• 제목/요약/키워드: Single fracture

검색결과 654건 처리시간 0.026초

Interdisciplinary rehabilitation of a root-fractured maxillary central incisor: A 12-year follow-up case report

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ciocci, Maurizio;Checchi, Luigi
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.217-225
    • /
    • 2014
  • Single-tooth implantation has become a common treatment solution for replacement of a root-fractured maxillary incisor in adults, but the long-term esthetic results can be unfavorable due to progressive marginal bone loss, resulting in gingival recession. In this case report, a maxillary central incisor with a root fracture in its apical one-third was orthodontically extruded and extracted in a 21-year-old female. Implant surgery was performed after a 3-month healing period, and the final crown was placed about 12 months after extraction. After 12 years, favorable osseous and gingival architectures were visible with adequate bone height and thickness at the buccal cortical plate, and no gingival recession was seen around the implant-supported crown. Although modern dentistry has been shifting toward simplified, clinical procedures and shorter treatment times, both general dentists and orthodontists should be aware of the possible long-term esthetic advantages of orthodontic extrusion of hopelessly fractured teeth for highly esthetically demanding areas and should educate and motivate patients regarding the choice of this treatment solution, if necessary.

유한평판 및 T-joint 필렛 용접부에 있어서 3차원 표면균열의 피로 파괴거동에 관한 실험적 연구 (An Experimental Study on Fatigue Fracture Behaviour of Surface Crack in Finite Plates and Fillet Welded T-joint)

  • 한문식;김재동;이호섭
    • 대한조선학회논문집
    • /
    • 제28권2호
    • /
    • pp.275-284
    • /
    • 1991
  • 최근 압력용기, 고압배관, LNG Tank 및 선체등의 구조물 파괴에 대한 안전성을 보증하기 위하여, 구조부재의 표면결함에 대한 균열성장 거동을 파악하는 것이 중요한 과제중에 하나라고 인식되어지고 있다. 본 연구에서는 단일 및 복수표면 결함의 피로균열 성장을 바탕으로 표면에서 관통되기까지의 균열성장 수명의 추정등 실질적이고 일반적인 문제들을 해석할려고 시도하였다. 또한, 복수균열 문제에 적용하기 위하여 복수 언더컷의 합체진전현상을 검토하였으며 단일 언더컷과 복수 언더컷의 전파특성이 유사함을 밝혔다.

  • PDF

Experimental study on seepage characteristics of large size rock specimens under three-dimensional stress

  • Sun, Wenbin;Xue, Yanchao;Yin, Liming;Zhang, Junming
    • Geomechanics and Engineering
    • /
    • 제18권6호
    • /
    • pp.567-574
    • /
    • 2019
  • In order to study the effect of stress and water pressure on the permeability of fractured rock mass under three-dimensional stress conditions, a single fracture triaxial stress-seepage coupling model was established; By using the stress-seepage coupling true triaxial test system, large-scale rock specimens were taken as the research object to carry out the coupling test of stress and seepage, the fitting formula of permeability coefficient was obtained. The influence of three-dimensional stress and water pressure on the permeability coefficient of fractured rock mass was discussed. The results show that the three-dimensional stress and water pressure have a significant effect on the fracture permeability coefficient, showing a negative exponential relationship. Under certain water pressure conditions, the permeability coefficient decreases with the increase of the three-dimensional stress, and the normal principal stress plays a dominant role in the permeability. Under certain stress conditions, the permeability coefficient increases when the water pressure increases. Further analysis shows that when the gob floor rock mass is changed from high stress to unloading state, the seepage characteristics of the cracked channels will be evidently strengthened.

