• 제목/요약/키워드: Single Plate System

검색결과 226건 처리시간 0.023초

다중 다공판 시스템의 흡음계수 계산에 있어서 전기음향등가회로법의 오류 (The Error Involved in the Equivalent Electroacoustic Circuit Approach for the Estimation of the Absorption Coefficient of Multiple Layer Perforated Plate Systems)

  • Lee, Dong-Hoon;Kim, Wook;Kwon, Young-Pil
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.387.2-387
    • /
    • 2002
  • The equivalent electroacoustic circuit approach has been conventionally used for estimating the absorption coefficient of a single layer perforated plate system. When the single layer system is extended to the multiple layer ones, however, it is found that an analogy error has been involved in the equivalent electroacoustic parallel circuit approach proposed by previous researchers. The analogy error is demonstrated by the corrected equivalent electroacoustir circuit approach proposed en this study.

  • PDF

기하학적 비선형성을 갖는 평판의 동특성 해석 (Dynamic Analysis of a Geometrical Non-linear Plate)

  • 임재훈;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.498-503
    • /
    • 2003
  • Dynamic analysis of a plate with non-linearity due to large deformation is performed in the study. There have been many researches about the non-linear dynamic behavior of plates examining by means of theoretical or numerical analyses. But it is important how exactly model the actual system. In this respect, the Continuous-Time system identification technique is used to generate non-linear models, for stiffness and damping terms, to explain the observed behaviors with single mode assumptions for the simplicity after comparing the experimental results with the numerical results of a linear plate model.

  • PDF

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가 (CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE)

  • 손정희;박지화;김진수;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.

단일 Camera를 이용한 Ball and Plate 로봇 제어장치 설계 (Design of Ball and Plate Robot controller using Single Camera)

  • 박이근;박주연;박성모
    • 한국멀티미디어학회논문지
    • /
    • 제16권2호
    • /
    • pp.213-225
    • /
    • 2013
  • 본 논문에서는 단일 카메라와 2개의 모터를 이용하는 볼-플레이트 로봇제어장치를 설계하는 방법과 제어 오차를 줄이는 방법을 제안한다. 볼-플레이트 시스템을 설계하기 위해서는 볼의 상태 파악과 플레이트의 균형 유지가 필요하다. 볼의 상태는 캠시프트 알고리즘을 이용하여 추적하고 칼만필터로 공의 위치 오차를 보정한다. 플레이트 균형은 두 개의 모터를 움직여 제어하는데 측정 오차가 적은 DC모터를 사용하였다. 플레이트의 표면적 상태나 공의 위치 추적오류 등을 인하여 작은 오차가 여전히 남아있다. 이러한 오차는 점점 쌓이게 되며 결국은 볼의 균형유지를 방해하게 된다. 이를 해결하기 위해 적분기를 추가한 제어기를 제안한다.

제철소 후판공장 전원공급설비의 용량 최적화에 관한 연구 (A Study on the Optimization of Power Supply Equipment for Plate Mill Plant in Steelworks)

  • 고현옥;박지호;김동완
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1300-1305
    • /
    • 2014
  • In this paper, we suggest an optimization method which can save about 5[%] of the cost though the optimizing of configuration and capacity for the facility. To achieve this goal, we compared the design data of the power, motor and drive system with the actual operation data of the plate mill plant in K-Steelworks. Therefore we measured the actual loading data by facilities considering the operating conditions of the plate mill plant in K-Steelworks, after that analyzed these data. In addition, we review the optimal capacity for transformer, switchgear and drive, and also reconfigured the electrical room and power single line diagram through the validation of motor data by equipment and the confirmation of process data considering the load characteristics. Consequently, the optimization method of capacity for the facilities shall have effectiveness in building new plate mill plant to further reduce costs at future.

단상유동 조건에서 용접형 판형 열교환기의 열전달 및 압력강하 특성연구 (Heat Transfer and Pressure Drop Characteristics of Brazed Plate Heat Exchangers with Single-Phase Flow)

  • 김만배;박창용
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.522-528
    • /
    • 2014
  • This experimental study measured and analyzed the heat transfer and pressure drop performance of brazed plate heat exchangers. Heat exchangers with different plate numbers of 10, 20, 30, and 40 were used for measurement, and their plate pattern was identical. The experiment was performed with distilled water, by changing the hot-side flow rate, with the cold-side flow rate fixed. The experimental results were compared with the calculated values by correlations based on gasketed plate heat exchangers, and showed that the heat transfer performance and pressure drop of brazed plated heat exchangers were higher than those of gasketed plate heat exchangers. From the variation of the friction factor, it could be inferred that in the flow channels of brazed plate heat exchangers, turbulent flow occurred at Reynolds numbers higher than 500. A new correlation to predict the Nusselt number was developed, and its absolute average deviation was 2.62%, compared with the values from the experimental data.

스퍼 기어계의 방사소음 예측 (Prediction of Radiated Noise from a Spur Gear System)

  • 박찬일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.334-339
    • /
    • 2000
  • In order to predict the noise of the spur gear system, a simplified model of spur system including the housing is studied. The spur gear is modeled as a single degree of freedom system. The shaft-housing system is modeled as a clamped circular plate connected with a beam. The moment components of the beam excited by the spur gear mesh force are considered in the calculation of plate vibration and radiated noise. The out-of-displacements of the clamped circular plate due to the r-direction moment and ${\theta}$-direction moment are calculated. Radiated noise from the plate in the air is also calculated using Rayleigh integral. Using the numerical example, the numerical validation of the analytical procedure on the noise prediction are given.

  • PDF

능동 진동제어를 위한 시스템 동정 (System Identification for Active Vibration control)

  • 송철기;황진권;최종호;이장무
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.397-401
    • /
    • 1994
  • This paper proposes an identification method for a thin plate where multiple actuators and sensors are bonded. Since a thin plate has small damping ratios of all modes, each mode can be identified seperately with a bandpass filter for each modal signal. With the bandpass filter and the characteristics of the plate, the Multi-Input Multi-Output (MIMO) model of the plate can be converted to several Multi-Input Single-Output(MISO) models of second order linear difference equations of the modes. Parameters for each mode are obtained by using the Least Square method. Form there MISO models, the MIMO model is obtained in the form of the state space. Experiments were performed for an all-clamped plate with two pairs of piezoelectric actuators and sensors. The outputs of the identified model and the experimental data match well.

  • PDF

중주파수 해석을 위한 웨이브 모형 연구: 두개의 보와 판 연성계 (A wave model of two identical beams coupled by a plate for a mid-frequency analysis)

  • ;;유지우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.771-775
    • /
    • 2006
  • There has been much effort to find suitable methods for structural analysis in the mid-frequency region where traditional low frequency methods have increasing uncertainties whilst statistical energy analysis is not strictly applicable. Systems consisting of relatively stiff beams coupled to flexible plates have a particularly broad mid-frequency region where the beams support only a few modes whilst the plate has a high modal density and modal overlap. A system of two parallel beams coupled to a plate is investigated based on the wave method, which is an approximate method. The wave model is extended from a single-beam-plate system, to a plate with two identical beams which is modelled using a symmetric-anti symmetric technique. Experimental results such as powers and energy ratios show the validity of the analytical wave models.

  • PDF