• 제목/요약/키워드: Single-strand tendon

검색결과 5건 처리시간 0.028초

Single -portal Subscapualrs tendon repair

  • 최창혁;김신근;장호진;채성범
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2008년도 제16차 학술대회
    • /
    • pp.179-179
    • /
    • 2008
  • For a partial tear of the subscapularis tendon, the presenting technique requires only the anterior portal for preparing the footprint and suture management, as well as the subclavian portal for placing the suture anchor and suture hook without inserting a cannula. It provides both a good angle for anchor placement and sufficient space for managing the upper portion of a subscapularis tendon tear. A spinal needle was inserted through the subclavian portal in order to identify the appropriate angle for placing the suture anchor. A 3-mm incision was made for the subclavian portal and a biosuture anchor was placed on the footprint portion of the subscapularis tendon. In order to avoid crowding, each limb of both strands of the biosuture anchor were passed through the tendon- posteromedial side first, and anterolateral side second, using a switching technique with suture hook embedded with no.1 PDS. A suture tie was applied in a reverse sequence (the lateral strand first and the medial strand second) through the anterior cannula using a sliding technique.

  • PDF

비부착식 단일 강연선용 원형 정착구의 일방향 슬래브 적용에 관한 실험적 연구 (An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon)

  • 김민숙;노경민;이영학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.45-51
    • /
    • 2019
  • In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.

반건양건 단일 4가닥을 이용한 전방십자인대 재건술 (Anterior Cruciate Ligament Reconstruction with a Four-Strand Single Semitendinosus Tendon Autograft)

  • 경희수;김태공;오창욱;윤상협
    • 대한관절경학회지
    • /
    • 제13권2호
    • /
    • pp.138-142
    • /
    • 2009
  • 목적: 반건양건과 박건을 모두 채취함으로써 야기되는 공여부 이환을 줄이기 위하여 반건양건 단일 4가닥 건을 이용한 전방십자인대 재건술을 시행하여 결과를 보고한다. 대상 및 방법: 반건양건 단일 4가닥 건을 사용한 전방십자인대 재건술을 37명의 환자에게 시행하였다. 평균 나이는 28.6세였고, 남자 34명, 여자 3명이었다. 수상으로부터 수술까지의 기간은 5.4개월이었다. 동반 손상은 반월상 연골 손상 10예, 내측부인대 손상 3예, 골연골 손상 1예 있었다. 평균 추시는 16개월(12~18개월)이었고, 임상 평가는 관절 운동범위, Lachman 검사, pivot-shift 검사, Lysholm 점수, KT-2000 슬관절계를 이용하였다. 결과: 37명 모두 평균 150도로 정상측과 같은 슬관절 운동범위를 보였으며, 35예에서 Lachman 검사 및 pivot-shift 검사 상 음성이었다. Lysholm 점수는 84점에서 92점으로 개선되었다. 비협조적인 재활로 인하여 2예에서 슬관절의 이완이 남았으며, KT-2000 슬관절계를 이용하여 건측과 비교 측정한 평균 슬관절 전방 전위는 술 전 6.7 mm에서 최종 추시 시 2.1 mm로 개선되었다. 결론: 반건양건 단일 4가닥 건을 이용한 전방십자인대 재건술은 만족할 만한 임상적 결과를 보여 주었다.

  • PDF

Numerical study of mono-strand anchorage mechanism under service load

  • Marceau, D.;Fafard, M.;Bastien, J.
    • Structural Engineering and Mechanics
    • /
    • 제18권4호
    • /
    • pp.475-491
    • /
    • 2004
  • Anchorage devices play an important role in post-tensioned bridge structures since they must sustain heavy loads in order to permit the transfer of the prestressing force to the structure. In external prestressing, the situation is even more critical since the anchorage mechanisms, with the deviators, are the only links between the structure and the tendons throughout the service life of the structure. The behaviour of anchorage devise may be studied by using the finite element method. To do so, each component of the anchorage must be adequately represented in order to approximate the anchor mechanism as accurately as possible. In particular, the modelling of the jaw/tendon device may be carried out using the real geometry of these two components with an appropriate constitutive contact law or by replacing these components by a single equivalent. This paper presents the numerical study of a mono-strand anchorage device. The results of a comparison between two different representations of the jaw/tendon device, either as two distinct components or as a single equivalent, will be examined. In the double-component setup, the influence of the wedge configuration composing the jaw, and the influence of lubrication of the anchor, will be assessed.

자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 - (Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes)

  • 안진환;이상학;안형권;강홍제
    • 대한관절경학회지
    • /
    • 제9권2호
    • /
    • pp.222-231
    • /
    • 2005
  • 목적: 저자들은 5가닥의 자가 슬괵건을 이용하여 기존의 전내측 다발에 부가적인 후외측 다발을 통한 전방 십자인대 이중 다발 재건술을 소개하고자 한다. 수술 술기: 경골 터널은 기존의 단일 터널 방법을 사용하였고, 대퇴 터널은 전내측과 후외측 다발을 위한 이중 터널 방법을 사용하였다. 전내측 대퇴 터널은 최소한의 대퇴 과간 절흔 성형술 후 기존의 방법과 동일하게 11시 혹은 1시 방향에 대퇴과 절흔의 후방 경계(over-the-top)에서 후방 피질골이 1 mm 두께로 남아 있게 만든다. 또한 후 외측 대퇴 터널은 outside-in 방법을 사용하여 관절 내 터널 위치는 슬관절 90도 굴곡 상태에서 외측 반월상 연골 후각의 경골 부착부 내연(inner margin)에서 외측 대퇴과 내측벽의 상방 $5{\sim}7mm$ 부위에 4.5 mm reamer 이용하여 만들어 준다. 이중 다발을 위한 이식건으로 전내측 다발은 기존의 4가닥 슬괵건을 사용하고 후외측 다발은 반건양건 단일 가닥으로 만든다. 대퇴 터널 고정 방법으로 전내측 다발은 rigid fix system으로 고정하며 후외측 다발은 관절 밖에 miniplate를 이용하여 endobutton 방식으로 결찰로 고정한다. 이 후 경골 터널 고정은 슬관절을 $10{\sim}20$도 굴곡 상태에서 이중 다발을 함께 인장 강도를 주고 간섭 나사못으로 고정하고 post tie로 보강한다. 결론: 저자들은 비교적 우수한 결과를 보여주었던 기존의 전내측 다발에 회전 안정성을 위한 부가적인 후외측 다발을 통해 5가닥(경우에 따라 6가닥)의 자가 슬괵건을 이용한 이중 다발 재건술을 시행함으로써 좋은 결과가 기대된다.

  • PDF