• Title/Summary/Keyword: Single and Double

Search Result 2,710, Processing Time 0.033 seconds

Probabilistic Evaluation on Prediction Accuracy of the Strains by Double Surface and Single Surface Constitutive Model (확률론에 의환 Double Surface와 Single Surface 구성모델의 변형을 예측 정도의 평가)

  • Jeong, Jin Seob;Song, Young Sun;Kim, Chan Kee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.217-229
    • /
    • 1994
  • A probabilistic method was employed to compare the prediction accuracy of axial and volumetric strains of Lade's double surface model with that of single surface model. Several experiments were conducted to examine the variabilities of soil parameters for two models using Back-ma river sand. Mean values and standard deviations of soil parameters obtained from experimental data were used for the evaluation of the uncertainty of analyzed strains by the first order approximation. It is shown that the variabilities of parameters in the single surface model are more consistent than those of the double surface model. However, in the accuracy of axial strain by probabilistic analysis, double surface model is more stable than single surface model. It is also shown that two models are excellent in view of the accuracy of the volumetric strain. The method given in this paper may be effectively utilized to estimate the constitutive model because other results of the comparison of two models coincide with those of this paper.

  • PDF

Friction Effects on the Performance of Double-Bumped Air Foil Bearings (이중범프포일 공기베어링의 성능에 미치는 마찰효과)

  • Kim, Young-Cheol;Lee, Dong-Hyun;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.23 no.4
    • /
    • pp.162-169
    • /
    • 2007
  • This paper deals with friction effects on the performance of double-bumped AFBs. The stiffness and damping coefficients of the double bump vary depending on the external load and its friction coefficient. The double bump can be either in the single or double active region depending on vertical deflection. The equivalent stiffness and damping coefficients of the bump system are derived from the vertical and horizontal deflection of the bump, including the friction effect. A static and dynamic performance analysis is carried out by using the finite difference method and the perturbation technique. The results of the performance analysis for a double-bumped AFB are compared with those obtained for a single-bumped AFB. This paper successfully proves that a double bumped AFB has higher load capacity, stiffness, and damping than a single-bumped AFB in a heavily loaded condition.

Double Sampling with Zero Acceptance Number for the First Sample

  • Bai, Do-Sun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.3 no.2
    • /
    • pp.99-106
    • /
    • 1977
  • A double sampling procedure with zero acceptance number for the first sample whose operating characteristic closely matches that of a given single sampling plan and whose combined sample size does not exceed that of the given single sampling plan is proposed. The proposed double sampling plans corresponding to the MIL-STD-105D plans are tabulated and it is found that their ASN's are considerably smaller than those of corresponding MIL-STD-105D single or double sampling plans.

  • PDF

Improvement of Electrochemical Performance of Lithium-ion Secondary Batteries using Double-Layered Thick Cathode Electrodes

  • Phiri, Isheunesu;Kim, Jeong-Tae;Kennedy, Ssendagire;Ravi, Muchakayala;Lee, Yong Min;Ryou, Myung-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.1
    • /
    • pp.32-41
    • /
    • 2022
  • Various steps in the electrode production process, such as slurry mixing, slurry coating, drying, and calendaring, directly affect the quality and, consequently, mechanical properties and electrochemical performance of electrodes. Herein, a new method of slurry coating is developed: Double-coated electrode. Contrary to single-coated electrode, the cathode is prepared by double coating, wherein each coat is of half the total loading mass of the single-coated electrode. Each coat is dried and calendared. It is found that the double-coated electrode possesses more uniform pore distribution and higher electrode density and allows lesser extent of particle segregation than the single-coated electrode. Consequently, the double-coated electrode exhibits higher adhesion strength (74.7 N m-1) than the single-coated electrode (57.8 N m-1). Moreover, the double-coated electrode exhibits lower electric resistance (0.152 Ω cm-2) than the single-coated electrode (0.177 Ω cm-2). Compared to the single-coated electrode, the double-coated electrode displays higher electrochemical performance by exhibiting better rate capability, especially at higher C rates, and higher long-term cycling performance. Despite its simplicity, the proposed method allows effective electrode preparation by facilitating high electrochemical performance and is applicable for the large-scale production of high-energy-density electrodes.

