• Title/Summary/Keyword: Single fracture

Search Result 654, Processing Time 0.025 seconds

Effect of adhesive application method on repair bond strength of composite

  • Hee Kyeong Oh;Dong Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.32.1-32.10
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of the application method of universal adhesives on the shear bond strength (SBS) of repaired composites, applied with different thicknesses. Materials and Methods: The 84 specimens (Filtek Z350 XT) were prepared, stored in distilled water for a week and thermocycled (5,000 cycles, 5℃ to 55℃). They were roughened using 400-grit sandpapers and etched with phosphoric acid. Then, specimens were equally divided into 2 groups; Single Bond Universal (SU) and Prime&Bond Universal (PB). Each group was subdivided into 3 subgroups according to application methods (n = 14); UC: 1 coat + uncuring, 1C: 1 coat + curing, 3C: 3 coats + curing. After storage of the repaired composite for 24 hours, specimens were subjected to the SBS test and the data were statistically analyzed by 2-way analysis of variance and independent t-tests. Specimens were examined with a stereomicroscope to analyze fracture mode and a scanning electron microscope to observe the interface. Results: Adhesive material was a significant factor (p = 0.001). Bond strengths with SU were higher than PB. The highest strength was obtained from the 1C group with SU. Bonding in multiple layers increased adhesive thicknesses, but there was no significant difference in SBS values (p = 0.255). Failure mode was predominantly cohesive in old composites. Conclusions: The application of an adequate bonding system plays an important role in repairing composite resin. SU showed higher SBS than PB and the additional layers increased the adhesive thickness without affecting SBS.

A study on the micromotion between the dental implant and superstructure (임플란트와 상부구조물 사이의 micromotion에 관한 연구)

  • Kim, Ji-Hye;Song, Kwang-Yeob;Jang, Tae-Yeob;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

Effect of Surface Treatment of Porcelain on Tensile Bond Strength (도재의 표면처리가 인장접착강도에 미치는 영향)

  • KIM, Shin-Geun;SUNG, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.301-307
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of surface treatment of porcelain on tensile bond strength. To accomplish this purpose, this study was carried out with 120 samples which were divided into 12 groups with each 10 samples, and the first group was not surface treated, groups 2 through 5 underwent single surface treatment, and groups 6 through 12 underwent compound surface treatment. The results were as follows : 1. In statistic, all the single surface-treated groups showed higher tensile bond strength than the non surface-treated group and the sandblasted group showed the highest tensile bond strength as $10.34{\pm}2.50MPa$. 2. All the compound surface-treated groups showed no noticeable difference in the tensile bond strength(9-11.5MPa). 3. In statistic, no significant difference was found between the sandblasted group and the compound surface-treated groups. 4. There was no fracture of porcelain while testing in this study. Above study demonstrated that compound surface treatment or sandblasing, if used single surface treatment, should be employed to guarantee successful clinical application.

  • PDF

The clinical study on 44 cases of patient with Thoracolumbar Compression Fracture (흉(胸)·요추(腰椎) 압박골절(壓迫骨折) 환자(患者)에 대한 임상적(臨床的) 고찰(考察))