지르코니아 프레임워크를 이용한 시멘트 유지형 임플란트-지지 단일 크라운과 연결 크라운의 보철적 합병증 (Technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks)

  • 유상춘;배정윤
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.26-31
    • /
    • 2017
  • 목적: 지르코니아 프레임워크를 이용한 시멘트 유지형 임플란트-지지 단일 크라운과 연결 크라운의 성공률과 보철적 합병증을 임상적으로 평가하는 것이다. 대상 및 방법: 67명의 환자에서 75개 수복물(단일 51개, 연결 24개)을 지르코니아 프레임워크를 이용한 시멘트 유지형 임플란트-지지 단일 크라운 혹은 연결 크라운으로 수복했다. 모든 수복물은 임시 시멘트로 합착했다. 보철적 합병증과 성공률을 조사하고, 나이, 성별, 보철물의 위치, 대합치, 보철물의 유형이 보철적 합병증에 미치는 영향을 평가했다. 결과:평균 22.2개월의 관찰 결과, 최종 누적 성공률은 66.9 (73.2 - 60.6)%였다. 유지 상실이 16개 보철물(단일 14개, 연결 2개)에서 나타났고, 지대주 나사 풀림과 비니어 도재 파절은 단일 크라운에서만 각각 2개의 보철물에서 나타났다. 단일 크라운과 연결 크라운에 대한 Kaplan-Meier 생존분석 결과, 최종 누적 성공률은 각각 58.9 (66.6 - 51.2)%, 87.5 (96.1 - 78.9)%를 보여 통계적으로 유의한 차이가 있었지만, 다른 고려 요인들은 보철적 합병증에 통계적으로 유의성이 없었다. 결론: 보철적 합병증은 유지 상실이 가장 많았고, 지대주 나사 풀림 및 비니어 도재 파절은 단일 크라운에서만 비교적 적게 관찰되었다. 나이, 성별, 보철물의 위치, 대합치에 따른 보철적 합병증에 미치는 영향은 유의한 차이가 없었지만, 상부 보철물을 연결 크라운으로 제작했을 때, 단일 크라운으로 제작한 경우보다 높은 성공률을 보였다.

수압파쇄 설계를 위한 수치해석기법의 증명 -해석식과의 비교를 중심으로 - (Verification of Numerical Technique for Hydraulic Fracturing Stimulation - by Comparison with Analytical Solutions -)

  • 심영종
    • 한국지반환경공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.65-71
    • /
    • 2009
  • 수압파쇄기술은 가스나 석유, 지열 등 자원추출을 하기 위해 다양한 분야에서 전세계적으로 응용되고 있는 기술이다. 이러한 수압파쇄 작업 시 복수의 균열이 필수적으로 발생하여 균열간 기계적인 상호작용을 유발하는데 이러한 상호작용은 수압파쇄시 얻어질 수 있는 결과(균열 폭, 균열 길이, 보어홀 내 압력)에 큰 영향을 끼치게 된다. 수치해석기법인 경계병치법은 이러한 균열간의 역학적 상호작용을 고려하는데 유효한 수치해석적 기법으로 개발이 되고 있으나 응력확대계수를 계산하는 해석식과의 비교 등을 통한 검증이 필요하다. 이를 위해 무한평면에 일축 인장 응력과 전단응력이 작용하는 단일균열의 경우 및 임의의 두 균열이 존재하는 경우의 응력확대계수 및 균열폭 해석식과 본 수치해석기법을 통해 얻은 값을 비교하였다. 그 결과, 본 연구에서 제시한 경계병치법은 해석식과 상당히 근접한 결과를 나타내어, 균열간의 기계적인 상호작용을 고려하는데 유효함을 검증하였으며, 추후 수압파쇄 시 설계에 필요한 균열폭 등의 변수를 계산하는데 사용할 수 있음을 나타내었다.

