  • Poultry feeding systems are likely to change for increased efficiency of production. An experiment was conducted to compare the response of broilers to choice feeding of corn with a standard broiler ration. The treatments consisted of providing broiler feed as the only feed (SINGLE FEED) and access to corn as a choice to a complete broiler feed (CHOICE FEEDING). Weights and feed consumption were obtained at weekly intervals. Samples at the conclusion of the experiment were taken to determine the weight of abdominal fat. Results showed that there was no significant difference in term of liveweight between the two feeding regimes. However, birds given a choice of the broiler feed and corn had better feed efficiency which is reflected by the lower total feed intake. Corn intake was 23.1% of total feed intake in the choice fed birds. In term of carcass colour, birds fed corn as a choice was observed to have a deeper yellow skin colour than the birds fed with broiler feed only.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

Responses of Choice-Fed Red Jungle Fowl and Commercial Broiler Chickens Offered a Complete Diet, Corn and Soybean

  • Zulkifli, I.;Iman Rahayu, H.S.;Alimon, A.R.;Vidyadaran, M.K.;Babjee, S.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권12호
    • /
    • pp.1758-1762
    • /
    • 2001
  • Equal number of red jungle fowl (JF) and commercial broiler chickens (CB), raised in battery cages, were provided a single complete diet (control) or a choice of a complete diet, ground corn and ground soybean from 21 to 56 days of age. There were significant genotype ${\times}$ feeding regimen interactions for several traits measured suggesting CB and JF responded differently to the two feeding regimens. The single fed CB had better growth and feed conversion ratios (FCR) than those under choice feeding. However, the body weight and FCR of JF were not affected by feeding regimen. While the single fed and choice-fed JF consumed similar amount of protein during days 21 to 55, the protein intake of the choice-fed CB was lower than the control. From days 21 to 55, irrespective of genotype, choice-fed chicks consumed less energy than their single fed counterparts. Regardless of genotype, the trend in the proportion of each feed consumed was similar with complete diet>corn>soybean. In conclusion, while choice-fed JF were capable to select nutrient necessary for maximum growth, choice feeding was detrimental to growth and feed conversion ratio in CB.

Single-Feed, Wideband, Circularly Polarized, Crossed Bowtie Dipole Antenna for Global Navigation Satellite Systems

  • Tran, Huy Hung;Ta, Son Xuat;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권3호
    • /
    • pp.299-305
    • /
    • 2014
  • A wideband circularly polarized (CP) antenna with a single feed is proposed for use in global navigation satellite systems. Its primary radiation elements are composed of two orthogonal bowtie dipoles, which are equipped with double-printed vacant-quarter rings to allow direct matching of the antenna to a single $50-{\Omega}$ coaxial line and to produce CP radiation. The crossed bowtie dipole is appropriately incorporated with a planar metallic reflector to produce the desired unidirectional radiation pattern as well as to achieve a wideband characteristic in terms of impedance matching and axial ratio (AR) bandwidths. The designed antenna was fabricated and measured. The prototype antenna with an overall 1.2-GHz frequency size of $0.48{\lambda}_o{\times}0.48{\lambda}_o{\times}0.25{\lambda}_o$ produced a measured ${\mid}S_{11}{\mid}$<-10 dB bandwidth of 1.05-1.79 GHz and a measured 3-dB AR bandwidth of 1.12-1.64 GHz. It also showed right-hand CP radiation with a small gain variation (${\pm}0.3dB$) and high radiation efficiency (>93%) over the operational bandwidth.

Floating zone법에 의한 결정성장시 소결봉의 미세구조에 의한 영향 (Effects of microstructures of the sintered rod on the single crystal grown by the floating zone method)

  • 신재혁;오근호
    • 한국결정성장학회지
    • /
    • 제5권3호
    • /
    • pp.250-260
    • /
    • 1995
  • 일반적으로 floating zone법에 의한 결정성장시에는 소결봉이 원료로서 사용되며 이러한 원료봉의 소결조건에 의해 결정성장시 안정성이 영향을 받게 된다. 그 원인은 FZ법에 의한 결정성장시 소결조건에 따른 원료봉의 미세구조의 변화가 소결봉과 융액사이의 계면형태를 변화시키기 때문이다. 본 연구에서 FZ법에 의해 $TiO_2$(rutile)과 ruby 단결정을 성장하였으며 이를 통해 소결봉의 미세구조가 FZ법에 의한 결정성장시에 용융대의 안정서에 미치는 영향을 분석하였다.$TiO_2$(rutile)과 ruby의 결정성장에 사용되는 원료봉의 소결시 소결온도가 높아지고 소결시간이 길어질수록 원료봉 중앙부와 바깥ㅂ분의 입자크기의 차이가 커져서 결국에는 그로 인하여 원료봉의 용융양상이 바뀌어졌다. FZ법에 의한 결정성장시 원료봉의 최적소결 조건은 입자의 크기가 소결봉 전영역에 걸쳐 균일하게 분포되는 것이었다. 반면 일반 적으로 중요하다고 여기는 소결봉의 porosity는 FZ법에 의한 결정성장시 영향력 있는 인자가 아니라는 점을 소결하지 않은 원료봉을 사용해 결정성장 실험을 행하여 봄으로써 확인할 수 있었다.

