• 제목/요약/키워드: Single vision lenses

검색결과 20건 처리시간 0.021초

Relationship between Surface Sag Error and Optical Power of Progressive Addition Lens

  • Liu, Zhiying;Li, Dan
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.538-543
    • /
    • 2017
  • Progressive addition lenses (PAL) have very wide application in the modern glasses market. The unique progressive surface can make a lens have progressive refractive power, which can meet the human eye's different needs for distance-vision and near-vision. According to the national glasses fabrication standard, the difference between actual optical power after fabrication and nominal design value should be less than 0.1D over the lens effective area. The optical power distribution of PAL is determined directly by the surface. Consequently, the surface processing accuracy requirement is proposed. Beginning from the surface expressions of progressive addition lenses, the relationship equations between the surface sag and optical power distribution are derived. They are demonstrated through tolerance analysis and test of an example progressive addition lens with addition of 2.09D (5.46D-7.55D). The example addition surface is fabricated under given accuracy by a single-point diamond ultra-precision machine. The optical power of the PAL example is tested with a focal-meter after fabrication. The optical power addition difference between test result and design nominal value is 0.09D, which is less than 0.1D. The derived relationship between the surface error and optical power is verified from the PAL example simulation and test result. It can provide theoretical tolerance analysis proof for the PAL surface fabricating process.

베이스 커브에 의한 콘택트렌즈 피팅 효과 (Effects of Base Curve on Fitting with the current Soft Contact Lenses)

  • 최오목;강명진
    • 한국안광학회지
    • /
    • 제5권2호
    • /
    • pp.65-72
    • /
    • 2000
  • 콘택트렌즈 피팅후 기초검사와 베이스커브의 무작위 피팅검사, 그리고 베이스커브의 의도적인 변화에 따른 재피팅검사율 이용하여 중함수의 소프트 콘택트렌즈의 피팅과 베이스커브의 효과에 대하여 조사하였다. 시험렌즈 피팅후 렌즈의 위치, 순목후 렌즈의 움직임, 자각적 착용감을 평가하여 적합한 베이스커브를 평가한 결과 본 연구에 사용한 소재의 소프트 콘택트렌즈에서는 베이스커브가 8.4mm의 경우 최상의 피팅 효과를 보였다. 베이스커브를 8.4mm보다 큰 경우 순목후 렌즈 움직임보다 피팅후 렌즈의 중심이탈정도가 심하고 자각적 검사결과 의도적인 재피팅을 시도하였다. 다른 제조회사렌즈는 정교한 디자인과 제조상의 차이 때문에 언제나 같은 방법으로 피팅 결과가 나오는 것은 아니다. 본 실험에 사용한 중함수율 소프트콘택트렌즈는 대다수의 눈에 최적의 피팅을 제공해 주는 것은 8.4mm 베이스커브렌즈가 효과적이었다.

  • PDF

Morphology of Retinas and Lenses in the Fish of the Genus Zacco (Cypriniformes, Cyprinidae): Possible Relationship with Prey and Habitat

  • Lim, Jae-Won;Lee, Chung-Lyul;Lee, Moo-Sam
    • Animal cells and systems
    • /
    • 제7권4호
    • /
    • pp.331-335
    • /
    • 2003
  • Vertebrates with different habitats have different proportions of visual cells, with the rod cells responding to scotopic vision and the cone cells responding to photopic and color vision in their retinas. The present work studied whether the kinds and arrangement patterns of the cone cells and interlocking morphology of the lens were related to the kind of preys and habitats in the genus Zacco. The retinas were observed by a light microscopy using H-E staining method and the interlocking formula of the lens fibers were investigated by a scanning electron microscopy. The interlocking formula of the lens fibers of Z. temmincki is an ' anchor and socket ' connection, and that of Z. platypus is a ' ball and socket ' connection. The cone cells of Z. platypus and Z. temmincki constituted compacted mosaic patterns of row type. Away from the center, the double and single cone cells gradually increased in diameter. Zacco temmincki had identical double cone cells and Z. platypus had non-identical double and single cone cells. The eyes of Z. temminckifeeding on a moving aquatic insects in relative limpid water and swift current of mid and upper stream have better resolution than that of Z. platypus feeding on mainly adhesive algae and some aquatic insects in slightly turbid water of mid stream.