Comparison of Single and Double Fusions in Transverse Tarsal Joint (횡족근 관절의 단일 및 이중 유합술의 비교)

  • Youn, Hyun-Kook;Lee, Jong-Seok;Lee, Jin-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the clinical and radiological results of single and double fusions in the transverse tarsal joint. Materials and Methods: Between December 2000 and April 2009, 16 patients (16 feet) who had been treated by fusion of transverse tarsal joint were included in this study. In 8 patients, only talonavicular joint was fused and in the other 8 patients, both talonavicular and calcaneocuboid joints were fused simultaneously. We have measured talo-first metatarsal angle, calcaneal pitch angle, talonavicular coverage angle and presence of adjacent joint arthritis for radiological assessment at both preoperative and last visit. Furthermore, we have evaluated Visual Analogue Scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score and patient's satisfaction. Results: In a single fusion group, VAS was improved from $6.4{\pm}1.4$ to $0.8{\pm}1.0$ (p=0.0011) and AOFAS score was improved from $63.8{\pm}6.2$ to $89.4{\pm}9.8$ (p=0.0012). In a double fusion group, VAS was improved from $8.0{\pm}0.75$ to $2.0{\pm}1.8$ (p=0.0011) and AOFAS score was improved from $60.5{\pm}11.2$ to $89.5{\pm}6.0$ (p=0.0012). In the difference of talo-first metatarsal angle between two groups, a single fused group was more improved than a double fused group (p=0.04). Conclusion: Both single and double fusions are useful and attractive treatment for the transverse tarsal joint arthritis. Furthermore, a single fusion has advantages of less invasiveness and preserving some degree of hindfoot motion and could be an effective alternative to a double fusion if patient meets appropriate criteria through careful preoperative evaluation.

The Experimental Study on the Effects of Dansamyeum on Hyperlipidemia (단삼음(丹蔘飮)이 고지혈증(高脂血症)에 미치는 영향(影響))

  • Kim, Byeung-Chul;Park, Chi-Sang;Park, Chang-Gook;Lee, Eun-Ju
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.126-134
    • /
    • 2000
  • Objectives : In order to study effects of Dansamyeum on Hyperlipidemia which causes Hypertension, Arteriosclerosis, Cerebral vascular disease and Ischemic heart disease Methods : The changes of serum total lipid, triglyceride, total cholesterol, HDL-cholesterol, LDL-cholesterol, body weight and organ weight were observed after the liquid extracts of Single-dosage Dansamyeum and Double-dosage Dansamyeum were administered p.o to the Hyperlipidemic rats induced by 1% cholesterol diet for 10, 20 and 30 days. Results : The body weight was significantly decreased in Double-dosage Dansamyeum group for 20 and 30 days compared with control group. The contents of total lipid were significantly decreased in Single-dosage Dansamyeum group for 20 days, but Double-dosage Dansamyeum group did not show any significant change compared with control group. The contents of total cholesterol were significantly decreased in Single-dosage Dansamyeum group for 20 days, and Double-dosage Dansamyeum group showed significant changes for 10 and 20 days compared with control group. The contents of triglyceride were significantly decreased in Single-dosage Dansamyeum group for 30 days, and Double-dosage Dansamyeum group showed significant changes for 10 days compared with control group. The contents of HDL-cholesterol were significantly increased in Single-dosage Dansamyeum group and Double-dosage Dansamyeum group for 10 days compared with control group. The contents of LDL-cholesterol were significantly decreased in Single-dosage Dansamyeum group for 10, 20 and 30 days, and Double-dosage Dansamyeum group showed significant changes for 10, 20 and 30 days compared with control group. The liver weight was significantly decreased in Single-dosage Dansamyeum group and Double-dosage Dansamyeum group compared with control group. The kidney and testis weight was significantly decreased in Single-dosage Dansamyeum group compared with control group. The spleen weight was significantly decreased in Double-dosage Dansamyeum group compared with control group. Conclusions : It was thought that Single-dosage Dansamyeum and Double-dosage Dansamyeum could be applied effectively to the Hyperlipidemia.

  • PDF

A Comparison of the Characteristics between Single and Double Finger Gestures for Web Browsers

