• 제목/요약/키워드: Single and Double

검색결과 2,729건 처리시간 0.03초

불임 환자의 치료에서 Mild Ovarian Hyperstimulation을 이용한 Single IUI와 Double IUI의 비교 (A Comparison Study of Single with Double Intrauterine Insemination with Mild Ovarian Hyperstimulation for Infertility Patients)

  • 손영수;이상훈
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제31권3호
    • /
    • pp.191-200
    • /
    • 2004
  • Objective: To compare the clinical efficacy of double intrauterine insemination with single intrauterine insemination in GnRH antagonist combined ovarian hyperstimulation (Mild ovarian hyperstimulation) Materials and Methods: From Jan. 2001 to Jul. 2004, a retrospective clinical analysis was done of a total of 295 cycles in 170 patients who underwent ovarian hyperstimulation for ART (assisted reproductive technique). Subjects were divided into three groups; only clomiphene citrate ovarian hyperstimulation (n=55, 95cycles), GnRH antagonist combined ovarian hyperstimulation (soft ovarian hyperstimulation) (n=66 99cycles), and GnRH agonist combined ovarian hyperstimulation (short protocol) (n=49, 101cycles) Each group were randomly devided into two subgroups. One group underwent single IUI and the other group underwent double IUI. Results: GnRH antagonist group and GnRH agonist group had similar pregnancy rate. In GnRH antagonist Group, pregnancy rate was 36.1% in single IUI subgroup and was 36.6% in double IUI subgroup. These finding were not statistically significant. And Pregnancy rate was 20.8% in single IUI subgroup and was 19.3% in double IUI subgroup in single clomiphene citrate group, and 36.3% in single IUI subgroup and was 33.3% in double IUI subgroup in GnRH agonist group. These finding were not statistically significant, too. Conclusion: Pregnancy rate of GnRH antagonist was high and complication rate such as OHSS and multiple pregnancy was lower. In GnRH antagonist group, to compare with single IUI and double IUI, the result do not statistically differ. So GnRH antagonist single injection with single IUI was relatively comparable ART in infertiliry patient.

단정도/배정도 승산을 위한 $200-MHz{\circled}a2.5-V$ 이중 모드 승산기 (A $200-MHz{\circled}a2.5-V$ Dual-Mode Multiplier for Single/Double-Precision Multiplications)

  • 이종남;박종화;신경욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.149-152
    • /
    • 2000
  • A dual-mode multiplier (DMM) that performs single- and double-precision multiplications has been designed. An algorithm for efficiently implementing double-precision multiplication with a single-precision multiplier was proposed, which is based on partitioning double-precision multiplication into four single-precision sub-multiplications and computing them with sequential accumulations. When compared with conventional double-precision multipliers, our approach reduces the hardware complexity by about one third resulting in small silicon area and low-power dissipation at the expense of increased latency and throughput cycles.

  • PDF

2중 원형동관의 2축압축 변형특성에 관한 연구 (Biaxial Compressive Deformation Characteristics of Double Round Copper Pipes)

  • 유종근;원시태
    • 소성∙가공
    • /
    • 제23권1호
    • /
    • pp.35-40
    • /
    • 2014
  • The deformation characteristics of a double round copper pipe and a single round copper pipe under biaxial compression were studied using a horizontal compression die. The change in punch load and in deformation behavior was measured during the experiments using various compressive deformation rates in the range of 10mm/min. ~ 450mm/min. The maximum punch load for both the double round copper pipe and the single round copper pipe decreased with increasing compressive deformation rate. The maximum punch load for the single round copper pipe was twice that of the double round copper pipe. After a 4.0mm stroke, the deformed shape of the single round copper pipe remained rectangular. However the outer tube of double round copper pipe remained rectangular while the inner tube was clover shaped. The stress and strain distributions in the double round copper pipe and the single round copper pipe show clear differences. The results of numerical simulations using Deform-2D are in good agreement with experimental results.

이중범프포일 공기베어링의 성능해석 (Performance Analysis of Double-Bumped Air Foil Bearings)

  • 김영철;이동현;김경웅
    • Tribology and Lubricants
    • /
    • 제23권3호
    • /
    • pp.123-129
    • /
    • 2007
  • This paper presents a theoretical model for the analysis of double-bumped AFBs. The stiffness and damping coefficients of the double bump vary depending on the external load and its friction coefficient. In the case of a lightly loaded condition where only the upper bump contributes to deformation, the double bump is in the single active region. In the case of a heavily loaded condition where both the upper and lower bumps contribute to deformation, the double bump is in the double active region. So the double bump can be either in the single or double active region depending on vertical deflection. The equivalent stiffness and damping coefficients of the bump system are derived from the vertical and horizontal deflection of the bump, including the friction effect. A static and dynamic performance analysis is carried out by using the finite difference method and the perturbation technique. The results of the performance analysis for a double-bumped AFB are compared with those obtained for a single-bumped AFB. This paper successfully proves that a double bumped AFB has higher load capacity, stiffness, and damping than a single-bumped AFB in a heavily loaded condition.

In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals

  • Yilmaz, Koray;Uslu, Gulsah;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.282-289
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. Materials and Methods: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). Results: In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). Conclusions: Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.

양발로 선 자세와 한발로 선 자세의 자세안정도 검사 (Postural stability test of double leg support and single limb stance)

  • 권미지
    • 대한물리치료과학회지
    • /
    • 제5권4호
    • /
    • pp.851-860
    • /
    • 1998
  • The purpose of this study was to quantitatively observe changes in postural stability of double leg support and single limb stance. Thirty-six healthy subjects participated in the study. Postural stability were examined using Dynamic Balance System. Each trial was 25 sec in duration. Each of 6 conditions{double leg support and single limb stance ; eyes open in stable platform, eyes closed in stable platform, eyes open in dynamic platform) evaluated effect of visual, vestibular, proprioceptive system. Center of balance found for displacement to the left along the X axis in double leg support and to the forward on left toe in single limb stance. Sway index was the lowest in double leg support with eyes open in stable platform and the higher in single limb stance with eyes closed in stance platform. We believe that reliable and valid measures should be used to determine the contributing factors of our client's postural problems so that we can design the most effective treatment possible.

