• Title/Summary/Keyword: Single fracture

Search Result 654, Processing Time 0.024 seconds

A Numerical Study on Characteristics of Solute Transport in a Rough Single Fracture with Spatial Correlation Length and Effect of Effective Normal Stress (공간적 상관길이와 유효수직응력의 효과에 따른 거친 단일 균열내의 용질이동특성에 관한 수치적 연구)

  • Jeong, Woochang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.5-14
    • /
    • 2009
  • This study is to analyze numerically the spatial behaviors of the solute transport in a spatially correlated variable-aperture fracture under the effective normal stress conditions. Numerical results show that the solute transport in a fracture is strongly affected by the spatial correlation length of apertures and applied effective normal stress. According to increasing spatial correlation length, the mean residence time of solute is decreased and the tortuosity and Peclet number (is a dimensionless number relating the rate of advection of a flow to its rate of diffusion) is also decreased. These results mean that the geometry of the aperture distribution is favorable to the solute transport as the spatial correlation length is increased. However, according to the applied effective normal stress is increased, the mean residence time and tortuosity have a tendency to increase but the Peclet number is decreased. The main reason that the Peclet number is decreased, is that the solute is displaced by one or two channels with relatively higher local flow rate due to the increment of contact areas by increasing effective normal stress. Moreover, based on numerical results of the solute transport in this study, the exponential-type correlation formulae between the mean residence time and the effective normal stress are proposed.

  • PDF

A decade of treating traumatic sternal fractures in a single-center experience in Korea: a retrospective cohort study

  • Na Hyeon Lee;Seon Hee Kim;Jae Hun Kim;Ho Hyun Kim;Sang Bong Lee;Chan Ik Park;Gil Hwan Kim;Dong Yeon Ryu;Sun Hyun Kim
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.362-368
    • /
    • 2023
  • Purpose: Clinical reports on treatment outcomes of sternal fractures are lacking. This study details the clinical features, treatment approaches, and outcomes related to traumatic sternal fractures over a 10-year period at a single institution. Methods: A retrospective cohort study was conducted of patients admitted to a regional trauma center between January 2012 and December 2021. Among 7,918 patients with chest injuries, 266 were diagnosed with traumatic sternal fractures. Patient data were collected, including demographics, injury mechanisms, severity, associated injuries, sternal fracture characteristics, hospital stay duration, mortality, respiratory complications, and surgical details. Surgical indications encompassed emergency cases involving intrathoracic injuries, unstable fractures, severe dislocations, flail chest, malunion, and persistent high-grade pain. Results: Of 266 patients with traumatic sternal fractures, 260 were included; 98 underwent surgical treatment for sternal fractures, while 162 were managed conservatively. Surgical indications ranged from intrathoracic organ or blood vessel injuries necessitating thoracotomy to unstable fractures with severe dislocations. Factors influencing surgical treatment included flail motion and rib fracture. The median length of intensive care unit stay was 5.4 days (interquartile range [IQR], 1.5-18.0 days) for the nonsurgery group and 8.6 days (IQR, 3.3-23.6 days) for the surgery group. The median length of hospital stay was 20.9 days (IQR, 9.3-48.3 days) for the nonsurgery group and 27.5 days (IQR, 17.0 to 58.0 days) for the surgery group. The between-group differences were not statistically significant. Surgical interventions were successful, with stable bone union and minimal complications. Flail motion in the presence of rib fracture was a crucial consideration for surgical intervention. Conclusions: Surgical treatment recommendations for sternal fractures vary based on flail chest presence, displacement degree, and rib fracture. Surgery is recommended for patients with offset-type sternal fractures with rib and segmental sternal fractures. Surgical intervention led to stable bone union and minimal complications.

Elastic Work Factor of CLS Specimen and Determination of $G_c$ for Graphite/Peek Composites by Using the Elastic Work Factor (CLS 시편의 탄성일인자 유도 및 이를 적용한 열가소성 Graphite/Peek 복합재의 파괴인성 $G_c$ 측정)

  • Lee, Gyeong-Yeop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2792-2799
    • /
    • 1996
  • It was shown in the previous study that the numerically derived elastic work factor for CLS specimen was independent of fiber direction for a unidirectional case. Also, it was proposed the elastic work factor could be used to determine energy release rate from a single test record. In the present study, elastic work factor was derived from a simple beam theory to investigate its dependence on material property and geometric condition. Also, the elastic work factor of CLS specimen was applied experimentally to determine critical energy release rate in order to prove its validity determining critical energy release rate from a single specimen. For this purpose, critical energy release rate determined using the elastic work factor was compared with that determined by the compliance method. The results showed that while elastic work factor is affected by $t_2/t_1$ and $L_2/L_1$ it is independent of fiber angle for a unidirectional case. It was also found that critical energy release rates determined by both methods are comparable each other, thus elastic work factor approach can be used to determine energy release rate from a single test specimen.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

