• 제목/요약/키워드: Single crowns restoration

검색결과 27건 처리시간 0.022초

단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석 (THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS)

  • 권주홍;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.

Open-face Stainless Steel Crown을 이용한 유전치의 치료에 대한 증례보고 (A CASE REPORT ON PRIMARY INCISOR TREATMENT USING OPEN-FACE STAINLESS STEEL CROWN)

  • 김종민;최형준;이제호;최병재
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.781-787
    • /
    • 1997
  • In spite of the improvements of the techniques in the field of preventive dentistry, many children still present with extensive destruction of primary anterior teeth. Not only the practioner must consider the pulp state of the primary incisor, but also restore the form, function and esthetics of the tooth. Restorative treatment of primary incisor tooth requires durability, retention and esthetics. Stainless steel crowns used in restoring primary anterior teeth is retentive and durable in comparison with the composite resin, celluloid crown. But they are not esthetic. To enhance the esthetics of the anterior stainless steel crown without reducing its superior retention, an open-face stainless steel crown has been suggested. Several authors have suggested cutting away the labial portion of the stainless steel crown and placing the composite resin in that area. By following this technique, the practioner can prepare a retentive, durable, and esthetic restoration for primary teeth which have suffered from extensive loss of teeth structure. In addition, the single missing primary anterior teeth can be successfully restored by soldering the stainless steel crown together. Open-face stainless steel crown is indicated in the areas of large interproximal lesions involving incisal edge, crown fracture with pulp exposure and congenital malformation of the teeth. By this technique, the practioner can restore primary anterior teeth successfully regardless of the amount of remaining tooth structure, bruxism habit and presence of attrition. In this case, rampant caries with extensive loss of tooth structure and single missing of primary anterior tooth hart been successfully treated with open-face stainless steel crown.

  • PDF

Survival of 352 titanium implants placed in 181 patients: a 4-year multicenter field study

  • Shin, Seung-Il;Yun, Jeong-Ho;Kim, Sung-Geun;Park, Byoungkyou;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • 제44권1호
    • /
    • pp.8-12
    • /
    • 2014
  • Purpose: The aim of this retrospective chart review was to evaluate the four-year survival rate of a titanium implant system. Methods: A total of 352 sand-blasted, thermally acid-etched titanium implants were inserted into 181 partially or completely edentulous patients. Their cumulative survival rate was evaluated retrospectively. Associated factors, such as the implant distribution and treatment type were included in the evaluation. Results: The implants were equally distributed between the maxilla (52.3%) and the mandible (47.7%). 48 implants (13.6%) were placed in the anterior region and 304 implants (86.4%) in the posterior region. The majority of the implants were inserted into bone of type II and III quality (89.8%) and volume (quantity B and C, 87.2%). Most of the implants (70.7%) were restored as single crowns; 28.7% supported a bridge construction and 0.6% a full denture. Only one implant failed, resulting in a four-year cumulative survival rate of 99.7%. Conclusions: The implant system showed an excellent four-year survival rate. It proved to be a safe and predictable means for restoration of the dentition in partially or completely edentulous patients.

단일치 임플란트에서 고정체와 지대주 직경의 차이에 따른 광탄성 응력 분석 (Photoelastic Stress Analysis of Single Implant Restoration According to Implant Fixture Size and Abutment Diameter)

  • 이진한;조혜원
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.253-267
    • /
    • 2008
  • 이 연구의 목적은 임플란트 고정체와 지대주간의 직경 차이가 임플란트 지지조직에 발생하는 응력에 미치는 영향을 평가 하는 것이다. 본 연구에는 세 가지 직경(4.0, 5.0, 6.0㎜)의 3i 임플란트 고정체에 지대주의 직경을 달리하여 수복하고, 하중 조건(15, 30 lb)에 따라 임플란트 지지조직에 발생한 응력의 정도와 분포를 광탄성 응력 분석법을 이용하여 비교, 분석하였다. 연구결과 고정체의 직경이 증가할수록, 상부 보철물에 가해지는 하중에 대하여 고정체 변연부의 응력집중이 높게 나타났으며, 상부 보철물의 근원심 폭경을 증가시키는 것이나, 임플란트 고정체의 직경에 비해 작은 지대주를 사용하는 것은 고정체 주위의 응력양상에 영향을 주지 않았다.

