• 제목/요약/키워드: Single phase

검색결과 5,328건 처리시간 0.029초

비접지 계통에서 영상전류 위상을 이용한 고장표시 생성 알고리즘 (A Fault Indicator Generation Algorithm using Phase Angle of Zero-Sequence Current in Ungrounded System)

  • 임희택;임일형;최면송;이승재
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1141-1149
    • /
    • 2008
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. This paper proposed to a FI(Fault Indicator) generation algorithm in ungrounded system. The algorithm just using line-to-line voltage and zero-sequence current detects fault line, fault phase, fault section and FI(Fault Indicator) at terminal device, This paper also proposed to application plan for this algorithm. In the case study, the proposed algorithm has been testified in demo system by Matlab/Simulink simulations.

진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究) (A Study on Radiation Quality of the Diagnostic X-ray Equipments)

  • 박명환;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

유니폴라 구동회로를 이용한 단상 SRM의 속도 특성 측정 (The Speed Character Measurements of the Single Phase SRM by using the Unipolar driving curcuit)

  • 김용헌;이은웅;이종한;조연찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.887-888
    • /
    • 2006
  • Switched Reluctance Motor(SRM) is rotated by reluctance force generated between rotor pole and stator pole. So SRM must be switched by exciting current according to rotor position. but SRM takes the advantages of high speed driving and very simple structure. The single phase SRM can not be start by itself and torque ripple is generated more than multi-phase SRM. But mechanical structure and driver is simpler than multi-phase SRM. The single phase SRM driver is composed with the absolute encoder and DSP to control exciting section and current, and is supplied by constant voltage. So The paper is intend to measure the speed charactrer of double silent pole type SRM by using the unipolar driving curcuit.

  • PDF

송풍기 구동용 단상 SRM의 인덕턴스 해석 (The Analysis of the Inductance Profile in the Single Phase SRM for Blower)

  • 이종한;이은웅;김용헌;구태만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1025-1027
    • /
    • 2004
  • Recently, the Single phase SRM has been researched and developed in many appliances with various types. This paper presents a theoretical representation of the phase inductance of a single phase SRM, as function of position and current, taking into account the non-linearity of the magnetic circuit. The method is based on the Fourier series expansion. the theoretical expressions for the calculation of instantaneous phase inductance, flux linkage, coenergy and electromagnetic torque as a function of rotor position and winding currents are derived. And it is compared with the results of the finite element analysis.

  • PDF

전압형 PWM 단상 컨버터와 3상 인버터를 이용한 유도전동기의 운전 (Drive of induction motor using three-phase inverter and voltage type PWM single-phase converter)

  • 문상필;서기영;이현우;강욱중
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.18-24
    • /
    • 2001
  • 본 연구에서는 단상 PWM 컨버터와 3상 PWM 전압형 인버터 유도전동기 운전으로 나누 어져 있다. 단상 시스템의 교류 전원의 주파수에는 순시전력의 맥동성분을 가진다. 컨버터의 직류 맥동전압은 맥동성분을 발생시킨다. 결과적으로 인버터의 출력전압과 전류의 파형은 왜곡된다 시스템의 정상상태는 상태공간법으로 해석된다. 이러한 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 확인하였다.

  • PDF

EMTP-RV를 이용한 2차 아크 모델링 (Modelling of Secondary Arc Using EMTP-RV)

  • 오윤식;강성범;서훈철;김철환
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.937-943
    • /
    • 2012
  • Most of faults occurred in transmission lines are single-phase to ground faults and transient faults. Single-phase auto reclosing is an appropriate scheme to maintain the system stability and restore the system effectively when those faults are occurred. In single-phase auto reclosing scheme, the secondary arc is generated after faulted phase is tripped to eliminate the fault and it is sustained by the capacitive and inductive coupling to the healthy phases. It is important to reclose the faulted phase after fully extinction of secondary arc because of the damage applied to system. Therefore, it is necessary to research on the detection of secondary arc extinction to ensure high success rate of reclosing. In this step, firstly, the accurate modelling of secondary arc should be performed. In this paper, the modelling of secondary arc is performed by using EMTP-RV and the simulation results show that the implemented model is correct and effective.

Fast Single-Phase All Digital Phase-Locked Loop for Grid Synchronization under Distorted Grid Conditions

  • Zhang, Peiyong;Fang, Haixia;Li, Yike;Feng, Chenhui
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1523-1535
    • /
    • 2018
  • High-performance Phase-Locked Loops (PLLs) are critical for grid synchronization in grid-tied power electronic applications. In this paper, a new single-phase All Digital Phase-Locked Loop (ADPLL) is proposed. It features fast transient response and good robustness under distorted grid conditions. It is designed for Field Programmable Gate Array (FPGA) implementation. As a result, a high sampling frequency of 1MHz can be obtained. In addition, a new OSG is adopted to track the power frequency, improve the harmonic rejection and remove the dc offset. Unlike previous methods, it avoids extra feedback loop, which results in an enlarged system bandwidth, enhanced stability and improved dynamic performance. In this case, a new parameter optimization method with consideration of loop delay is employed to achieve a fast dynamic response and guarantee accuracy. The Phase Detector (PD) and Voltage Controlled Oscillator (VCO) are realized by a Coordinate Rotation Digital Computer (CORDIC) algorithm and a Direct Digital Synthesis (DDS) block, respectively. The whole PLL system is finally produced on a FPGA. A theoretical analysis and experiments under various distorted grid conditions, including voltage sag, phase jump, frequency step, harmonics distortion, dc offset and combined disturbances, are also presented to verify the fast dynamic response and good robustness of the ADPLL.

가상 2상 방식을 사용한 단상 PLL 알고리즘의 성능 비교 (Performance Comparison of Single-Phase PLL Algorithms Using Virtual 2-Phase Strategy)

  • 이용석;지준근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents a comparative study of single-phase PLL algorithms using virtual 2-phase strategy. Simulation and experimental results, including operation of the PLL structures introduced in reference papers, are presented to allow a performance comparison of the PLL algorithms.

  • PDF

IGBT를 이용한 단산 PWM정류기 병렬운전 (The Parallel Operation of Single Phase PWM Rectifier using IGBT)

  • 이현원;장성영;김연준;이광주;김남해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.122-125
    • /
    • 1999
  • The AC-to-DC single-phase PWM rectifier for traction applications using high power semiconductor, IGCT is made and tested. Parallel operation of two PWM converter is adopted for increasing capacity of converters. For reducing harmonics, the harmonic content is eliminated by the phase shift between two converters switching phase. The output voltage control is achieved by interns calculation without detecting the input current. The part of PLL used for controlling power factor is simply implemented by software.

  • PDF

디지털 PLL 제어의 특성 분석 (The Analysis of Characteristics for Digital PLL Control)

  • 김용균;최종우;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.548-553
    • /
    • 2003
  • The frequency and phase angle of the utility voltage are important in many industrial systems. this paper present a detailed analysis of single-phase digital PLL control for utility connected systems. and its performance under utility conditions with noise is discussed. The experimental results demonstrate phase tracking capability in the single-phase grid-connected operation.

  • PDF