대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구 (A study on Monovision of Fitting soft contact lenses for College students)

  • 김재민
    • 한국안광학회지
    • /
    • 제9권1호
    • /
    • pp.181-188
    • /
    • 2004
  • 모노비전은 한눈은 원용 시력을 위해 다른 눈은 근용시력을 위해 양안에 콘택트렌즈를 교정한 형태를 말한다. 단초점 콘택트렌즈가 각 눈에 이용되는데 환자는 다른 눈을 사용하는 동안 한 눈을 선택적으로 억제한다. 본 연구는 젊은 학생에게 +3.00D 가입시켜 인위적으로 유도된 모노비전의 양안시 기능과 환자 만족도를 측정하기 위해 시행하였다. 144명의 대학생을 대상으로 우위안 검사를 하여 비우위안에 +3.00D를 가입하여 원용 교정안경을 양안에 장용시켰다. 모노비전의 양안시 기능을 조사하기 위해 입체시 검사를 포함하여 장애물 코스, 물부어 담기, 던지기와 받기, 구슬 분류하기를 시행하여 정상 양안시 상태와 비교하였다. 그 결과 입체시는 현저하게 저하되었지만 장애물 코스, 물부어 담기, 던지기와 받기, 구슬 분류하기 등 양안시 기능에 대한 결과에는 차이가 거의 없었다. 따라서 본 연구를 통해 콘택트렌즈 모노비전은 환자 선택과 임상적 지식을 활용하여 처방하면 노안 교정을 위한 효과적이고 권장할 만한 방법이라는 것을 알 수 있었다. 그리고 이와 같은 방법을 응용하여 학생들의 모노비전에 대한 이해를 높이는 실습에도 효과적으로 활용될 것으로 사료된다.

  • PDF

거리측정이 가능한 단동형 수중 스테레오 카메라의 제어 (Control of an Underwater Stereo Camera Embedded in a Single Canister Capable of Measuring Distance)

  • 이판묵;전봉환;이종무
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.90-95
    • /
    • 2000
  • This paper presents the vergence control of a parallel stereo camera and its application to underwater stereo camera to enhance the working efficiency of underwater vehicles that equips with manipulators in seabed operation. The stereo camera consists of two parallel lenses mounted on a lateral moving base and two CCD cameras mounted on a longitudinal moving base, which is embedded in a small pressure canister for underwater application. Because the lateral shift is related to the backward shift with a nonlinear relation, only one control input is needed to control the vergence and focus of the camera with a special driving device. We can get a clear stereo vision with the camera for all the range of objects in air and in water, especially in short range objects. The control system of the camera is so simple that we are able to realize a small stereo camera system and to apply it to a stereo vision system for underwater vehicles. This paper also shows how to acquire the distance information of an underwater object with this stereo camera. Whenever we focus on an underwater object with the camera, we can obtain the three-dimensional images and the distance information in real-time.

  • PDF

거리측정이 가능한 단동형 수중 스테레오 카메라의 제어 (Control of an Underwater Stereo Camera Embedded in a Single Canister Capable of Measuring Distance)

  • 이판묵;전봉환;이종무
    • 한국해양공학회지
    • /
    • 제15권1호
    • /
    • pp.79-84
    • /
    • 2001
  • This paper present the control of the image disparity of a parallel stereo camera and its application to an underwater stereo camera to enhance the working efficiency of underwater vehicles that are equiped with manipulators in seabed operation. The stereo camera consists of two parallel lenses mounted on a lateral moving base and two CCD cameras mounted on a longitudinal moving base, which is embedded in a small pressure canister for underwater application. Because the lateral shift is related to the backward shift with a nonlinear relation, only one control input is needed to control the vergence and focus of the camera with a special driving device. We can get clear stereo vision with the camera for all the range of objects in air and in water, especially in short range object. The control system of the camera is so simple that we are able to realize a small stereo camera system and apply it to a stereo vision system for underwater vehicles. This paper also shows how to acquire the distance information of an underwater object with this stereo camera. Whenever we focus on an underwater object with the camera, we can obtain three-dimensional images and distance information in real-time.

