• Title/Summary/Keyword: Single-cell Measurement

Search Result 115, Processing Time 0.025 seconds

A Clinical Evaluation of the Tumor Volume Doubling Time in Primary Bronchogenic Carcinoma (폐암환자에서 본 Tumor Doubling Time 의 임상적 의의)

  • 홍기우;이홍균
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.15-22
    • /
    • 1973
  • The definition of cancer, its diagnosis and its prognosis all depend upon description of growth. To the layman a synonym for cancer is a "growth". There are no quantitative terms for the description of growth or growth rate in clinical use. There has been no attempt to assign values that would define "rapidly" or "slowly" growing. Estimates of growth potentiality are implied in the descriptive phrases "poorly differentiated" or "well differentiated", "highly malignant" or "low grade malignancy". and in systems of grading. These qualifying terms represent a personal impression, clinically useful in prognosis, but relative in nature. They do not lend themselves to uniform application or precise measurement for purpose of comparison. Growth is related to size and time. The volume of tumor depends upon the duration of the period of growth and the rate of growth. If the interval and change in volume are known. the average growth rate can be determined. If the growth rate is determined, and assumed to be constant., the duration of a given tumor and the time of inception can be estimated. The commonest concept of the origin of cancer is that as a result of a mutation involving a single cell, succeeding divisions of cells establish a colony with the characteristics recognizable as cancer. If the growth rate of the hypothetical tumor were constant it could be described in terms of "tumor volume doubling time". In the department of thoracic surgery of St. Mary hospital in Catholic Medical College, a clinical evaluation for the growth rate, degree of malignancy, resectability and prognosis was done on a total 24 cases of primary bronchogenic carcinoma which contour was significant on the chest X-ray film as possible estimating the tumor volume doubling time. The following results were obtained: 1. In the cases of 6.0cm or more in diameter of minor size at operation the resectability rate was lower and in the cases of 60 days or more in the tumor or volume doubling time the resectability rate was higher. 2. If differentiation of cancer cells was lower graded in tissue pathology, the tumor volume was shorter and the resectability rate was lower. 3. The tumor volume doubling time of the primary bronchogenic carcinoma occured more over 60 years of age was slightly shorter than under 60 years of age. 4. The tumor size at operation was more important to evaluate the survival time and prognosis than the tumor volume doubling time because the tumor growth was not always constant, we presume.mor volume doubling time because the tumor growth was not always constant, we presume.

  • PDF

A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon (실내 체적과 라돈 농도와의 상관관계 연구)

  • Kang, Sung-A;Han, Dong-Hyun;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.97-104
    • /
    • 2007
  • The corelation between the indoor volume and the measured radon concentration has been analyzed by comparing the radon concentration and the indoor volume of apartment rooms in Jeonju City. We also measured the annual exposure dose based on the variation in indoor radon concentration over time. To do this, we took 8 larger rooms and 8 smaller rooms of apartment, respectively, as a sample. The average volume of the larger rooms and that of the smaller rooms were $31.59\;m^3$ and $16.82\;m^3$, respectively. The average radon concentration of the larger rooms and that of the smaller rooms turned out to be $71.73\;Bq/m^3$ and $108.51\;Eq/m^3$, respectively. indicating that indoor volume is in inverse proportion to the radon concentration, i.e., the bigger the ratio of the surface area/volume, the higher the indoor radon concentration. From the measurement of the variation in indoor radon concentration over time fur a single day, the average intraday radon concentration variation was found to be about $46.8\;Bq/m^3$. The highest level of concentration ($114.5\;Bq/m^3$) was measured between 8 and 10 AM and the lowest level of concentration ($67.7\;Bq/m^3$) between 2 and 4 PM. The annual exposure dose turned out to be in the range of 0.3 mSv/yr to 2.16 mSv/yr, showing that the dose in some apartments exceeded 1.3 mSv/yr, the numerical value presented by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR).

