• Title/Summary/Keyword: Single-photon emission tomography

Search Result 165, Processing Time 0.031 seconds

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

Value of Bone Scintigraphy and Single Photon Emission Computed Tomography (SPECT) in Lumbar Facet Disease and Prediction of Short-term Outcome of Ultrasound Guided Medial Branch Block with Bone SPECT

  • Koh, Won-Uk;Kim, Sung-Hoon;Hwang, Bo-Young;Choi, Woo-Jong;Song, Jun-Gul;Suh, Jeong-Hun;Leem, Jeong-Gill;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2011
  • Background: Facet joint disease plays a major role in axial low-back pain. Few diagnostic tests and imaging methods for identifying this condition exist. Single photon emission computed tomography (SPECT) is reported that it has a high sensitivity and specificity in diagnosing facet disease. We prospectively evaluated the use of bone scintigraphy with SPECT for the identification of patients with low back pain who would benefit from medial branch block. Methods: SPECT was performed on 33 patients clinically suspected of facet joint disease. After SPECT, an ultrasound guided medial branch block was performed on all patients. On 28 SPECT-positive patients, medial branch block was performed based on the SPECT findings. On 5 negative patients, medial branch block was performed based on clinical findings. For one month, we evaluated the patients using the visual analogue scale (VAS) and Oswestry disability index. SigmaStat and paired t-tests were used to analyze patient data and compare results. Results: Of the 33 patients, the ones who showed more than 50% reduction in VAS score were assigned 'responders'. SPECT positive patients showed a better response to medial branch blocks than negative patients, but no changes in the Oswestry disability index were seen. Conclusions: SPECT is a sensitive tool for the identification of facet joint disease and predicting the response to medial branch block.

Renal Manifestations and Imaging Studies of Kawasaki Disease (가와사키 질환에서의 신증상과 영상 검사 소견)

  • Oh, Ji Young;Park, Se Jin;Kim, Sun Jung;Jang, Gwang-Cheon;Kim, Uria;Shin, Jae Il;Kim, Kee Hyuck
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.86-91
    • /
    • 2013
  • Purpose: The aim of this study was to verify renal inflammation following Kawasaki disease (KD) using single photon emission computed tomography along with Technetium-99m dimercaptosuccinic acid scintigraphy (DMSA renal SPECT). Methods: From March 2011 to October 2011, 15 patients diagnosed with KD at the National Health Insurance System Ilsan Hospital were enrolled in the study. All patients underwent DMSA renal SPECT to evaluate renal involvement during the acute phase of KD. Urine ${\beta}2$-microglobulin (${\beta}2$-MG), a marker of renal proximal tubular dysfunction, was also measured to assess renal damage. Results: All 15 patients had normal renal function test results. However, microscopic hematuria and pyuria were observed in 13% and 33% of the patients, respectively. Moreover, urine ${\beta}2$-MG was elevated in 46% of the patients. In addition, patients were divided into two groups based on ${\beta}2$-MG level: those with an increased ${\beta}2$-MG level, and those with a normal ${\beta}2$-MG level. No significant differences were found between these two groups in clinical characteristics, laboratory, sonography, and echocardiography findings. All patients' DMSA renal SPECT scans were normal. Conclusion: Our study showed that mild abnormalities in the urinalysis and elevated urine ${\beta}2$-MG were the only findings of renal involvement in KD. However, no aggressive renal manifestations were detected on DMSA renal SPECT.

Comparison of Circular vs Non-Circular Orbit Data Acquistion using Single Head Single Photon Emission Computed Tomography (SPECT) (단일검출기 단일광자방출 전산화단층촬영술에서 원형(Circular)과 비원형(Non-circular) 회전방식 자료획득(Data Acquisition)의 비교)

  • Sohn, Hyung-Sun;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.118-124
    • /
    • 1995
  • 단일광자방출전산화 단층촬영술을 이용한 영상정보를 효과적으로 얻기 위하여 고려되어야 할 사항으로는 1) 조준기(collimator)의 선택, 2) 기질(matrix)의 크기, 3) 회전각의 수 (number of angles), 4) 360도 또는 180도 획득(acquisition), 5) continuous 또는 step& shoot, 6) 원형 또는 비원형회전 등이 있다. 저자들은 비원형회전으로 검체와 검출기 사이의 거리를 단축시킴으로써 직선성, 균일성, 대조도, 해상력에 미치는 영향을 알아보기 위하여 원형회전 방법과 비교하여 다음과 같은 결과를 얻었다. (1) 비원형회전을 하여도 균일성(uniformity)과 직선성(linearlity)을 유지한다. (2) 균일성, 대조도(contrast), 해상력(resolution)들이 비원형 회전을 한 경우에 보다 더 개선되었다. (3) 영상 획득시간은 비원형회전인 경우에 더 소요되었다. (매스캔 당 10분) 따라서 검사자는 영상 화질의 개선효과와 상반되는 보정(calibration)과 설치(set-up)에 소요되는 시간(매스캔당 10분이상)을 비교하여 자료획득(data acquisition) 회전방법을 선택하여야한다.