  • PDF

모노비전, 변형된 모노비전, 멀티포컬 콘택트렌즈로 교정 시 20대 성인의 조절기능 비교 (Comparison of Accommodative Function of Young Adults in their Twenties Wearing Monovision, Modified Monovision and Multifocal Soft Contact Lenses)

  • 이아영;김정미;이군자
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.117-124
    • /
    • 2015
  • 목적: 모노비전, 변형된 모노비전 및 비구면 멀티포컬 소프트콘택트렌즈로 교정 시 20대 성인에서 근거리 작업 후 조절기능의 변화를 비교하였다. 방법: 30명의 젊은 성인($23.53{\pm}2.37$세)을 대상으로 모노비전, 단초점 콘택트렌즈와 낮은 가입도의 중심부-근용 비구면 다초점 콘택트렌즈를 활용한 변형된 모노비전, 멀티포컬 콘택트렌즈의 교정방법을 사용하여 양안에 착용시키고, 일주일의 적응기간이 경과한 후 조절기능을 검사하였다. 조절기능 평가는 콘택트렌즈를 착용하고 1시간 동안 동영상을 시청하여 조절 부담을 유도한 후 원/근거리의 100%와 10% 대비시력, 조절반응, 근거리 조절용이성, 양성/음성상대조절력 등을 평가하였다. 모든 검사는 양안으로 실행하였다. 결과: 원거리 10% 대비시력은 모노비전에서 가장 낮았다(p<0.005). 조절반응량은 검사거리 1 m(1.00 D)에서 모노비전이 변형된 모노비전보다 작았고, 검사거리 40 cm(2.50 D)에서는 모노비전이 변형된 모노비전, 멀티포컬 콘택트렌즈보다 작았다(p<0.05). 근거리 조절용이성, 양성/음성상대조절력은 콘택트렌즈 교정법 사이에 차이가 없었다. 결론: 20대 성인에서 낮은 가입도의 모노비전 처방은 단초점렌즈보다 근거리 조절반응을 줄여주지만 중심부-근용 멀티포컬 콘택트렌즈를 이용한 '변형된 모노비전'과 멀티포컬 콘택트렌즈 처방은 조절이완에 영향을 주지 않는 것으로 생각된다.

일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화 (Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses)

  • 박미정;양재헌;김선미;박상일;박상희;김소라
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.51-58
    • /
    • 2008
  • 목적: 본 연구에서는 일일 착용 렌즈를 2일 이상 착용 시 나타나는 문제점을 알아보고자 하였다. 방법: 3가지 다른 재질(etafilcon A, hilabilcon A, nelfilcon A)의 일일 착용 렌즈를 안질환이 없는 20대 19명이 1일 동안 착용하였을 때의 각막에서의 렌즈 중심 안정 위치 변화와 순목횟수의 변화를 측정하여 착용자가 불편감을 호소하여 렌즈를 더 이상 착용하지 못하였을 때와 비교하여 보았다. 결과: 착용 2일째에 10.5%의 착용자가 렌즈의 착용을 중단하였으며 3일째에는 전체의 47.4%가, 4일째에는 전체의 70.2%가 심한 이물감, 충혈, 건조감, 통증, 흐릿한 시야를 호소하며 착용을 중단하였다. 렌즈 착용을 중단한 시점에서의 순목후 렌즈의 중심안정위치는 1일 동안 렌즈를 착용한 후의 렌즈의 중심안정위치에 비해 각막중심 부위에서 많이 벗어나 있었다. 또한 착용기간이 2일 이상인 경우의 순목횟수는 일일 동안 렌즈를 착용한 경우에 비해 착용 중단 한 시점에서 약 80%의 착용자에서 증가하였다. 이러한 결과는 한 종류의 렌즈에 국한되어 나타나는 결과가 아니라 실험에 사용한 3 종류의 렌즈에서 모두 일반적으로 나타나는 결과였으며, 렌즈의 종류에 따라서 또한 개인에 따라서 정도의 차가 있었다. 결론: 이상의 결과에서 일일 착용 렌즈를 2일 이상 착용했을 때 렌즈 중심안정위치의 변화와 순목횟수의 증가로 시야의 흐릿함과 착용감 저하가 유발됨을 확인할 수 있었다. 또한 그 정도는 개인 및 렌즈의 종류에 따라서 그 차이가 크며, 이로 인하여 개인에 따 라서는 예상하지 못한 문제가 발생할 수 있을 가능성이 있어 이에 대한 충분한 고려가 필요함을 알 수 있었다.