  • Lim, Jeoung-Eun;Kim, Kee-Hyun;Hwang, Hyeon-Seo
    • Journal of Acupuncture Research
    • /
    • v.17 no.2
    • /
    • pp.41-51
    • /
    • 2000
  • Clinical observation was made on 44 cases of stable thoracolumbar compression fracture that were confirmed through simple x-ray and neurological examination. They were hospitalized and treated by acupuncture and moxibustion, bed rest, herb medicine and physical therapy. If necessary, patient was given an enema. The results obtained are as follows. 1. The patient distribution ratio, in regard to sex, was shown to be 1: 13.7 for males to females. In regard to age, it was shown that people in their 60's was the most predominant case, followed by people in their 70's, 80's, 50's and 40's, respectively. 2. In regard to contributing factors, it was observed that accidental falls were most frequent, followed by reasons unknown, repetitive lifting of heavy objects, overlaboring and bruise in that order. 3. In regard to duration of illness before treatment, it was found that treatment within 1 week was most predominant, followed by over 4 weeks, and 1-2 weeks, respectively. 4. With regard to the duration of hospitalization, hospitalization within 2 weeks was found to be most predominant, followed by 2-4 weeks. 5. In regard to the level of the affected vertebral body; The affected vertebral bodies distributed between T3 to L5 except for T7; T12 was found to be most predominant, followed in turn by L1 and L5. 6. In regard to the number of affected vertebral bodies, 2 was the most frequent followed by 1 and 3, in that order. The average of the number of affected vertebral bodies was observed to be 2.8 and single vertebral body compression fracture was shown to have no clinical and statistical difference as compared with multiple vertebral body compression fractures. 7. In regard to the grade of the seriousness of symptoms, it was found that Grade IV was most predominant, followed by Grade III. 8. With regard to signs at the first medical examination, low back pain was seen in the highest number, and followed in order by gait disturbance, flank pain, flexion-extension disturbance, disturbance of rotation to right or left, and bowel dysfunction. 9. Concerning the effect of treatment, good results were most predominantly seen, and 95.5% of total patients showed fair results. 10. The duration of admission treatment due to the grade of clinical symptoms was as follows; In the case of the Grade IV, it was observed that within 2 weeks was most predominant and for Grade III was 2-4 weeks. It was also found that the grade of clinical symptoms was not in proportion to the duration of admission treatment. 11. In regard to the result of treatment due to the grade of clinical symptoms; It was found that in the case of Grade IV, within 2 weeks was most predominant, and for Grade III, it was found to be 2-4 weeks. 12. Intestinal obstruction was shown in 50% of total patients; In the case of duration of constipation, more than 1 week was found to be most predominant, followed by 2 and 4 days respectively. 13. With regard to the treatment of intestinal obstruction, using acupuncture and moxibustion, herb - medicine and enema together were found to be most effective. 14. Intestinal obstruction was mostly seen in the case of Grade IV.

  • PDF

The Use and its Affecting Factors of patients aged 30 and over with single and multiple chronic diseases and their usage outpatient Korean medicine clinics - Based on the Ministry of Health and Welfare's 2011 Report on usage of Korean medicine - (30세 이상 한방의료기관 외래환자 중 비복합 및 복합만성질환자의 의료이용과 결정요인 - 2011년 한방의료이용 및 한약소비실태조사보고서(보건복지부)자료를 중심으로 -)

  • Yoon, Jinwon;Choi, Sungyong;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.95-107
    • /
    • 2015
  • Objective : To use and its affecting factors of patients' outpatient treatment that have single and multiple chronic illnesses Method : We used the 2011 study by the Ministry of Health and Welfare, "Report on Usage and Consumption of Korean Medicine." This report was conducted on outpatients and inpatients that visited Korean traditional medicine, from August 25th, 2011, to September 30th, 2011. Our research was based on 1729 patients with chronic diseases aged 30 and over who received outpatient treatment during the last three months. Results : There were 1365 patients with non-complex chronic diseases, while there were 364 patients with complex chronis diseases. Patients had 1 - 8 chronic diseases, and the average number (standard deviation) was 1.26 (0.59). There were statistically significant differences by sex(P<0.0001), age(p=0.0045), marriage (p=0.0060), education level(p<0.0001), income level(P=0.0063), and types of health insurance(p=0.0023). The diseases most common among patients with non-complex chronic diseases were: low back pain, arthritis, gastrointestinal disorder, frozen shoulder, side effects from motor accidents, high blood pressure, fracture, stroke, diabetes, cancer, atopic dermatitis, and asthma. The diseases most common among patients with non-complex chronic diseases were: arthritis+low back pain, low back pain+gastrointestinal disorder, low back pain+side effects from motor accidents, low back pain+frozen shoulder, arthritis+gastrointestinal disease, gastrointestinal disease+frozen shoulder, arthritis+low back pain+gastrointestinal disease, high blood pressure+arthritis, arthritis+low back pain+frozen shoulder, arthritis+fracture, and arthritis+side effects from motor accidents. There were statistically significant differences among the usage of medical clinics by: frequently used clinic (p<0.0001), number of treatment (p<0.0001), the cost of outpatient treatment (p=0.0073), the satisfaction rate (p=0.0171), whether the clinic is the preferred clinic (p=0.0040). In model 1, men than women, people who had local benefits instead of type 1 medical aid, and patients with complex chronic diseases were more likely to use Korean medical clinics. In model 2, men than women, people who had local benefits than people with types 1 and 2 medical aids, people who went to pharmacies and Korean medicine pharmacies than people who went to hospitals, people who went to get treatment 1-10 times than people who visited 11-20 times and more than 41 times, and people who spent less than ten thousand Korean won than people who spent 1 to 2 million Korean won, and people without complex chronic diseases were more likely to use Korean medical treatment. Conclusion : There were differences in sociodemographic characteristics and the usage of medical clinics between patients with non-complex chronic diseases and patients with complex chronic diseases. Among patients with complex chronic diseases, women, patients with types 1 and 2 medical aid, patients who used Korean medical clinics, patients who were treated 11-20 times and more than 41 times, and patients who spent 1 million to 2 million Korean won on outpatient treatment used less treatment than patients with non-complex chronic diseases. However, patients with complex chronic diseases used pharmacies and Korean medicine pharmacies more.