IN VITRO STUDY OF THE TENSILE BOND STRENGTH OF CEMENT-RETAINED SINGLE IMPLANT PROSTHESIS BY THE VARIOUS PROVISIONAL LUTING CEMENTS AND THE SURFACE TREATMENT OF ABUTMENTS

  • Lee, Hwa-Yeon;Lee, Ho-Sang
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.296-305
    • /
    • 2002
  • The main disadvantage of cement-retained implant restorations is their difficulty in retrievability. Advocates of cemented implant restorations frequently state that retrievability of the restoration can be maintained if a provisional cement is used. The purpose of this study was to find the optimal properties of provisional luting cements and the surface treatment of abutments in single implant abutment system. 30 prefabricated implant abutments, height 8mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were obtained. Three commercially available provisional luting agents which were all zinc oxide eugenol type ; Cavitec, TempBond and TempBond NE were evaluated. No cement served as the control. TempBond along with vaseline, a kind of petrolatum (2:1 ratio) was also evaluated. Ten out of thirty abutments were randomly selected and abutment surfaces were sandblasted with $50{\mu}m$ aluminum oxide. Another ten abutments were sandblasted with $250{\mu}m$ aluminum oxide. A vertical groove, 1 mm deep and 5mm long was cut in each twenty abutments. Ten of them were sandblasted with $50{\mu}m$ aluminum oxide. The full coverage casting crowns were cemented to the abutments with the designated provisional luting agent. Specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Each specimen was attached to a universal testing machine. A crosshead speed of 0.5mm/min was used to apply a tensile force to each specimen. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Tensile bond strength of provisional luting cements in no surface treatment decreased with the sequence of TempBond NE, TempBond, Cavitec, TempBond with vaseline, no cement. 2. Tensile bond strength more increased by surface treatment. Sandblasting with $250{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in the abutment cemented with TempBond NE and sandblasting with $50{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in cemented with TempBond. 3. In the aspect of a groove formation, tensile bond strength significantly increased in TempBond with vaseline only and the others had no significant effect on tensile bond strength.

구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구 (A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications)

  • 김정호;이재봉
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.156-163
    • /
    • 2009
  • 연구목적: 4종 구치용도재관(Full-porcelain-occlusal-surfaced PFG, Half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon)과 선별된 한국음식의 fracture load와 dynamic cyclic load를 측정하여 구치용 도재관에 파절을 일으킬 가능성이 있는 한국음식을 선별하는데 있다. 연구재료 및 방법: 4종의 각 porcelain 보철물 system 당 15개의 축대칭을 이루는 crown을 제작했다. 이때 occlusal reduction은 1.5-2.0 mm로 했다(중심부 1.5 mm, 교두부 2.0 mm). 각 15개의 시편의 교합면 중앙부에 직경 5 mm의 stainless steel ball을 위치시킨 후 Instron 4465 universal testing machine(Instron, Norwood, MA USA)을 이용하여 5 mm/min의 crosshead speed로 수직 부하를 주어 파절을 일으키는 최대 부하(N)를 기록했다. 이후, 한국음식 중 삶은 게, 닭(뼈포함), 소갈비(뼈포함), 마른 오징어, 건멸치, 사탕, 호두껍질을 표본으로 설정하고 이들을 파절시키는 최대 부하(N)를 universal testing machine(Instron 4465) 에서 측정하여 기록했다. 각 항목당 15번을 측정했다. 음식물을 파절시킬 때 필요한 최대부하와 각 보철물의 파절저항을 비교하여 한국의 식습관과 도재를 이용한 보철물 파절의 상관관계를 조사하였다. fracture loads는 analysis of variance 와 Post Hoc tests를 이용해서 분석하였다($\alpha$=0.05). 차후에 위에서 얻은 결과를 바탕으로 Hydraulic Dynamic Fatigue Testing Machine(858 Bionix II, MTS systems, Eden Prairie, MN USA)를 이용하여 4종의 각 porcelain 보철물 system당 5개의 crown에 14Hz Cyclic Load를 가하여 crown에 파절을 일으키는 masticatory cycle수를 알아 보았다. Load 수치는 41.0 N(건멸치 파절강도), 169.0 N(마른오징어 파절강도), 382.9 N(닭뼈 파절강도), 2224.8 N(사탕 파절강도)로 설정하였다. 결과: 95% confidence intervals for mean fracture load는 2599.3-2809.1 N(완전도재교합면 PFG), 3689.4-3819.9 N(반도재교합면 PFG), 1501.2-1867.9 N(Ice Zirkon), 803.2-1188.5 N(Empress 2)로 나왔고 95% confidence intervals for dynamic cyclic load on fracture는 instron 상에서 도재보철물에 파절을 일으키지 않은 load인 2224.8 N(사탕 파절강도)와 382.9 N(닭뼈 파절강도)로 실험했을 때, 2224.8 N에서 4796.8-9321.2 cycles(완전도재교합면 PFG), 2224.8 N에서 881705.1-1143565.7 cycles(반도재교합면 PFG), 382.9 N에서 979993.0-1145773.4 cycles(Ice Zirkon), 382.9 N에서 564.1-954.7 cycles(Empress 2)로 나왔다. 결론: 통계학적으로 유의할 만한 차이가 그룹들 간 fracture load에서 나타났다. 한국음식물 중 소갈비(뼈포함)와 사탕(자두맛캔디)은 구치용 도재보철물을 파절시킬 가능성이 있는 음식물로 밝혀졌다. 단일수직부하에서는 파절이 생기지 않는 경우라 할지라도 dynamic cyclic load를 줄 경우 일정 주기 후에 파절이 생기는 결과를 얻을 수 있었다.