  • PDF

버전스용이와 융합버전스의 관계 (Relationship Between Vergence Facility and Fusional Vergence)

  • 신효순
    • 한국안광학회지
    • /
    • 제14권3호
    • /
    • pp.37-42
    • /
    • 2009
  • 목적: 버전스용이가 융합버전스에 대해 임상적으로 의미 있는 추가정보를 제공하는지에 대해 명확하지 않다. 이 연구에서는 눈증상이 있는 집단을 대상으로 버전스용이와 융합버전스의 관계를 확인해보고자 한다. 방법: 선별검사 를 실시하여 선정된 눈증상이 있는 9세에서 13세 사이의 남여 114명을 대상으로 하였다. 버전스용이 검사는 8$\Delta$ BI/8$\Delta$ BO 플리퍼 렌즈와 단안 억제방지를 위해 Vectogram 9(Bernell, USA)의 20/30 시표를 사용하여 측정하였다. 근거리의 융합버전스는 20/30 수직단일시표를 사용하여 Von Graefe 기법을 이용하였고, 과다한 눈모임자극을 방지하기 위하여 음성 융합버전스 범위(흐린점, 분리점, 회복점)를 측정한 후 양성 융합버전스 범위(흐린점, 분리점, 회복점)를 측정 하였다. 결과: 버전스용이와 융합버전스의 다양한 측정값에 대해 실시한 Pearson 상관성 분석에서 버전스용이와 융합버전스의 어느 값과도 관련성이 없는 것으로 나타났다(p>0.05). 그리고 편안한 양안시를 위해 Sheard와 Morgan의 융합력 평가기준을 만족하는 경우와 만족하지 못하는 경우에 대한 버전스용이를 비교한 결과에서도 유의한 차이를 보이지 않았다(p>0.05). 결론: 증상이 있는 집단을 대상으로 한 버전스용이와 융합버전스는 관련성이 없음을 확인하였다. 따라서 양안시이상을 정확하게 진단하고 효율적인 관리계획을 수립하는데 도움을 주기위하여 버전스용이와 융합버전스를 모두 측정해야 할 것이다.

  • PDF

중심 구멍이 있는 구면거울과 평면거울을 이용한 가시광용 반사굴절식 전방위 광학계 (Catadioptric Omnidirectional Optical System Using a Spherical Mirror with a Central Hole and a Plane Mirror for Visible Light)

  • 서현진;조재흥
    • 한국광학회지
    • /
    • 제26권2호
    • /
    • pp.88-97
    • /
    • 2015
  • 전방위 광학계는 360도의 방위각과 지평선 위와 아래의 수직화각에 대한 상을 동시에 결상이 가능한 광학계이다. 본 논문에서는 제작을 쉽게 하면서 크기가 작아지도록 하기 위해서 가운데에 구멍이 뚫려있는 옵스큐레이션(obscuration)을 갖는 구면거울 1장과 평면거울 1장으로 이루어진 거울계 및 이 거울계에서 반사하여 구면거울의 옵스큐레이션을 통과한 시야각 범위 안의 광을 결상하는 구면렌즈 3개와 하나의 구면 이중렌즈로 구성된 결상렌즈계를 사용하는 가시광용 반사굴절식 전방위 광학계를 설계하고 제작하여 전방위 영상을 실제로 결상하였다. 그리고 자동차 앞, 뒷번호판의 영상을 보고 이 전방위 광학계의 통과 공간주파수를 측정하고, ISO 12233 차트의 영상으로부터 전방위 광학계의 수직화각을 측정하여 광학계의 성능을 평가하였다. 이 결과 전방위 광학계의 수직화각은 $+53^{\circ}{\sim}-17^{\circ}$이며, 방위각은 $360^{\circ}$이고, 3 m 거리에서 자동차 앞번호판의 숫자를 구별할 수 있었는데, 이는 135 lp/mm의 통과 공간주파수에 해당한다.