  • PDF

The acupuncture mechanism related brain in Medline and the journal of Korean acupuncture & moxibustion (PubMed와 대한침구학회지(大韓針灸學會誌) 논문(論文) 검색(檢索)을 통(通)한 침요법(鍼療法)과 뇌(腦)와의 관계(關係)에 대한 연구동향(硏究動向) 고찰(考察))

  • Kim, Hoo-Dong;Koh, Hyung-Kyun;Kim, Chang-Hwan
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.188-200
    • /
    • 2001
  • Background and Objetive : Acupuncture is a valuable method of oriental medicine with broad application in many disease. It is based on the experiences of traditional oriental medicine as well as on experimentally proven biological (biochemical and neurophysiological) effects. Acupuncture theory has been explained by the meridian system that is thought to be linked with particular organs. However, in western medicine it is held that many disorders are either controlled or affected by the brain. Material and Method : In order to review the studies concerned with the mechanism related brain, we have referred to the Pubmed site and the Journal of Korean acupuncture and moxibustion Result and Conculsion : Among the 12 studies in the Journal of Korean acupuncture and moxibustion, 8 papers related neurotransmitters were done by experimental study, 4 papers related brain mapping were done by clinical study. Among the 8 studies related brain mapping in the Pubmed site, 6 clinical studies using functional magnetic resonance imaging(fMRI) were done and I clinical study using single-photon emission computed tomography(SPECT) was done, I paper was review article. By the above result, it would be needed further research on the acupuncture mechanism related brain using SPECT, fMRI, positron emission tomography(PET) etc.

  • PDF

Recent Advances in Nuclear Medicine Imaging Instrumentation (핵의학 영상기기의 최근 진보)

  • Jung, Jin-Ho;Choi, Yong;Hong, Key-Jo;Min, Byung-Jun;Hu, Wei;Kang, Ji-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

Metabolic impairment pattern analysis of the Alzheimer's disease (Alzheimer's Disease의 대사영상패턴 분석)

  • Juh, Ra-Hyeong;Lee, Chang-Uk;Chung, Yong-An;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.91-95
    • /
    • 2004
  • Several MRI studies have reported reductions in temporal lobe volumes in Alzheimer's disease (AD). Measures have been usually obtained with regions-of-interest (ROI) drawn manually on selected medial and lateral portions of the temporal lobes, with variable choices of anatomical borders across different studies. We used the automated voxel-based morphometry (VBM) approach to investigate gray matter abnormalities over the entire extension of the temporal lobe in 10AD patients (MM5E 22)and 22 healthy controls. Foci of significantly reduced gray matter volume in AD patients were detected in both medial and lateral temporal regions, most significantly in the right and left posterior parahippocarmpal gyri. At a more flexible statistical threshold (P<0.01, uncorrected for multiple comparisons), circumscribed foci of significant gray matter reduction were also detected in the right amygdala/enthorinal cortex, the anterior and posterior borders of the superior temporal gyrus bilaterally, and the anterior portion of the left middle temporal gyrus. These VBM results confirm previous findings of temporal lobe atrophic changes in AD, and suggest that these abnormalities may be confined to specific sites within that lobe, rather than showing a widespread distribution.

  • PDF

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Radio-Iodinated arbutin for tumor imaging

  • Huynh, Phuong Tu;Ha, Yeong Su;Lee, Woonghee;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.72-79
    • /
    • 2017
  • Arbutin is a hydroquinone derivative with a glucose moiety. As a tyrosinase inhibitor, it is widely used as a skin-whitening cosmetic agent for the treatment of cutaneous hyperpigmentary disorders, such as melasma and freckles. In the medical field, many studies have addressed the use of arbutin in various tumors, but the mechanism for tumor uptake of arbutin is still unclear. In this paper, we radiolabeled arbutin using radioiodine and studied its pharmacokinetics and tumor uptake via biodistribution experiments and single-photon emission computed tomography (SPECT) imaging. Radiolabeled $^{131}I-arbutin$ was stable for up to 24 h in PBS and serum. Biodistribution studies and SPECT imaging indicated high uptake of the compound in the bladder and kidneys shortly after injection. Twenty-four hours post-injection, significant deiodination was observed. Apart from high thyroid uptake, selective tumor uptake was clearly observed. The tumor-to-muscle and tumor-to-blood ratios were 26 and 9, respectively.

A Novel In Situ Gel Formulation of Ranitidine for Oral Sustained Delivery

  • Xu, Haoping;Shi, Min;Liu, Ying;Jiang, Jinling;Ma, Tao
    • Biomolecules & Therapeutics
    • /
    • v.22 no.2
    • /
    • pp.161-165
    • /
    • 2014
  • The main purpose of this study was to develop a novel, in situ gel system for sustained delivery of ranitidine hydrochloride. Ranitidine in situ gels at 0.2%, 0.5%, and 1.0% gellan gum concentration (w/v) were prepared, respectively, and characterized in terms of preparation, viscosity and in vitro release. The viscosity of the gellan gum formulations in solution increased with increasing concentrations of gellan gum. In vitro study showed that the release of ranitidine from these gels was characterized by an initial phase of high release (burst effect) and translated to the second phase of moderate release. Single photon emission computing tomography technique was used to evaluate the stomach residence time of gel containing $^{99m}Tc$ tracer. The animal experiment suggested in situ gel had feasibility of forming gels in stomach and sustained the ranitidine release from the gels over the period of at least 8 h. In conclusion, the in situ gel system is a promising approach for the oral delivery of ranitidine for the therapeutic effects improvement.