• Title/Summary/Keyword: Single phase

Search Result 5,328, Processing Time 0.034 seconds

Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side (공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템)

  • Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

FIR Linear Phase Filter Design Using Coefficients +1,0.-1 and Multiple Integrator (다중적분기 사용 +1, 0, -1 계수의 선형위상 FIR 필터의 설계)

  • Kim, Hyung-Myung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.12
    • /
    • pp.2046-2054
    • /
    • 1989
  • Improved algorithms are presented to design linear phase digital FIR filters with coefficients of +1,0,-1 only followed by a multiple integrator. It has been shown that the existing linear phase filter design concept for the single integrator(or, accumulator)case can be extended to the case of the multiple integrator. Linear phase conditions for the multiple integrators are summarized. Filter design methods with double or triple integrator are exploited in datail and its computer simulation results are presented to deduce the advantages of multiple integrator to the single integrator.

  • PDF

Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL (3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

Effect of Cosurfactant on Preparation of Silica Nanoparticles using Water in Oil Microemulsion of Nonionic Surfactant (보조계면활성제가 비이온 계면활성제의 Water in Oil 마이크로에멀젼을 이용한 실리카 나노입자 제조에 미치는 영향)

  • Kim, TaeHoon;Lim, JongChoo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.356-368
    • /
    • 2008
  • The effects of cosurfactant on silica nanoparticles were investigated in systems containing surfactant, oil and aqueous ammonia solution where nanoparticles were prepared using a single phase water-in-oil (W/O) microemulsion. For the same oil phase, a single phase region was dependent on the interaction between surfactant and oil. For the cyclohexane system, NP-5 surfactant showed a wider single phase region than NP-4. The addition of n-propanol as a cosurfactant resulted in an increase or a decrease of a single phase W/O microemulsion region depending on the continuous oil phase. For both cyclohexane and isooctane systems, the addition of n-propanol resulted in a decrease in the single phase region. On the other hand, for n-heptane system, the addition of n-propanol expanded a single phase W/O microemulsion region. Silica nanoparticles prepared within a single phase region showed that relatively large number of particles of irregular shape were obtained with the addition of n-propanol to NP surfactant system. The addition of n-propanol to LA-5 surfactant and n-heptane system produced a decrease in average particle size and an increase in the number of particles formed due to a decrease in the intermicellar exchange rate among microemulsion droplets.

Synthesis of Single Crystal and Polymorphism of KAlSiO4 (KAlSiO4의 단결정 합성 및 동질 다상)

  • 박병규;정수진
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.1
    • /
    • pp.73-77
    • /
    • 1988
  • Single crystals of kalsilite were synthesized by hydrothermal method at 420$^{\circ}C$-480$^{\circ}C$ and 100 atm-1500 atm. The crystal habits are similar to those of KLiSiO4 single crystals. The crystal structure was investigated by means of X-ray single crystal diffraction. The space group of kalsilite is P63. Phase transitiions were determined by use of DTA and high temperature X-ray Guinier camera. Phase transitions of kalsilite are summerized and discussed.

  • PDF

A Study on the Characteristics in Single-Phase Line-Start Permanent Magnet Moter (단상 유도형 동기 전동기(LSPM)의 특성해석에 관한 연구)

  • Jung, Dae-Sung;Kim, Seung-Ju;Lee, Jin-Hun;Choi, Jae-Hak;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.125-131
    • /
    • 2007
  • Electric motor efficient improvement from home appliance field is important to the effect reducing the energy consumption. But the electric motor design/analysis technology is still insufficient. Specially the electric motor design/analysis technology of satisfying characteristic of both the induction motor and the synchronous motor such as Line start permanent motor. Therefore the electric motor design/analysis technology is urgently demanded reliability. This paper proposes the sing1e-phase line-start permanent magnet motor to develop the motor it with be able to alternate the sing-phase induction motor it is a refrigerator compressor motor. The sing-phase induction motor is analyzed in the steady state. And we have a certification test to compare our single-phase line-start permanent magnet motor with the sing-phase induction motor. In order to improve the performance, the stator of the single-phase line-start permanent magnet motor is same as the stator of the sing-phase induction motor and changes the rotor form and has the permanent magnet. It used the Finite Element Method(FEM) which is widely used with electronic-magnetic field numerical analysis method.