  • PDF

Micromechanical 시험법과 AE를 이용한 PVDF 함침 고분자 복합재료의 계면손상감지능 및 비파괴적 평가 연구 (Nondestructive Evaluation and Interfacial Damage Sensing of PVDF embedded Polymer Composites using Micromechanical Techniques and Acoustic Emission)

  • Kong, Jin-Woo;Park, Joung-Man;Kim, Ki-Bok;Yoon, Dong-Jin
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.216-219
    • /
    • 2002
  • Conventional piezoelectric lead-zirconate-titanate (PZT) senor has high sensitivity, but it is very brittle. Recently polymer films such as polyvinylidene fluoride (PVDF) have been used use as a sensor. The advantages of PVDF are the flexibility and mechanical toughness. Simple process and possible several shapes are also additional advantages. PVDF sensor can be directly embedded and attached to a structure. In this study, PVDF sensor was embedded in single glass fiber/epoxy composites whereas PZT sensor with AE was attached to single fiber composites (SFC). Piezoelectric sensor responds to interfacial damage of SFC. The signals measured by PVDF sensor were compared to PZT sensor. PZT sensor detected the signals of fiber fracture, matrix crack, interfacial debonding and even sensor delamination, whereas PVDF sensor only detected fiber fracture signals so far, because PZT sensor is much more sensitive than current PVDF sensor. Wave voltage of fiber fracture measured by PVDF sensor was lower than that of PZT sensor, but the results of fast Fourier transform (FFT) analysis were same. Wave velocity using two PZT sensors was also studied to know the internal and surface damage effect of epoxy specimens.

  • PDF

단정 주입시험 결과를 이용한 단열암반의 수리전도도 분석 (Estimation of Conductivity Tensor of Fractured Rocks from Single-hole Packer test)

  • 장근무;이은용;김창락;이찬구;김현주
    • 지질공학
    • /
    • 제10권1호
    • /
    • pp.13-25
    • /
    • 2000
  • 단열암반의 수리전도도 텐서를 계산하고 이방성에 대한 정량적인 평가를 수행하기 위해서 단열의 수리적, 기하학적 통계 특성에 근거하여 3차원 단열연결망 모델을 구성하였다. 현장에서 수행된 단정주입시험의 수치모델링을 통해 계산된 수리전도도는 현장시험 결과와 비교적 잘 일치하였다. 따라서 구성된 3차원 단열 연결망 모델이 해석대상 암반의 수리 특성을 구현할 수 있음을 확인하였다. 대상암반의 대표요소체적 규모에서 계산된 블록 수리전도도는 단정주입시험에서 구한 수리전도도의 산술과 조화 평균 사이의 값이며, 2차원 수평단면상에서 남-북 방향의 수리전도도는 동-서 방향에 비해서 약 1.4 배로써 이방성은 크지 않았다. 블록 수리전도도와 단정 주입시험 모델링을 통해 구한 수리전도도의 상관성은 낮게 나타났다. 이는 단정 주입시험 모델링을 통한 암반의 수리전도도는 시추공의 패커구간과 교차하는 단열의 수와 투수량계수에 큰 영향을 받기 때문인 것으로 분석된다.

  • PDF

Correlation between the Time to Surgery and That to Recovery from Postoperative Diplopia Based on a Single-Center, Retrospective Experience: A Case Series of 11 Patients

  • Kim, Nam Hoon;Kang, Seok Joo
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.486-492
    • /
    • 2014
  • Background We conducted this study to identify the correlation between the time to surgery and that to recovery from postoperative diplopia. Methods In the current single-center, retrospective study, we enrolled a total of 11 patients (n=11) who were diagnosed with white-eyed blowout fracture and underwent surgical operation at our institution between January 2009 and January 2013. To identify the correlation between the time to surgery and that to recovery from postoperative diplopia, we divided our patients into the three groups: the group A (time to surgery, <2 days) (n=4), the group B (time to surgery, 3-7 days) (n=4) and the group C (n=3) (time to surgery, 8-60 days). Then, we compared such variables as sex, age, signs of soft tissue injury, preoperative nausea/vomiting, the degree of preoperative diplopia and the side of the fracture on computed tomography scans between the three groups. Results In our series, mean age at the onset of trauma was nine years (range, 5-16 years); the mean time to surgery was 30 days (range, 2-60 days); and the mean follow-up period was one year (range, 6 months-2 years). Our results showed that the time to recovery was shorter in the patients with a shorter time to surgery. Conclusions We found that the degree of recovery from impaired ocular motility and diplopia was the highest in the patients undergoing surgical operations within 48 hours of the onset of trauma with the reconstruction of the fracture sites using implant materials.