  • PDF

가로수 조성 유형에 따른 비용편익 비교 분석 (Cost-Benefit Analysis for Planting Type of Street Trees)

  • 김준순;이동근
    • 한국환경복원기술학회지
    • /
    • 제17권6호
    • /
    • pp.29-37
    • /
    • 2014
  • The objective of this study is to estimate the cost and benefits of street trees for their planting types, specifically, single row, single row+bottom, double row, double row+bottom. Different planting types are compared and analyzed by using Net Present Value (NPV) and benefit-cost ratio (BCR). Existing data are collected from the literature reviews for the use of meta-analysis method for estimating cost and benefit. The elements for analyzing costs are management and planting costs, and benefits are air purification, energy saving and landscape view. The discount rate is applied at a minimum of 3% and a maximum of 5.5%. The unit used in this calculation is km/year. The result shows that the net benefit is highest in double row, followed by single row, double row+bottom, and single row+bottom. The BCR is the highest in double row, followed by single row, double row+bottom, and single row+bottom. The BCR reaches the break-even point from 9 to 17 years depending on the planting types.

복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구 (A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

월견초(月見草)가 고지혈증(高脂血症)에 미치는 영향(影響) (A Experimental Study on the Effect of Evening primrose on Hyperlipidemia)

  • 이은주;박치상;박창국
    • 대한한방내과학회지
    • /
    • 제19권2호
    • /
    • pp.139-158
    • /
    • 1998
  • In order to study the anti-hyperlipidemic effects of Evening primrose, the changes of body weight, serum total cholesterol, serum HDL-cholesterol, serum triglyceride, serum LDL-cholesterol, serum total lipid and organ weight were observed after the liquid extracts of Single-dosage Evening primrose and Double-dosage Evening primrose were administered p.o to the hypercholestemic and hypertriglyceremic rats induced by 1% cholesterol diet during 10, 20, 30 days. The result were summarized as follows ; 1. The contents of body weight compared with control group was significantly decreased in single-dosage Evening primrose group during 10, 30 days and in double-dosage Evening primrose group did not show significant value. 2. The contents of serum total cholesterol with control group tend to be decreased in single-dosage Evening primrose group, but did not show significant value. Double-dosage Evening primrose group showed significant value during 20, 30 days. 3. The contents of serum HDL-cholesterol compared with control group was significantly increased in single-dosage Evening primrose group during 10, 20, 30 days. Double-dosage Evening primrose group showed significantly value during 30 days. 4. The contents of serum triglyceride compared with control group was significantly decreased in single-dosage Evening primrose group during 10, 30 days. Double-dosage Evening primrose group showed significant value during 20 days. 5. The contents of serum LDL-cholesterol compared with control group was significantly decreased in single-dosage Evening primrose group during 10 days. Double-dosage Evening primrose group showed significant value during 10, 20, 30 days. 6. The contents of serum total lipid compared with control group was significantly decreased in single-dosage Evening primrose group during 20 days. Double-dosage Evening primrose group showed significant value during 20, 30 days. 7. The contents of liver weight compared with control group was significantly decreased in single-dosage Evening primrose group and double-dosage Evening primrose group. The contents of kidney weight compared with control group was significantly decreased in single-dosage Evening primrose group. The contents of spleen weight compared with control group was significantly decreased in single-dosage Evening primrose group and double-dosage Evening primrose group. The contents of testis weight compared with control group tend to decreased in single-dosage Evening primrose group and double-dosage Evening primrose group, put did not show a significant value. From the above results, it was thought that Evening primrose could be applied effectively to the Hyperlipidemia.

  • PDF

단면형 로터리경운날의 경운 특성 (Tillage Characteristics of the Single-Edged Rotary Blade)

  • 이승규;김성태;우종구
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.369-378
    • /
    • 2000
  • The purpose of this study is to developed high-efficient rotary tillage system for a power tiller by improving the rotary blade. A kind of the rotary blade with single-edged blade(DS) was developed that requires lower tillage energy than conventional double-edged blade(CD) on the design theory for Japanese rotary blade. In order to find out the tillage characteristics between the single-edged blade and the double-edged blade for power tiller, experiments were performed in soil-bins which were filled up clay loam, loam and sandy loam, and then analyzed the effects of the factors such as soil texture, travelling speed, rotational speed, and tillage depth to each of the blades. And field tests were carried out to compare tillage performances of the two blades using rotary cultivator driven by conventional power tiller. The results of this study were summarized as follows; 1) On the soil bin experiment, it was found that tillage torque of the single-edged blade was less than the ones of the double-edged blade. The decreasing ratios of maximum tillage torque of the single-edged blade to the ones of the double-edged blade were 1 to 8% at clay loam, 5 to 20% at loam and 9 to 31% at sandy loam, respectively. 2) By the field tests, that the tillage performances with the single-edged blade compared with the double-edged blade was improved about 19% in field capacity, about 34% in fuel consumption, and 12.5% in soil breaking ratio. Furthermore, the fluctuation of engine speed, the variation of exhaust gas temperature, and the amount of soil clogging on the blade and straw wound on the rotary shaft showed lower values with the developed blade than the conventional blade. So, it may be concluded that tillage performance by the developed single-edged blade was improved compared with the one by the conventional double-edged blade.

  • PDF