  • PDF

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF

DIVERGENT SELECTION FOR POSTWEANING FEED CONVERSION IN ANGUS BEEF CATTLE VI. REALIZED HERITABILITY ESTIMATES

  • Park, N.H.;Bishop, M.D.;Davis, M.E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권4호
    • /
    • pp.475-479
    • /
    • 1994
  • Postweaning performance data were obtained on 401 group fed purebred Angus calves from 24 selected sires (12 high and 12 low feed conversion sires) from 1983 through 1986 at the Northwestern Branch of the Ohio Agricultural Research and Development Center. A single generation divergent selection experiment was replicated four times (1983, 1984, 1985 and 1986) to obtain an realized heritability estimate for postweaning feed conversion. The 140-d postweaning period was divided into five 28-d periods. Realized heritability estimates for feed conversion by 28-d periods fluctuated greatly and demonstrated no particular pattern. Heritability was highest for the fourth period (between d 85 and 112 of postweaning period, 0.61). Thus, beef producers could successfully select for feed conversion.

정면밀링에서 절삭력을 이용한 반경방향 절입비와 순간 절삭력 성분 사이의 비 추정 (Estimation of Radial Immersion Ratio and Instantaneous Ratio between Cutting Force Components using Cutting Force in Face Milling)

  • 김명곤
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.239-244
    • /
    • 1999
  • Radial immersion ratio is an important factor to determine the threshold in face milling and should be estimated in process for automatic force regulation. In this paper, presented is a method of on-line estimation of radial immersion ratio using cutting force. When a tooth finishes sweeping, sudden drop of cutting forces occurs. These force drops are equal to the cutting forces that act on a single tooth at the swept angle of cut and can be acquired from cutting force signals in feed and cross-feed directions. The ratio of cutting forces in feed and cross-feed directions acting on the single tooth at the swept angle of cut is a function of the swept angle of cut and the ratio of radial to tangential cutting force. In the research, it is found that the ratio of radial to tangential cutting force is not affected by cutting conditions and axial rake angle. Therefore, the ratio of radial to tangential cutting force determined by just one preliminary experiment can be used regardless of the cutting conditions. Using the measured cutting forces and predetermined ratio, the redial immersion ratio is estimated. various experiments show that the radial immersion ratio can be estimated by the proposed method very well.

  • PDF

난용계 육성기 사료의 에너지 수준이 육성계의 성장 및 영양소 섭취량과 산란능력에 미치는 영향 (Effect of Dietary Energy Levels for Egg-type Growing Puilets on Pullet Growth, Nutrient Consumption and Subsequent Laying Performance)

  • 이규호;정연종
    • 한국가금학회지
    • /
    • 제21권4호
    • /
    • pp.267-275
    • /
    • 1994
  • Three dietary ME levels of 3,200, 2,900 and 2,600 kcal /kg in the same 13% single-stage low protein diet were compared to evaluate the effect of ME levels of grower diets on egg-type pullet growth and subsequent laying performance. As the ME levels of grower diets decreased, cumulative feed and protein consumptions increased(P<0.05), however, the ME intake and body weight at 18 wk of age decreased(P<0.05). Grower feed cost decreased as the dietary ME level was decreased, but no significant difference was found among dietary ME levels of grower diets. During the laying period, sexual maturity, hen-day egg production and average egg weight were not significantly affected by the ME levels of grower diet, however, daily feed intake and feed required per egg decreased as the dietary ME level of grower diet was reduced(P<0.05). Results of this study indicate that pullets can be reared on the low ME diet of 2,600 kcal /kg and it would he economical to utilize the low energy diet during the growing period when they are reared on a 13% single-stage low protein diet.

  • PDF

인터넷데이터센터의 교류, 직류급전시스템 비교 분석 (Comparative Study on AC and DC Feed System for Internet Data Center)

  • 김두환;김효성
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.27-33
    • /
    • 2012
  • Internet Data Centers (IDC), as essential facilities for modern IT industry, typically have scores of MW of concentrated electric loads. Uninterruptible Power Supplies (UPS) are necessary for the power feed system of IDCs because of stable power requirement. Thus, conventional AC power feed systems of IDCs have three cascaded power conversion stages such as (AC-DC), (DC-AC), and (AC-DC), which results in very low conversion efficiency. On the contrary, DC power feed systems need just a single power conversion stage (AC-DC) supplying AC mains power to DC server loads, which gives comparatively high conversion efficiency and reliability. This paper compares the efficiencies between 220V AC power feed system and 300V DC power feed system on equal load conditions which were established in Mok-Dong IDC of Korea Telecom company (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is around 15% higher than that of the 220V AC power feed system.