A Study on Tensile Restraint Crack Critical Stress Characteristcs of Gravity-Wet-Type Underwater Welded Joints (중력식 습식 수중용접부의 인강구속균열 임계응력 특성에 관한 연구)

  • O, Se-Gyu;Gang, Mun-Ho;Han, Sang-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.61-65
    • /
    • 1987
  • In this study, the characteristics of TRC (tensile restraint crack) critical stress in the gravity type underwater wet welding process and in the in-air welding have been investigated for Y, y and 45$^{\circ}$r grooves using the KR Grade A-3 steel plates and the E4303 covered electrodes. The following results were obtained: (1) In the TRC tests, the initial critical stress of Y groove is higher than those of the 45$^{\circ}$r single bebel grooves in both in-air and underwater weldings, and the cold fracture sensitivity is higher in the underwater welding than in the in-air welding. (2) The hardness of underwater weld metal is the highest in heat affected zone is about Hk 365 in the in-air weld but Hk 670 in the underwater weld which is higher for cooling speed is more rapid, resulting in the lower critical stress by increase of fracture sensitivity. (3) The diffusible hydrogen quantity for 48 hours is about 18cc/100g-weld-metal in the in-air welding but 48cc/100g-weld-metal in the underwater welding. So that, in the case of underwater welding the diffusible hydrogen penetrates about 3 times more than that in the in-air welding.

  • PDF

A Study on Tensile Restraint Crack Critical Stress Characteristcs of Gravity-Wet-Type Underwater Welded Joints (중력식 습식 수중용접부의 인강구속균열 임계응력 특성에 관한 연구)

  • Sae Kyoo Oh;Moon Ho Kang;Sang Deok Han
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.15-15
    • /
    • 1987
  • In this study, the characteristics of TRC (tensile restraint crack) critical stress in the gravity type underwater wet welding process and in the in-air welding have been investigated for Y, y and 45°r grooves using the KR Grade A-3 steel plates and the E4303 covered electrodes. The following results were obtained: (1) In the TRC tests, the initial critical stress of Y groove is higher than those of the 45°r single bebel grooves in both in-air and underwater weldings, and the cold fracture sensitivity is higher in the underwater welding than in the in-air welding. (2) The hardness of underwater weld metal is the highest in heat affected zone is about Hk 365 in the in-air weld but Hk 670 in the underwater weld which is higher for cooling speed is more rapid, resulting in the lower critical stress by increase of fracture sensitivity. (3) The diffusible hydrogen quantity for 48 hours is about 18cc/100g-weld-metal in the in-air welding but 48cc/100g-weld-metal in the underwater welding. So that, in the case of underwater welding the diffusible hydrogen penetrates about 3 times more than that in the in-air welding.

