• Title/Summary/Keyword: Single-stage

검색결과 2,445건 처리시간 0.119초

구치부 단일 임플란트의 생존율에 대한 후향적 연구 (A Retrospective Clinical Study of Survival Rate for a Single Implant in Posterior Teeth)

  • 한성일;이재훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권3호
    • /
    • pp.186-199
    • /
    • 2012
  • Purpose: Single implants, of which screw loosening has been observed frequently, presents problems such as fixtures fractures, marginal bone loss, and inflammation of the soft tissue around the implant. However, the single implant is more conservative, cost effective, and predictable compared to the 3 unit bridge with respect to the long-term outcome. This study evaluated the survival rate as well as future methods aimed at increasing the survival rate in single implants in posterior teeth. Methods: Among the implants placed in the Dankook University Dental Hospital department of Oral & Maxillofacial surgery from January 2001 to June 2008, 599 implants placed in the maxillar and mandibular posterior were evaluated retrospectively. Survival rates were investigated according to implant location, cause of tooth loss, gender, age, general disease, fixture diameter and length, surface texture, implant type and shape, presence of bone graft, surgery stage, surgeons, bone quality and opposite teeth. Results: Out of 599 single implants in posterior teeth, 580 implants survived and the survival rate was 96.8%. The difference in survival rate was statistically significant according to the implant location. The survival rate was low (84.2%) in implants exhibiting a wide diameter (${\geq}5.1mm$) and the surface treated by the acid etching group demonstrated a significantly lower survival rate (91.1%). One stage surgical procedure, which implemented a relatively better bone quality survival rate (100%), was higher than the two stage surgical procedure (96.1%). The survival rate of type IV bone quality (75%) was significantly lower than the other bone quality. Conclusion: Single posterior teeth implant treatments should use an improved surface finishing fixture as well as careful and safe procedures when performing implant surgery in the maxilla premolar and molar regions since bone quality is poor.

새로운 단일전력단 및 단일스위치 방식의 자기결합형 역률개선 컨버터 그룹 (New Group of Magnetic Coupled Power Factor Correction Converter with Single-Stage and Single-Switch)

  • 문건우;추진부;노정욱;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2240-2242
    • /
    • 1997
  • A new group of magnetic coupled high power factor converter with a single-switch /single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

A Simple ZVT PWM Single-Phase Rectifier with Reduced Conduction Loss and Unity Power Factor

  • Kim, In-Dong;Choi, Seong-Hun;Nho, Eui-Cheol;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.55-63
    • /
    • 2007
  • This paper proposes a simple unity power factor zero-voltage-transition (ZVT) pulse-width-modulated (PWM) single-phase rectifier, which features reduced switching and conduction losses. The switching loss reduction is achieved by a simple auxiliary commutation circuit, and the conduction loss reduction is achieved by employing a single-stage converter, rather than a typical double-stage converter comprising of a front-end rectifier and a boost rectifier. Furthermore, thanks to good features such as a simple PWM control at constant frequency, low switch stress, low Var rating of commutation circuits, and simple power circuit structure, it is suitable for high power applications. The principles of operation are explained in detail, and a major characteristics analysis and the experimental results of the new converter are also included in this paper.

3단계 공급사슬에서 다완제품의 통합재고모형에 관한 연구 (An Integrated Inventory Model for a Three-Layer Supply Chain with Multiple Items)

  • 김대홍
    • 산업경영시스템학회지
    • /
    • 제37권4호
    • /
    • pp.116-125
    • /
    • 2014
  • In this paper, we investigate an inventory and production system in a three-layer supply chain system involving a single supplier, single manufacturer and multiple retailers. Earlier study in this type of supply chain only consider a single raw material in order to produce single item, but we consider raw materials in order to produce multiple items. It is assumed that the cycle time at each stage is an integer multiple of the adjacent downstream stage. We develop an iterative solution procedure to find the order quantity for the multiple items and raw materials that minimizes the supply chain-wide total cost per unit time of the supplier and manufacturer's raw materials ordering and holding, setup and finished items holding, the retailer's ordering and inventory holding. Numerical examples are presented to show that the proposed heuristic gives good performance.

넓은 출력 전압제어범위를 갖는 3레벨 단상 단일전력단 AC/DC 컨버터 (THREE LEVEL SINGLE-PHASE SINGLE STAGE AC/DC RESONANT CONVERTER WITH A WIDE OUTPUT OPERATING VOLTAGE RANGE)

  • 마리우스;이강우;김민지;김은수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.434-435
    • /
    • 2018
  • In this paper, a single-phase single-stage three-level AC/DC converter with a wide controllable output voltage is presented. It integrates a PFC converter and a three level DC/DC converter into one. The proposed converter operates at a fixed frequency and provides a wide controllable output voltage ($200V_{dc}-430V_{dc}$) with high efficiencies over a wide load range. In addition, the input boost inductors operate in a discontinuous mode to improve the input power factor. Moreover, all the switching devices operate with ZVS, and the converter's THD is small especially at full load. The feasibility of the proposed converter is verified with experimental results of a 1.5kW prototype.