전부 피개관의 치아 형성 시 축면 경사각에 대한 조사 (Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns)

  • 김성진;배아란;우이형;김형섭
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.21-32
    • /
    • 2010
  • 삭제된 치아의 경사도는 치관 수복물의 유지와 저항에 있어 매우 중요한 요소이다. 하지만 다양한 구강 내 환경과 술자의 능력에 따라 이상적인 경사도를 얻는 것은 쉽지 않다. 따라서 이상적으로 삭제된 치아의 경사도와 실제 임상에서 삭제된 치아의 경사도를 조사하고자 한다. 본 실험의 연구 자료는 K대학 부속 치과병원 중앙 기공실을 통하여 보철과 전공의가 시술한 환자의 모형과 일반 기공소를 통해 일반 개업의가 시술한 환자의 모형을 수집한다. 연구 방법은 각 치아의 근원심면과 협설면을 디지털 카메라를 통해 촬영한 뒤 'ImageJ' 프로그램 상에서 치아의 삭제 각도를 측정 한 뒤 항목별( 1. 술자 집단별 분류, 2. 치열궁 내에서의 위치에 따른 분류, 3. 삭제 양식에 따른 분류 )로 분류하여 비교 분석한다. 이번 연구를 통해 조사한 결과 국내 임상가의 지대치 형성시 축면 경사각의 평균은 $15.02^{\circ}$ 표준 편차는 ${\pm}10.13^{\circ}$였다. 1. 술자 집단별 분류에 대한 분석 일반 치과의 집단의 측면 경사각과 보철과 전공의 집단의 축면 경사각에서 유의성 있는 차이를 보였다(p<0.05). 2. 치열궁 내에서의 위치에 따른 분석 치아의 근원심면과 협설측면에 따라 일반 치과의 집단의 경우 유의성 있는 차이가 없었으며(p>0.05) 보철과 전공의 집단에서는 유의성 있는 차이를 보였다(p<0.05). 치아의 전후적인 위치에 따라 일반 치과의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며 (p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단의 경우 전치부와 소구치부 사이에 유의성 있는 차이가 없었으며(p>0.05) 두 부위와 대구치부 사이에서는 각각 유의성 있는 차이를 보였다(p<0.05). 상악과 하악으로 분류하여 분석한 경우 일반 치과의 집단에서 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 보철과 전공의 집단에서도 근원심면과 전체적인 축면의 경사각에 각각 유의성 있는 차이가 없었으며(p>0.05) 협설측면에서는 유의성 있는 차이를 보였다(p<0.05). 악궁을 좌측과 우측으로 분류하여 분석한 경우 일반 치과의 집단과 보철과 전공의 집단에서 각각 유의성 있는 차이가 없었다(p>0.05). 3. 삭제 양식에 따른 분석 단일 치관을 위한 지대치와 3본 고정성 부분 의치를 위한 지대치로 분류하여 분석한 결과 일반 치과의 집단에서 근원심면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이를 보였으며(p<0.05) 협설측면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이가 없었다(p>0.05). 보철과 전공의 집단에서는 협설측면의 경우 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의성 있는 차이가 없었으며(p>0.05) 근원심면과 전체적인 축면의 경우 각각 단일 치관을 위한 지대치의 축면 경사각과 3본 고정성 부분 의치를 위한 지대치의 축면 경사각에 유의한 차이를 보였다(p<0.05). 이상에서 임상에서 치아 삭제시 이상적인 축면 경사각을 얻기 힘들며 이는 술자의 경험과 악궁 내에서의 위치, 삭제 양식에 따라 영향을 받을 수 있다.