The Future of NVH Research - A Challenge by New Powertrains

  • Genuit, Ing. K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.48-48
    • /
    • 2010
  • Sound quality and NVH-issues(Noise, Vibration and Harshness) of vehicles has become very important for car manufacturers. It is interpreted as among the most relevant factors regarding perceived product quality, and is important in gaining market advantage. The general sound quality of vehicles was gradually improved over the years. However, today the development cycles in the automotive industry are constantly reduced to meet the customers' demands and to react quickly to market needs. In addition, new drive and fuel concepts, tightened ecological specifications, increase of vehicle classes and increasing diversification(increasing market for niche vehicles), etc. challenge the acoustic engineers trying to develop a pleasant, adequate, harmonious passenger cabin sound. Another aspect concerns the general pressure for reducing emission and fuel consumption, which lead to vehicle weight reductions through material changes also resulting in new noise and vibration conflicts. Furthermore, in the context of alternative powertrains and engine concepts, the new objective is to detect and implement the vehicle sound, tailored to suit the auditory expectations and needs of the target group. New questions must be answered: What are appropriate sounds for hybrid or electric vehicles? How are new vehicle sounds perceived and judged? How can customer-oriented, client-specific target sounds be determined? Which sounds are needed to fulfil the driving task, and so on? Thus, advanced methods and tools are necessary which cope with the increasing complexity of NVH-problems and conflicts and at the same time which cope with the growing expectations regarding the acoustical comfort. Moreover, it is exceedingly important to have already detailed and reliable information about NVH-issues in early design phases to guarantee high quality standards. This requires the use of sophisticated simulation techniques, which allow for the virtual construction and testing of subsystems and/or the whole car in early development stages. The virtual, testing is very important especially with respect to alternative drive concepts(hybrid cars, electric cars, hydrogen fuel cell cars), where complete new NVH-problems and challenges occur which have to be adequately managed right from the beginning. In this context, it is important to mention that the challenge is that all noise contributions from different sources lead to a harmonious, well-balanced overall sound. The optimization of single sources alone does not automatically result in an ideal overall vehicle sound. The paper highlights modern and innovative NVH measurement technologies as well as presents solutions of recent NVH tasks and challenges. Furthermore, future prospects and developments in the field of automotive acoustics are considered and discussed.

  • PDF

Radioimmunoassay Reagent Survey and Evaluation (검사별 radioimmunoassay시약 조사 및 비교실험)

  • Kim, Ji-Na;An, Jae-seok;Jeon, Young-woo;Yoon, Sang-hyuk;Kim, Yoon-cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.34-40
    • /
    • 2021
  • Purpose If a new test is introduced or reagents are changed in the laboratory of a medical institution, the characteristics of the test should be analyzed according to the procedure and the assessment of reagents should be made. However, several necessary conditions must be met to perform all required comparative evaluations, first enough samples should be prepared for each test, and secondly, various reagents applicable to the comparative evaluations must be supplied. Even if enough comparative evaluations have been done, there is a limit to the fact that the data variation for the new reagent represents the overall patient data variation, The fact puts a burden on the laboratory to the change the reagent. Due to these various difficulties, reagent changes in the laboratory are limited. In order to introduce a competitive bid, the institute conducted a full investigation of Radioimmunoassay(RIA) reagents for each test and established the range of reagents available in the laboratory through comparative evaluations. We wanted to share this process. Materials and Methods There are 20 items of tests conducted in our laboratory except for consignment tests. For each test, RIA reagents that can be used were fully investigated with the reference to external quality control report. and the manuals for each reagent were obtained. Each reagent was checked for the manual to check the test method, Incubation time, sample volume needed for the test. After that, the primary selection was made according to whether it was available in this laboratory. The primary selected reagents were supplied with 2kits based on 100tests, and the data correlation test, sensitivity measurement, recovery rate measurement, and dilution test were conducted. The secondary selection was performed according to the results of the comparative evaluation. The reagents that passed the primary and secondary selections were submitted to the competitive bidding list. In the case of reagent is designated as a singular, we submitted a explanatory statement with the data obtained during the primary and secondary selection processes. Results Excluded from the primary selection was the case where TAT was expected to be delayed at the moment, and it was impossible to apply to our equipment due to the large volume of reagents used during the test. In the primary selection, there were five items which only one reagent was available.(squamous cell carcinoma Ag(SCC Ag), β-human chorionic gonadotropin(β-HCG), vitamin B12, folate, free testosterone), two reagents were available(CA19-9, CA125, CA72-4, ferritin, thyroglobulin antibody(TG Ab), microsomal antibody(Mic Ab), thyroid stimulating hormone-receptor-antibody(TSH-R-Ab), calcitonin), three reagents were available (triiodothyronine(T3), Tree T3, Free T4, TSH, intact parathyroid hormone(intact PTH)) and four reagents were available are carcinoembryonic antigen(CEA), TG. In the secondary selection, there were eight items which only one reagent was available.(ferritin, TG, CA19-9, SCC, β-HCG, vitaminB12, folate, free testosterone), two reagents were available(TG Ab, Mic Ab, TSH-R-Ab, CA125, CA72-4, intact PTH, calcitonin), three reagents were available(T3, Tree T3, Free T4, TSH, CEA). Reasons excluded from the secondary selection were the lack of reagent supply for comparative evaluations, the problems with data reproducibility, and the inability to accept data variations. The most problematic part of comparative evaluations was sample collection. It didn't matter if the number of samples requested was large and the capacity needed for the test was small. It was difficult to collect various concentration samples in the case of a small number of tests(100 cases per month or less), and it was difficult to conduct a recovery rate test in the case of a relatively large volume of samples required for a single test(more than 100 uL). In addition, the lack of dilution solution or standard zero material for sensitivity measurement or dilution tests was one of the problems. Conclusion Comparative evaluation for changing test reagents require appropriate preparation time to collect diverse and sufficient samples. In addition, setting the total sample volume and reagent volume range required for comparative evaluations, depending on the sample volume and reagent volume required for one test, will reduce the burden of sample collection and planning for each comparative evaluation.