  • PDF

다단 왕복동 공기압축기의 평형추 설계 (Counter Weight Design of Multi-stage Reciprocating Air Compressors)

  • 김영철;김병옥;신현익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.656-661
    • /
    • 2003
  • Modem reciprocating air compressors have tendency to a multi-stage W-type or V-type cylinder arrangement for the purpose of high outlet pressure, compactness and low vibration and noise. A valid counter weight calculation method using the complex expression is proposed for reducing the inertia forces of the compressor. Counter weight removes only 1st forward whirl component. Counter weight formulations are applied to the six various compressor structures which are (a) 1 cylinder single-throw crank shaft, (b) 2 cylinder single-throw crank shaft (c) 2 cylinder double-throw clank shaft, (d) 3 cylinder single-throw crank shaft, (e) 4 cylinder single-throw crank shaft and (f) 4 cylinder double-throw crank shaft. The improvement of performance is verified through available vibration test.

  • PDF

Single-Stage Double-Buck Topologies with High Power Factor

  • Pires, Vitor Fernao;Silva, Jose Fernando
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.655-661
    • /
    • 2011
  • This paper presents two topologies for single-stage single-phase double-buck type PFC converters, designed to operate at high power factor, near sinusoidal input currents and adjustable output voltage. Unlike the known buck type PFC topologies, in which the output voltage is always lower than the maximum input voltage, the proposed converters can operate at output voltages higher than the ac input peak voltage. A reduced number of switches on the main path of the current are another characteristic of the two proposed topologies. To shape the input line currents, a fast and robust controller based on a sliding mode approach is proposed. This active non-linear control strategy, applied to these converters allows high quality input currents. A Proportional Integral (PI) controller is adopted to regulate the output voltage of the converters. This external voltage controller modulates the amplitude of the sinusoidal input current references. The performances of the presented rectifiers are verified with experimental results.

공급사슬 내의 재고관리를 위한 모의실험에 기초한 발견적 기법: 봉사척도 관점 (A Simulation-based Heuristic Algorithm for Determining a Periodic Order Policy at the Supply Chain: A Service Measure Perspective)

  • 박창규
    • 산업공학
    • /
    • 제13권3호
    • /
    • pp.424-430
    • /
    • 2000
  • Supply chain management (SCM) is an area that has recently received a great deal of attention in the business community. While SCM is relatively new, the idea of coordinated planning is not. During the last decades, many researchers have investigated multi-stage inventory problems. However, only a few papers address the problem of cost-optimal coordination of multi-stage inventory control with respect to service measures. Even published approaches have a shortcoming in dealing with a delivery lead time consisted of a shipping time and a waiting time. Assumed that there is no waiting time, or that the delivery lead time is implicitly compounded of a shipping time and a waiting time, the problem is often simplified into a multi-stage buffer allocation and a single-stage stochastic buffer sizing problem at all installations. This paper presents a simulation-based heuristic algorithm and a comparison with others for the problem that cannot be decomposed into a multi-stage buffer allocation and a single-stage stochastic buffer sizing problem because the waiting time ties together all stages. The comparison shows that the simulation-based heuristic algorithm performs better than other approaches in saving average inventory cost for both Poisson and Normal demands.

  • PDF

배터리 에너지 저장 장치를 위한 2단 DC-DC-AC 컨버터의 모델링 방법 (Modeling and Control of a Two-Stage DC-DC-AC Converter for Battery Energy Storage System)

  • 현동엽;정석언;현동석
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.422-430
    • /
    • 2014
  • This study proposes a small-signal model and control design for a two-stage DC-DC-AC converter to investigate its dynamic characteristics in relation to battery energy storage system. When the circuit analysis of the two-stage DC-DC-AC converter is attempted simultaneously, the mathematical procedure of deriving the dynamic equation is complex and difficult. The main idea of modeling the two-stage DC-DC-AC converter states that this topology is separated into a bidirectional DC-DC converter and a single-phase inverter with an equivalent current source corresponding to that of the inverter or converter. The dynamic equations for the separated converter and inverter are then derived using the state-space averaging technique. The procedures of building the small-signal model of the two-stage DC-DC-AC converter are described in detail. Based on the derived small-signal model, the individual controllers are designed through a frequency-domain analysis. The simulation and experimental results verify the validity of the proposed modeling approach and controller design.

다단 임팩터(MOUDI)의 조대 입자 채취 특성 (Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles)

  • 배귀남;지준호;문길주
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF