• Title/Summary/Keyword: Single checking

Search Result 120, Processing Time 0.021 seconds

Household's main activities for decreasing food wastes (가정내 음식물 쓰레기 감량을 위한 소비자 특성별 행위와 요인분석)

  • Han, Jae-Hwan;Hwang, Yun-Jae
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.2
    • /
    • pp.299-306
    • /
    • 2012
  • This study conducted an internet survey to explore consumers' behaviors for reducing food wastes and to examine factors affecting their actions. Consumer survey demonstrates that food preparers at home purchase foods two or three times a week on average and most of food wastes are generated in the process of cooking preparation. Results show that consumers who purchase foods at supermarket reduce food wastes by frequently buying a small amount of foods and checking the expiration date. Consumers with higher income diminish food wastes by purchasing appropriate amount of foods. Interestingly, if husband and wife work together for a living, they are more active for decreasing food wastes compared to a single worker.

The Standard Questionnaire Database System for Rural Development Goal Formulation (마을발전방향 정립을 위한 마을평가용 표준설문지문 데이터베이스 구축)

  • 최수명;황한철;한경수;조영재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.1
    • /
    • pp.87-95
    • /
    • 2001
  • This study aimed at developing the standard questionnaire database system for rural development. By the previous study for the hierarchical listing of the factors related to rural development in the village level, the targetting questionnaire items pool was proposed. The data base system basically consisted of 3 parts: general, principal and sectoral parts for rural development. General and principal parts had the detailed questionnaires without any further hierarchy, but sectoral one 4-step hierarchy from high/medium/low levels to detailed questionnaires. Tentatively, total 417 questionnaires statements were written with 5 questioning styles: single choosing, multiple choosing, tabular, writing and special questions. Through the checking done by college students team from rural area, the database system having 467 questioning statements was finally developed.

  • PDF

Alcohol Gas Sensors using Spray-coated Carbon Nanotube Thin Film (스프레이 코팅된 탄소나노튜브 박막을 이용한 알코올 가스 센서)

  • Kim, Seong-Jeen
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.783-788
    • /
    • 2008
  • We suggest a CNT-based gas sensor for breath alcohol measurement. The sensor was composed of single-walled carbon nanotubes (SWCNTs) thin film on flexible PES (polyethersulfone) substrate, and the SWCNTs thin film was formed by multiple spray-coating with SWCNTs solution which was well-dispersed, highly controlled and functionalized in ethanol solvent. In this work, three types of SWCNTs thin films were deposited with changes in the number of spray-coatings to 20, 40 and 60 times in order to compare electrical response properties of the SWCNTs thin films. from the fabricated sensors, conductance and capacitance responses were measured and discussed. Alcohol gas sensors have been commercialized widely as gauge for breath alcohol measurement which is applicable to checking whether car drivers are drinking-driving or not. Our alcohol gas sensors showed good sensitivity and linearity even at room temperature.

The Accuracy of the Non-continuous I Test for One-Dimensional Arrays with References Created by Induction Variables

  • Zhang, Qing
    • Journal of Information Processing Systems
    • /
    • v.10 no.4
    • /
    • pp.523-542
    • /
    • 2014
  • One-dimensional arrays with subscripts formed by induction variables in real programs appear quite frequently. For most famous data dependence testing methods, checking if integer-valued solutions exist for one-dimensional arrays with references created by induction variable is very difficult. The I test, which is a refined combination of the GCD and Banerjee tests, is an efficient and precise data dependence testing technique to compute if integer-valued solutions exist for one-dimensional arrays with constant bounds and single increments. In this paper, the non-continuous I test, which is an extension of the I test, is proposed to figure out whether there are integer-valued solutions for one-dimensional arrays with constant bounds and non-sing ularincrements or not. Experiments with the benchmarks that have been cited from Livermore and Vector Loop, reveal that there are definitive results for 67 pairs of one-dimensional arrays that were tested.

Selecting optimized mix proportion of bagasse ash blended high performance concrete using analytical hierarchy process (AHP)

  • Praveenkumar, S.;Sankarasubramanian, G.;Sindhu, S.
    • Computers and Concrete
    • /
    • v.23 no.6
    • /
    • pp.459-470
    • /
    • 2019
  • Apart from strength properties, durability, toughness and workability are also important criteria in defining the performance of a concrete structure. Hence "High Performance Concrete (HPC)" is introduced. It is different from high strength concrete and can have various applications. In this paper, the properties (Mechanical and Durability) of High Performance Concrete blended with bagasse ash at 5%, 10%, 15% and 20% are studied. However, it is difficult to analyze the performance based on different properties obtained from different experiments. Hence it is necessary to combine all the criteria/properties into a single value to obtain a result by a technique called Analytical Hierarchy Process (AHP).It is an effective tool for dealing with complex decision making, and may aid the decision maker to set priorities and make the best decision. In addition, the AHP incorporates a useful technique for checking the consistency of the decision maker?s evaluations, thus reducing the bias in the decision making process.

Experimental Comparison of Electrohydraulic Forming of SUS430 with Free Bulging Die Depending on Wire of Electrodes (전극봉의 와이어 체결 유무에 따른 자유 벌징 금형의 액중방전성형 실험을 통한 SUS430 소재의 성형성 비교)

  • Y. H. Jang;M. S. Kim;J. Kim
    • Transactions of Materials Processing
    • /
    • v.32 no.6
    • /
    • pp.303-310
    • /
    • 2023
  • Electrohydraulic forming(EHF), one of the high-speed forming method, can supplement the weak point of previous forming process such as deep-drawing and electromagnetic forming. Indeed, EHF is time-consuming process during installing wire before experiment that hard to apply to industry. In this research, applying wireless electrode, the formability of SUS430 sheet was compared through EHF experiments using wire-installed electrode and the other, wireless. Although the power was a little lacking, the advantages of the experiment using wireless electrode could be confirmed with checking the optimal location of electrodes where the plasma is generated and comparing free-bulging height depending on former and later condition of electrodes with performing several single and multistage experiments for same voltage, 6 kV.

Analysis of corrugated steel web beam bridges using spatial grid modelling

  • Xu, Dong;Ni, Yingsheng;Zhao, Yu
    • Steel and Composite Structures
    • /
    • v.18 no.4
    • /
    • pp.853-871
    • /
    • 2015
  • Up to now, Japan has more than 200 corrugated steel web composite beam bridges which are under construction and have been constructed, and China has more than 30 corrugated steel web composite beam bridges. The bridge type includes the simply supported beam, continuous beam, continuous rigid frame and cable stayed bridge etc. The section form has developed to the single box and multi-cell box girder from the original single box and single chamber. From the stress performance and cost saving, the span range of 50~150 m is the most competitive. At present, the design mostly adopts the computational analytical method combining the spatial bar system model, plane beam grillage model and solid model. However, the spatial bar system model is short of the refinement analysis on the space effect, such as the shear lag effect, effective distribution width problem, and eccentric load factor problem etc. Due to the similarity of the plane beam grillage method in the equivalence principle, it cannot accurately reflect the shearing stress distribution and local stress of the top and bottom plates of the box type composite beam. The solid model is very difficult to combine with the overall calculation. Moreover, the spatial grid model can achieve the refinement analysis, with the integrity of the analysis and the comprehensiveness of the stress checking calculation, and can make up the deficiency of the analytical method currently. Through the example verification of the solid model and spatial grid model, it can be seen that the calculation results for the stress and the displacement of two models are almost consistent, indicating the applicability and precision of the spatial grid model.

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Floating Point Converter Design Supporting Double/Single Precision of IEEE754 (IEEE754 단정도 배정도를 지원하는 부동 소수점 변환기 설계)

  • Park, Sang-Su;Kim, Hyun-Pil;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.72-81
    • /
    • 2011
  • In this paper, we proposed and designed a novel floating point converter which supports single and double precisions of IEEE754 standard. The proposed convertor supports conversions between floating point number single/double precision and signed fixed point number(32bits/64bits) as well as conversions between signed integer(32bits/64bits) and floating point number single/double precision and conversions between floating point number single and double precisions. We defined a new internal format to convert various input types into one type so that overflow checking could be conducted easily according to range of output types. The internal format is similar to the extended format of floating point double precision defined in IEEE754 2008 standard. This standard specifies that minimum exponent bit-width of the extended format of floating point double precision is 15bits, but 11bits are enough to implement the proposed converting unit. Also, we optimized rounding stage of the convertor unit so that we could make it possible to operate rounding and represent correct negative numbers using an incrementer instead an adder. We designed single cycle data path and 5 cycles data path. After describing the HDL model for two data paths of the convertor, we synthesized them with TSMC 180nm technology library using Synopsys design compiler. Cell area of synthesis result occupies 12,886 gates(2 input NAND gate), and maximum operating frequency is 411MHz.

Development of Raw Material Identification Method of Changnan-jeot and Gaiyang-jeot Using Multiplex PCR and Real-Time PCR (Multiplex PCR과 Real-Time PCR을 이용한 창난젓과 가이양젓 원료 검사법 개발)

  • Choi, Seong Seok;Seo, Yong Bae;Kim, Jong-Oh;Yang, Ji-Young;Shin, Jiyoung;Kim, Gun-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.4
    • /
    • pp.289-297
    • /
    • 2021
  • In this study, multiplex PCR and real-time PCR were performed on Theragra chalcogramma (walleye pollock), Pangasianodon hypophthalmus (iridescent shark) and their processed foods, such as changnan-jeot and gaiyang-jeot (salted iridescent shark intestine). Species-specific primers for T. chalcogramma and P. hypophthalmus were designed, and genomic DNA was directly extracted from each sample to perform single PCR and multiplex PCR. As a result of PCR, in the case of single PCR, PCR bands of T. chalcogramma (297 bp) and P. hypophthalmus (132 bp) were identified, and in the case of multiplex PCR, it was confirmed that amplification occurred without cross-reaction between T. chalcogramma and P. hypophthalmus. As a result of checking the PCR sensitivity, the concentration of genomic DNA was detected up to 0.1 ng/µL in both single PCR and multiplex PCR. The real-time PCR results showed that the average Ct value of T. chalcogramma was 20.765±0.691, and the average Ct value of P. hypophthalmus sample was 35.719±1.828 in the T. chalcogramma species-specific primers. In the P. hypophthalmus species-specific primers, the average Ct value of the T. chalcogramma sample was 35.996±1.423, and the mean Ct value of the P. hypophthalmus sample was 20.096±0.793. These results demonstrated the significant differences in the efficiency, specificity and cross-reactivity of species-specific primers in real-time PCR. Based on these findings, 7 of changnan-jeot or gaiyang-jeot products were confirmed by multiplex PCR and real-time PCR, and valid results were confirmed in all samples.