  • Park, Jae-Kyu;Lim, Young-Jae;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.629-636
    • /
    • 2012
  • Objective: The purpose of this study is to compare the characteristics of single and double finger gestures related on the web browser and to extract the appropriate finger gestures. Background: As electronic equipment emphasizes miniaturization for improving portability various interfaces are being developed as input devices. Electronic devices are made smaller, the gesture recognition technology using the touch-based interface is favored for easy editing. In addition, user focus primarily on the simplicity of intuitive interfaces which propels further research of gesture based interfaces. In particular, the fingers in these intuitive interfaces are simple and fast which are users friendly. Recently, the single and double finger gestures are becoming more popular so more applications for these gestures are being developed. However, systems and software that employ such finger gesture lack consistency in addition to having unclear standard and guideline development. Method: In order to learn the application of these gestures, we performed the sketch map method which happens to be a method for memory elicitation. In addition, we used the MIMA(Meaning in Mediated Action) method to evaluate gesture interface. Results: This study created appropriate gestures for intuitive judgment. We conducted a usability test which consisted of single and double finger gestures. The results showed that double finger gestures had less performance time faster than single finger gestures. Single finger gestures are a wide satisfaction difference between similar type and difference type. That is, single finger gestures can judge intuitively in a similar type but it is difficult to associate functions in difference type. Conclusion: This study was found that double finger gesture was effective to associate functions for web navigations. Especially, this double finger gesture could be effective on associating complex forms such as curve shaped gestures. Application: This study aimed to facilitate the design products which utilized finger and hand gestures.

POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN USING DOUBLE CURING UNIT SYSTEM (Double curing unit system을 이용한 복합 레진의 광중합 수축에 관한 연구)

  • Han, Mi-Ran;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • As a part of an effort to minimize the polymerization shrinkage which is considered to be a major cause of failed bonds to tooth, newly designed 'Double LED system' was tested in the present study. Analyses were performed on the pattern of micro-leakage and the changes of strain which have occurred during the polymerization process. The results can be summarized as follows: 1. In the strain change, dramatic increase was observed with initiation of polymerization which was followed by subsequent gradual decrease with elapse of time in both the single LED system and double LED system. 2. The single LED system were shown to develop and maintain the maximum stress more than double LED system(p<0.05). 3. Less micro-leakage was found in the double LED system than in the single LED system(p<0.05). From the above-mentioned results, the double LED system can be a very useful tool in a sense of reducing polymerization shrinkage when compared to the single LED system. However, practical problems such as size of curing unit and its application method with its light intensity should be solved before its clinical application.

  • PDF

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

A Experimental Study on the Effect of Kami-Daesihotang on Hyperlipidemia & Hypertension (대시호탕가미방(大柴胡湯加味方)이 고혈압(高血壓) 및 고지혈증(高脂血症)에 미치는 영향(影響))

  • Park, Chi-Sang;Park, Chang-Gook;Han, Seung-Dong;Park, Soon-Dal
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.159-184
    • /
    • 1998
  • The aim of the study was the experiment of the effect that Kami-Daesihotang had on the essential hypertension and hyperlipidemia. Rats were orally administered with Kami-Daesihotang for 30days and the constituent of the plasma and serum were analysed at the 10th, 20th and 30th day from the first day of experiment, respectively. The heart rate, blood pressure, plasma renin activity, plasma level of aldosterone, catecholamine, sodium and angiotensin II were measured after an oral administration of Kami-Daesihotang in SHR. In addition, serum levels of total cholesterol, triglyceride, HDL-cholesterol, LDL-cholesterol and total lipid were measured with cholesterol-fed rats. The results were summarized as following ; 1. Single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang remarkably decreased the blood pressure in SHR. 2. Double-dosage Kami-Daesihotang were recognized as having the effect on the decreased of the pulse rate in SHR. 3. Plasma renin activity was significantly decreasd in SHR after single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang treatment. 4. Double-dosage Kami-Daesihotang considerably reduced the plasma angiotensin level in SHR. 5. Noticeable decreased of plasma norepinephrine level was showed in SHR, after single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang treatment. 6. Single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang noticeable reduced body weight in hyperlipidemia rats which had fed with 1% cholesterol. 7. Single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang had a significantly decreasing effect on serum total cholesterol in hyperlipidemia rats which had fed with 1% cholesterol. 8. Serum triglyceride level was importantly decreased in hyperlipidemia rats which had fed with 1% cholesterol, after single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang treatment. 9. Remarkable decreased of serum low density lipoprotein cholesterol level was found in hyperlipidemia rats which had fed with 1% cholesterol, after single-dosage Kami-Daesihotang & double-dosage Kami-Daesihotang treatment. 10. Double-dosage Kami-Daesihotang was showed a significantly decreasing effect on serum total lipid level in hyperlipidemia rats which had fed with 1% cholesterol. 11. Single-dosage Kami-Daesihotang noticeably reduced organ weight of liver, kidney, spleen and testis in hyperlipidemia rats which had fed with 1% cholesterol. Double-dosage Kami-Daesihotang significantly decreased organ weight of liver, kidney and spleen in hyperlipidemia rats. These Findings suggest a possible anti-hypertensive and hyperlipidemic effect of Kami-Daesihotang.

  • PDF