• 제목/요약/키워드: Single-photon emission tomography

검색결과 165건 처리시간 0.026초

간질에서의 기능적 뇌영상:양전자방출단층촬영과 단일광전자방출 단층촬영 (Functional Neuroimaging in Epilepsy: FDG-PET and SPECT)

  • 이상건;이동수
    • 대한핵의학회지
    • /
    • 제37권1호
    • /
    • pp.24-33
    • /
    • 2003
  • Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. Ictal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

관상동맥질환에서 심장 하이브리드 영상의 임상적 이용 (Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease)

  • 조인호;공은정
    • Journal of Yeungnam Medical Science
    • /
    • 제26권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성 (Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography)

  • 배문선;문대혁
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Associations between Brain Perfusion and Sleep Disturbance in Patients with Alzheimer's Disease

  • Im, Jooyeon J.;Jeong, Hyeonseok S.;Park, Jong-Sik;Na, Seung-Hee;Chung, Yong-An;Yang, YoungSoon;Song, In-Uk
    • 대한치매학회지
    • /
    • 제16권3호
    • /
    • pp.72-77
    • /
    • 2017
  • Background and Purpose Although sleep disturbances are common and considered a major burden for patients with Alzheimer's disease (AD), the fundamental mechanisms underlying the development and maintenance of sleep disturbance in AD patients have yet to be elucidated. The aim of this study was to examine the correlation between regional cerebral blood flow (rCBF) and sleep disturbance in AD patients using technetium-99m hexamethylpropylene amine oxime single-photon emission computed tomography (SPECT). Methods A total of 140 AD patients were included in this cross-sectional study. Seventy patients were assigned to the AD with sleep loss (SL) group and the rest were assigned to the AD without SL group. SL was measured using the sleep subscale of the Neuropsychiatric Inventory. A whole-brain voxel-wise analysis of brain SPECT data was conducted to compare the rCBF between the two groups. Results The two groups did not differ in demographic characteristics, severity of dementia, general cognitive function, and neuropsychiatric symptoms, with the exception of sleep disturbances. The SPECT imaging analysis displayed decreased perfusion in the bilateral inferior frontal gyrus, bilateral temporal pole, and right precentral gyrus in the AD patients with SL group compared with the AD patients without SL group. It also revealed increased perfusion in the right precuneus, right occipital pole, and left middle occipital gyrus in the AD with SL group compared with the AD without SL group. Conclusions The AD patients who experienced sleep disturbance had notably decreased perfusion in the frontal and temporal lobes and increased rCBF in the parietal and occipital regions. The findings of this study suggest that functional alterations in these brain areas may be the underlying neural correlates of sleep disturbance in AD patients.

Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

게이트 심근 SPECT : 도약을 위한 준비 (Pulling Bowstring of Gated Myocardial SPECT)

  • 범희승
    • 대한핵의학회지
    • /
    • 제32권5호
    • /
    • pp.433-435
    • /
    • 1998
  • Recent progress of technology permits us to assess ventricular function and wall motion as well as myocardial perfusion using electrocardiographic gated myocardial perfusion single photon emission computed tomography (GM-SPECT). It is interesting that echocardiography and magnetic resonance imaging are moving in the same direction with the use of contrast medium to assess myocardial perfusion. A valid fundamental basis for a new technology is essential for a successful competition. Lee et al. report in this issue the reproducibility of serial measurement of left ventricular function including systolic wall thickening using a novel statistical method. It has important implications such as nitroglycerin or dobutamine application during GM-SPECT. The field of nuclear cardiology must continue to strive toward more sophisticated but straightforward evaluation of cardiac diseases.

  • PDF

Thallium-201 brain SPECT에서 양성 소견을 보인 출혈성 뇌경색 (Accumulation of Thallium-201 in Hemorrhagic Cerebral Infarction)

  • 이기열;김경민;최재걸;정용구
    • 대한핵의학회지
    • /
    • 제33권3호
    • /
    • pp.337-340
    • /
    • 1999
  • Thallium-201 brain SPECT is utilized in the diagnosis of brain tumor especially in cases where CT or MRI findings alone cannot differentiate malignant lesion from benign. Recently we came across two cases of positive T1-201 brain SPECT in clinically suspected brain tumor patients that turned out to be hemorrhagic cerebral infarction instead on biopsy. The findings in these cases demonstrate that thallium-201 accumulation may occur by the breakdown of the blood-brain barrier and phagocytic cell infiltration in the liquefaction stage of infarction.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • 제47권5호
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

SPECT 회전중심 측정에 있어서 콜리메타의 영향 (The Influence of Collimators on SPECT COR Measurements)

  • 이만구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.89-94
    • /
    • 1996
  • Misalignment between the electronic and mechanical axes of rotation will result in artifact generation and image degradation during single photon emission computed tomography(SPECT) reconstruction. Acceptance and quality control testing procedures have not emphasized the variability in center of rotation(COR) measurements caused by collimators and the need to verify uniformity across the full collimator field of view (FOV). Variation from the mean COR across the FOV was tested in four different collimators using multiple point source acquisitions. The mean COR was different for each collimator and one of the four had a > 0.5 pixel difference from the mean COR on some area of the FOV, This variation makes this collimator unacceptable for SPECT acquisition. Thus, initial acceptance testing of SPECT collimators should verify a uniform COR across the full FOV and collimators with a variability from the mean COR > 0.5 pixels should be rejected.

  • PDF