Expression of CsRCI2s by NaCl stress reduces water and sodium ion permeation through CsPIP2;1 in Camelina sativa L.

  • Kim, Hyun-Sung;Lim, Hyun-Gyu;Ahn, Sung-Ju
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.194-194
    • /
    • 2017
  • Camelina (Camelina sativa L.) is a potential bio-energy crop that has short life cycle about 90 days and contains high amount of unsaturated fatty acid which is adequate to bio-diesel production. Enhancing environmental stress tolerance is a main issue to increase not only crop productivity but also big mass production. CsRCI2s (Rare Cold Inducible 2) are cold and salt stress related protein that localized at plasma membrane (PM) and assume to be membrane potential regulation factor. These proteins can be divide into C-terminal tail (CsRCI2D/E/F/G) or no-tail group (CsRCI2A/B/C/H). However, function of CsRCI2s are less understood. In this study, physiological responses and functional characterization of CsRCI2s of Camelina under salt stress were analyzed. Full-length CsRCI2s (A/B/E/F) and CsPIP2;1 sequences were confirmed from Camelina genome browser. Physiological investigations were carried out using one- or four-week-old Camelina under NaCl stress with dose and time dependent manner. Transcriptional changes of CsRCI2A/B/E/F and CsPIP2;1 were determined using qRT-PCR in one-week-old Camelina seedlings treated with NaCl. Translational changes of CsRCI2E and CsPIP2;1 were confirmed with western-blot using the antibodies. Water transport activity and membrane potential measurement were observed by cRNA injected Xenopus laevis oocyte. As results, root growth rate and physiological parameters such as stomatal conductance, chlorophyll fluorescence, and electrolyte leakage showed significant inhibition in 100 and 150 mM NaCl. Transcriptional level of CsPIP2;1 did not changed but CsRCI2s were significantly increased by NaCl concentration, however, no-tail type CsRCI2A and CsRCI2B increased earlier than tail type CsRCI2E and CsRCI2F. Translational changes of CsPIP2;1 was constitutively maintained under NaCl stress. But, accumulation of CsRCI2E significantly increased by NaCl stress. CsPIP2;1 and CsRCI2A/B/E/F co-expressed Xenopus laevis oocyte showed decreased water transport activity as 61.84, 60.30, 62.91 and 76.51 % at CsRCI2A, CsRCI2B, CsRCI2E and CsRCI2F co-expression when compare with single expression of CsPIP2;1, respectively. Moreover, oocyte membrane potential was significantly hyperpolarized by co-expression of CsRCI2s. However, higher hyperpolarized level was observed in tail-type CsRCI2E and CsRCI2F than others, especially, CsRCI2E showed highest level. It means transport of $Na^+$ ion into cell is negatively regulated by expression of CsRCI2s, and, function of C-terminal tail is might be related with $Na^+$ ion influx. In conclusion, accumulation of NaCl-induced CsRCI2 proteins are related with $Na^+$ ion exclusion and prevent water loss by CsPIP2;1 under NaCl stress.

  • PDF