The Forming Limit of Flange in the Radial Extrusion (레이디얼 압출에서 플랜지의 성형한계)

  • 고병두;장동환;최호준;임중연;황병복
    • Transactions of Materials Processing
    • /
    • v.12 no.3
    • /
    • pp.228-235
    • /
    • 2003
  • In this paper, the workability of flange in the radial extrusion is analyzed in terms of the deformation pattern, the punch load and the forming limit by using simulation and experiment. A single action pressing is applied to both simulation and experiment. The analysis in this study is focused on the transient extrusion into the gap in radial direction with various gap heights and die corner radius. Based on the surface strains where surface cracking occurs, the forming patterns and strain-fracture relationships in producing radially extruded flange are obtained.

Fractographic Studies of Impact Damage in Single Crystal Sapphire (충격에 의한 단결정 Sapphire의 파면 조직에 관한 연구)

  • 김종희
    • Journal of the Korean Ceramic Society
    • /
    • v.14 no.1
    • /
    • pp.19-24
    • /
    • 1977
  • 상온에서 단결정 Sapphire가 충격에 의해서 파괴될 때에 수반되는 미세 조직변화에 대하여 관찰하였다. 파괴된 시편을 광학현미경으로 조사한 결과 cleavage는 주로 rhombohedral plane에서 일어나고 있음을 알았다. 그러나 관찰시료 파면의 양상을 박막(replica)으로 만들어 투과형 전자현미경으로 관찰한 결과로는 국부적으로 소성변화가 일어나고 있음을 알 수 있었다. 이러한 국부적인 소성변화는 crack의 진행을 저해하거나 또는 진로를 변경 시켜주므로 보다 높은 fracture energy를 유발시키는 원인이 됨을 알 수 있다.

  • PDF

A Study on the Fatigue Fracture Behavior of Heat Cycle of Welded Dissimilar (이종금속 용접재의 열 사이클에 따른 피로파괴 거동에 관한 연구)

  • 신근하;김진덕
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 1993
  • It is very difficult to find not only optimized welding condition but also fatigue characteristics of the dissimilar weld. In this study. Low carbon steel (SS41) and austenitic stainless steel (STS304) were welded by GTAW welding with STS309 stainless wire rod and Single Edge Notch specimens were used for the examination of fatigue behavior on welding heat cycle. The fatigue crack growth rate in HAZ of SS41 was the highest. The second was in STS304 bond line and the lowest was in HAS of STS304.

  • PDF

Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy (유방암 절제술 후 방사선치료를 시행한 환자의 골스캔에서 보이는 방사전 유발 늑골골절)

  • Kim, Hae-Won;Won, Kyoung-Sook;Zeon, Seok-Kil;Kim, Jin-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.287-293
    • /
    • 2009
  • Purpose: This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Materials and Methods: Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest a findings of rib fracture were analyzed. Results: The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p = 0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p =0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest a, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p = 0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p = 0.001). Conclusion: Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.

The Preparation of $Pb(Zr_{0.52} Ti_{0.48})O_3$ Powders by a Chemical Method (화합물 침전법에 의한 $Pb(Zr_{0.52} Ti_{0.48})O_3$ 분말제조에 관한 연구)

  • 신동우;오근호;이종근
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.6
    • /
    • pp.37-41
    • /
    • 1985
  • Several $Al_2O_3$-based polycrystalline which had different dopant ratio in the range of 0.5mol% were prepared by doping pure $Cr_2O_3$, $ZrO_2$, $HfO_3$ Single crystalline which had same composition with above polycrystalline were made by means of floating zone method. This study examined the role of each dopant for enhancing the mefchanical properties of $Al_2O_3$-based Ceramics. Optical micrographs $({\times}200)$ of $Al_2O_3-Cr_2O_3$ single crystal showing not only radial crack (rc) on the specimen surface but median crack (mc) and lateral crack (lc) under surface at the edge of indentation mark. Fracture toughness of $Al_2O_3$-based Ceramics was increased with $ZrO_2$ content. Alloying effect of $Cr_2O_3$ contributed to the hardness of $Al_2O_3$ based ceramics.

  • PDF