Dielectric Properties and Phase Transformation of Poled <001>-Oriented Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystals (분극된 <001> 방위 Pb(Mg1/3Nb2/3)O3-PbTiO3 단결정의 유전 특성 및 상전이)

  • Lee, Eun-Gu;Lee, Jae-Gab
    • Korean Journal of Materials Research
    • /
    • v.22 no.7
    • /
    • pp.342-345
    • /
    • 2012
  • The dielectric properties and phase transformation of poled <001>-oriented $Pb(Mg_{1/3}Nb_{2/3})O_3-x%PbTiO_3$(PMN-x%PT) single crystals with compositions of x = 20, 30, and 35 mole% are investigated for orientations both parallel and perpendicular to the [001] poling direction. An electric-field-induced monoclinic phase was observed for the initial poled PMN-30PT and PMN-35PT samples by means of high-resolution synchrotron x-ray diffraction. The monoclinic phase appears from $-25^{\circ}C$ to $100^{\circ}C$ and from $-25^{\circ}C$ to $80^{\circ}C$ for the PMN-30PT and PMN-35PT samples, respectively. The dielectric constant (${\varepsilon}$)-temperature (T) characteristics above the Curie temperature were found to be described by the equation$(1/{\varepsilon}-1/{\varepsilon}_m)^{1/n}=(T-T_m)/C$, where ${\varepsilon}_m$ is the maximum dielectric constant and $T_m$ is the temperature giving ${\varepsilon}_m$, and n and C are constants that change with the composition. The value of n was found to be 1.82 and 1.38 for 20PT and 35PT, respectively. The results of mesh scans and the temperature-dependence of the dielectric constant demonstrate that the initial monoclinic phase changes to a single domain tetragonal phase and a to paraelectric cubic phase. In the ferroelectric tetragonal phase with a single domain state, the dielectric constant measured perpendicular to the poling direction was dramatically higher than that measured in the parallel direction. A large dielectric constant implies easier polarization rotation away from the polar axis. This enhancement is believed to be related to dielectric softening close to the morphotropic phase boundary.

Application of single phase D-Q rotating frame theory in a traction co-phase power supply system

  • Park, In Kwon;Elimban, Sumek;Zhang, Yi;Kuffel, Rick
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.216-218
    • /
    • 2017
  • The imbalance at the 3-phase side at the railway power supply substation has been a well-known issue. Due to the difference in status of loads at each phase at any given moment, it is difficult to maintain the balance in the 2-phase side of the transformer. Consequently, the 3-phase side also presents a certain level of imbalance as well. A co-phase power supply was proposed as a solution. The real application of such system is gradually expanding, proving the effectiveness of the system. In this paper, the application of the single phase D-Q rotating frame theory was applied to the control of the co-phase power supply system. In addition, the power stack of the system was composed of MMC valves, which offers superior operational characteristics. The effectiveness of the system was verified with a real-time simulation, and the results are presented.

  • PDF

Digital Control Strategy for Single-phase Voltage-Doubler Boost Rectifiers

  • Cho, Young-Hoon;Mok, Hyung-Soo;Ji, Jun-Keun;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.623-631
    • /
    • 2012
  • In this paper, a digital controller design procedure is presented for single-phase voltage-doubler boost rectifiers (VDBR). The model derivation of the single-phase VDBR is performed in the s-domain. After that the simplified equivalent z-domain models are derived. These z-domain models are utilized to design the input current and the output dc-link voltage controllers. For the controller design in the z-domain, the traditional K-factor method is modified by considering the nature of the digital controller. The frequency pre-warping and anti-windup techniques are adapted for the controller design. By using the proposed method, the phase margin and the control bandwidth are accurately achieved as required by controller designers in a practical frequency range. The proposed method is applied to a 2.5 kVA single-phase VDBR for Uninterruptible Power Supply (UPS) applications. From the simulation and the experimental results, the effectiveness of the proposed design method has been verified.

Unbalanced Characteristics of the Superconducting Fault Current Limiters with a Single Line-to-ground Fault (1선 지락사고에 대한 초전도한류기의 불평형 특성)

  • Choi, Hyo-Sang;Lee, Na-Young;Lee, Sang-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.851-855
    • /
    • 2005
  • We investigated the unbalanced characteristics of the superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased about 6 times of transport currents after the fault onset but was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unbalanced rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unbalanced rates of currents were noticeably improved within one cycle after the fault onset. We calculated the zero phase currents for a single line-to-ground fault using the balanced component analysis. The positive sequence resistance was reduced remarkably right after the fault onset but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase balanced state in about 60 ms after the fault onset at the three-phase system.