Combined Effects of Sustained Load and Temperature on Pull-off Strength and Creep Response between CFRP Sheet and Concrete Using Digital Image Processing (디지털 이미지 분석을 통한 지속 하중과 온도의 복합 환경이 CFRP 쉬트와 콘크리트의 부착강도 및 크리프 거동에 미치는 영향 분석)

  • Jeong, Yo-Seok;Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.535-544
    • /
    • 2016
  • This paper aims at examining the effects of sustained load and elevated temperature on the time-dependent deformation of a carbon fiber reinforced polymer (CFRP) sheets bonded to concrete as well as the pull-off strength of single-lap shear specimens after the sustained loading period using digital images. Elevated temperature during the sustained loading period resulted in increased slip of the CFRP composites, whereas increased curing time of the polymer resin prior to the sustained loading period resulted in reduced slip. Pull-off tests conducted after sustained loading period showed that the presence of sustained load resulted in increased pull-off strength and interfacial fracture energy. This beneficial effect decreased with increased creep duration. Based on analysis of digital images, results on strain distributions and fracture surfaces indicated that stress relaxation of the epoxy occurred in the 30 mm closest to the loaded end of the CFRP composites during sustained loading, which increased the pull-off strength provided the failure locus remained mostly in the concrete. For longer sustained loading duration, the failure mode of concrete-CFRP bond region can change from a cohesive failure in the concrete to an interfacial failure along the concrete/epoxy interface, which diminished part of the strength increase due to the stress relaxation of the adhesive.

A STUDY ON THE TENSILE STRENGTH OF REINFORCED VENEERING COMPOSITE RESINS FOR CROWN (강화형 치관용 복합레진의 인장강도에 관한 연구)

  • Ahn, Seung-Geun;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.226-241
    • /
    • 2000
  • Recently a new generation of crown and bridge veneering resins containing submicron glass fillers was introduced. These ultrasmall particle hybrid composite materials distinguish themselves, compared with conventional microfill crown and bridge resins, through improved mechanical properties. It is claimed that these composites are suitable for metal free crowns and even bridges using fiber reinforcement. The purpose of this study was to evaluate the effect of thermal cycling on the tensile strength of the following veneering composites: Artglass(Heraeus Kulzer Co., Wehrheim, Germany), Estonia(Kuraray Co.. Japan), Sculpture(Jeneric Pentron Co., Wallingford, U.S.A.), and Targis(Ivoclar Co., Schaan Liechenstein). According to manufacturer's instructions, rectangular tensile test specimens measuring $1.5{\times}2.0{\times}4.5mm$ were made using a teflon mold. Whole specimens were divided into two groups. One group was dried in a desiccator at $25^{\circ}C$ for 10 days, and another group was subjected to thermal cycling($10,000{\times}$) in water($5/55^{\circ}C$). All test specimens were placed in a universal testing machine and loaded until fracture with a crosshead speed of 0.5mm/min. Weibull analysis and Tukey's test were used to analyze the data. The fracture surfaces of specimens were observed in SEM and the aliphatic C=C absorbance peak of Estenia and Targis resin was analyzed using Fourier transform infrared(FTIR) spectroscopy. Within the limitations imposed in this study, the following conclusions can be drawn: 1. Both in drying condition and thermal cycling condition, the highest tensile strength was observed in Estenia testing group(p<0.05). 2. The strength data were at to single-mode Weibull distribution, and the Weibull modulus of all veneering composite resin specimens increased after thermal cycling treatment. 3. After thermal cycling test, the highest tensile strength was observed in the Estenia group, and the lowest value was observed in the Targis group. The tensile strength values showed the significant differences between each group(p<0.05) 4. The aliphatic C=C absorbance peak of Estonia and Targis resin was decreased after light curing, and there was no distinct change after thermal cycling.

  • PDF

A Making of Aesthetic Dental restorations with Nano Hybrid Ceramic material by CAD/CAM System (치과 CAD/CAM용 Nano Hybrid Ceranic 소재를 이용한 심미 치과보철물의 제작)

  • Choi, Beom-jin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.98-108
    • /
    • 2016
  • In recent days, perhaps the biggest driver in new material development is the desire to improve restorations esthetics compared to the traditional metal substructure based ceramics or all-ceramic restorations. Each material type performs differently regarding strength, toughness, effectiveness of machining and the final preparation of the material prior to placement. For example, glass ceramics are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long time sintering procedure which excludes its use for fast chair side production. Hybrid ceramic material developed for CAD/CAM system is contained improved nano ceramic elements. This new material, called a Resin Nano Hybrid Ceramic is unique in durability of function and aesthetic base compositions. The new nano-hybrid ceramic material is not a composite resin. It is also not a pure ceramic. The material is a mixture of both and consists of nano-ceramic fillers. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined by chair side or in a dental lab side, could be an useful restorative option.