$ lower than without the copper spreader.

A Grid-based Efficient Routing Protocol for a Mobile Sink in Wireless Sensor Networks

  • Lee, Taekkyeun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.2
    • /
    • pp.35-43
    • /
    • 2018
  • In this paper, we propose a grid-based efficient routing protocol for a mobile sink in wireless sensor networks. In the proposed protocol, the network is partitioned into grids and each grid has a grid head. For the efficient routing to a mobile sink, the proposed protocol uses a mobile sink representative node to send the data to a mobile sink and grid heads are used as a mobile sink representative node. Furthermore, the proposed protocol uses nodes in the boundary of the center grid as position storage nodes. The position storage nodes store the position of a mobile sink representative node and provide source nodes with it for data delivery. With these features, the proposed protocol can reduce a lot of overhead to update the position information and improve the delay of data delivery to a mobile sink. The proposed protocol performs better than other protocols in terms of the delay and the energy consumption per node in the performance evaluation.

EEDARS: An Energy-Efficient Dual-Sink Algorithm with Role Switching Mechanism for Event-Driven Wireless Sensor Networks

  • Eslaminejad, Mohammadreza;Razak, Shukor Abd;Ismail, Abdul Samad Haji
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2473-2492
    • /
    • 2012
  • Energy conservation is a vital issue in wireless sensor networks. Recently, employing mobile sinks for data gathering become a pervasive trend to deal with this problem. The sink can follow stochastic or pre-defined paths; however the controlled mobility pattern nowadays is taken more into consideration. In this method, the sink moves across the network autonomously and changes its position based on the energy factors. Although the sink mobility would reduce nodes' energy consumption and enhance the network lifetime, the overhead caused by topological changes could waste unnecessary power through the sensor field. In this paper, we proposed EEDARS, an energy-efficient dual-sink algorithm with role switching mechanism which utilizes both static and mobile sinks. The static sink is engaged to avoid any periodic flooding for sink localization, while the mobile sink adaptively moves towards the event region for data collection. Furthermore, a role switching mechanism is applied to the protocol in order to send the nearest sink to the recent event area, hence shorten the path. This algorithm could be employed in event-driven and multi-hop scenarios. Analytical model and extensive simulation results for EEDARS demonstrate a significant improvement on the network metrics especially the lifetime, the load and the end-to-end delay.

Cluster-Based Mobile Sink Location Management Scheme for Solar-Powered Wireless Sensor Networks

  • Oh, Eomji;Kang, Minjae;Yoon, Ikjune;Noh, Dong Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.33-40
    • /
    • 2017
  • In this paper, we propose a sink-location management and data-routing scheme to effectively support the mobile sink in solar-powered WSN. Battery-based wireless sensor networks (WSNs) have a limited lifetime due to their limited energy, but solar energy-based WSNs can be supplied with energy periodically and can operate forever. On the other hand, introduction of mobile sink in WSNs can solve some energy unbalance problem between sink-neighboring nodes and outer nodes which is one of the major challenges in WSNs. However, there is a problem that additional energy should be consumed to notify each sensor node of the location of the randomly moving mobile sink. In the proposed scheme, one of the nodes that harvests enough energy in each cluster are selected as the cluster head, and the location information of the mobile sink is shared only among the cluster heads, thereby reducing the location management overhead. In addition, the overhead for setting the routing path can be removed by transferring data in the opposite direction to the path where the sink-position information is transferred among the heads. Lastly, the access node is introduced to transmit data to the sink more reliably when the sink moves frequently.

A Design of a Selective Multi Sink GRAdient Broadcast Scheme in Large Scale Wireless Sensor Network (대규모 무선 센서 네트워크 환경을 위한 다중 Sink 브로드캐스팅 기법 설계)

  • Lee, Ho-Sun;Cho, Ik-Lae;Lee, Kyoon-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.239-248
    • /
    • 2005
  • The reliability and efficiency of network must be considered in the large scale wireless sensor networks. Broadcast method must be used rather than unicast method to enhance the reliability of networks. In recently proposed GRAB (GRAdient Broadcast) can certainly enhance reliability of networks fy using broadcast but its efficiency regarding using energy of network is low due to using only one sink. Hence, the lifetime of networks is reduced. In the paper we propose the scheme of SMSGB (Selective Multi Sink Gradient Broadcast) which uses single sink of multi-sink networks. The broadcast based SMSGB can secure reliability of large scale wireless sensor networks. The SMSGB can also use the network's energy evenly via multi sink distribution. Our experiments show that using SMSGB was reliable as GRAB and it increased the network's lifetime by 18% than using GRAB.

  • PDF