구속효과를 고려한 9% Ni강 균열의 파괴거동 해석에 관한 연구 (A Study on the Fracture Behavior of a Crack in 9% Ni Steel Considering Constraint Effect)

  • 김영균;윤인수;김재훈
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.14-21
    • /
    • 2021
  • -162℃ 초저온 상태의 LNG를 저장하는 저장탱크의 내조는 균열과 같은 결함에 대한 구조 건전성 평가가 필요하다. 전통적인 파괴역학 관점에서는 응력확대계수 K, J-적분 그리고 CTOD를 이용한 단일 매개변수 평가가 주로 수행되어왔다. 그러나 실제 구조에서 발생되는 균열선단은 구조물의 크기, 시편형상 그리고 인장과 굽힘과 같은 하중의 형태에 따라 구속효과의 차이로 인한 영향이 발생하게 된다. 단일 매개변수 파괴역학을 보완하기 위해 다양한 시도가 있었고, 대표적으로 Q-응력법이 있다. 본 논문에서는 비선형 탄성영역의 균열선단 응력장 평가에 적합한 J적분에 Q응력을 유도하여 2 매개변수 접근법을 사용하고자 한다. SENB 시편의 균열비 0.1~0.7 그리고 광폭시편 균열비 0.2~0.6에 시편 균열선단의 응력을 J-Q 평가법을 이용하여 구속효과를 정량적으로 평가 하였다.

Safety and Efficacy of Bone Cement (Spinofill®) for Verte-broplasty in Patients with Osteoporotic Compression Fracture : A Preliminary Prospective Study

  • Park, Han Byeol;Son, Seong;Jung, Jong Myung;Lee, Sang Gu;Yoo, Byung Rhae
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권5호
    • /
    • pp.730-740
    • /
    • 2022
  • Objective : Although several commercialized bone cements are used during percutaneous vertebroplasty (PVP) for patients with osteoporotic vertebral compression fracture (OVCF), there are no reports using domestic products from South Korea. In this study, we investigated the safety and efficacy of Spinofill® (Injecta Inc., Gunpo, Korea), a new polymethyl methacrylate product. Methods : A prospective, single-center, and single-arm clinical trial of 30 participants who underwent PVP using Spinofill® for painful thoracolumbar OVCF was performed with 6-months follow-up. Clinical and surgical outcomes included the Visual analog scale (VAS), Korean-Oswestry disability index (K-ODI), and Odom's criteria, complication rate, and recurrence rate. Radiological outcomes were evaluated by measuring the findings of postoperative computed tomography and simple radiograph. Results : The pain of VAS (from 8.95±1.05 to 4.65±2.06, p<0.001) and the life quality based on K-ODI (from 33.95±5.84 to 25.65±4.79, p<0.001) improved significantly, and successful patient satisfaction were achieved in 20 patients (66.7%) 1 day after surgery. These immediate improvements were maintained or more improved during the follow-up. There was no surgery- or product-related complications, but OVCF recurred in two patients (6.7%). Favorable cement interdigitation was reported in 24 patients (80.0%), and extra-vertebral cement leakage was reported in 13 patients (43.0%). The mean vertebral height ratio (from 60.49%±21.97% to 80.07%±13.16%, p<0.001) and segmental kyphotic angle (from 11.46°±8.50° to 7.79°±6.08°, p=0.002) improved one day after surgery. However, these short-term radiological findings somewhat regressed at the end. Conclusion : The overall outcomes of PVP using Spinofill® were as favorable as those of other conventionally used products.