• Title/Summary/Keyword: Single Phase Operation

Search Result 488, Processing Time 0.034 seconds

The 1.6[kW] Class Single Phase ZCS-PWM High Power Factor Boost Rectifier (1.6[kW]급 단상 ZCS-PWM HPF 승압형 정류기)

  • Mun, S.P.;Kim, S.I.;Yun, Y.T.;Kim, Y.M.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1169-1171
    • /
    • 2003
  • This paper presents a 1.6[kW]class single phase high power factor(HPF) pulse width modulation(PWM) boost rectifier featuring soft commutation of the active switches at zero current. It incorporates the most desirable properties of conventional PWM and soft switching resonant techniques. The input current shaping is achieved with average current mode control and continuous inductor current mode. This new PWM converter provides zero current turn on and turn off of the active switches, and it is suitable for high power applications employing insulated gate bipolar transistors(IGBT'S). The principle of operation, the theoretical analysis, a design example, and experimental results from laboratory prototype rated at 1.6[kW] with 400[Vdc] output voltage are presented. The measured efficiency and the power factor were 96.2[%] and 0.99[%], respectively, with an input current Total Harmonic Distortion(THD) equal to 3.94[%], for an input voltage with THD equal to 3.8[%], at rated load.

  • PDF

Single-Phase Utility-Interactive Inverter for Residential Fuel Cell Generation System (가정용 연료전지 발전 시스템을 위한 단상 계통연계형 인버터)

  • Jung, Sang-Min;Bae, Young-Sang;Yu, Tae-Sik;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • In this paper, a new single-phase utility-interactive inverter system for residential power generation with fuel cell is proposed. The proposed inverter system is not only capable of working in both stand-alone and grid-connected mode, but also ensures smooth and automatic transfer between the two modes of operation. The proposed control method has little steady-state error and good transient response characteristic. Also, the control method can be implemented using low-cost, fixed point DSP since it has simpler structure, smaller amount of calculation, and smaller number of sensors. The controller for the proposed utility-interactive inverter system is described, and the validity is verified through simulation and experiment.

A Study on sine-wave Input Current Correction of Single-Phase Buck Rectifier (단상 강압형 정류기의 정현파 입력전류 개선에 관한 연구)

  • Jung, S.H.;Lee, H.W.;Suh, K.Y.;Kwon, S.K.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.180-182
    • /
    • 2001
  • Input Current Correction of Single-Phase Buck Rectifier is studied in the paper. To sinusoidal waveform the input current with a near-unity power factor over a wide variety of operating conditions, the output capacitor is operated with voltage reversibility for the supply by arranging the auxiliary diode and power switching device. Then the output voltage is superposed on the input voltage during on time duration of power switching devices in order to minimize the input current distortion caused by the small input voltage when changing the polarity. The tested setup, using two insulated-gate bipolar transistors(IGBT) and a microcomputer, is implemented and IGBT are switched with 20[kHz], which is out of the audible band. Moreover, a rigorous state-space analysis is introduced to predict the operation of the rectifier. The simulated results confirm that the input current can be sinusoidal waveform with a near-unity power factor and a satisfactory output voltage regulation can be achieved.

  • PDF

Effect of Pulse Width Modulation Methods on Power Losses and Thermal Loadings of Single-Phase 5-Level NPC Inverters for PV Systems (전압 변조 방법에 따른 단상 5-레벨 NPC 태양광 인버터의 전력 손실 및 열 부하 분석)

  • Ryu, Taerim;Choi, Ui-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2022
  • In this paper, the effect of pulse width modulation methods on thermal loadings and power losses of single-phase five-level NPC inverters for photovoltaic systems are analyzed. The pulse width modulation methods affect the power losses of the NPC inverters and thus lead to different thermal loadings of NPC inverters. To identify the reliability-critical power device with respect to thermal stress, the thermal loadings of I- and T-type NPC inverters are analyzed by applying the unipolar pulse modulation method. Then, the effect of the discontinuous pulse width modulation method on power losses and thermal loadings of power devices of I- and T-type NPC inverters are analyzed. Finally, the operation of NPC inverters applying the discontinuous pulse modulation method is confirmed by experiments. The results show that the discontinuous pulse modulation method is able to improve the reliability of NPC inverters by reducing thermal loadings of reliability-critical power devices and it is more effective for T-type NPC inverters than I-type NPC inverters.

Tunable Er$^{3+}$ dopsd Fier DFB Laser (파장 가변 어븀 첨가 광섬유 DFB 레이저)

  • Yoon, Hong;Cho, Kyu-Man;Lee, Sang-Bae;Kim, Sang-Hyuk;Choi, Sang-Sam
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.429-433
    • /
    • 2000
  • A study of the tunable fiber DFB laser using PZT-stretcher is presented. The device has an laser ocsillator by using a fiber Bragg grating at 1559.4 nm written directly into a 3-cm long $Er^{3+}$ doped fiber. Post UV-exposure method to provide the necessary phase shift is used for a single mode operation. The device shows the single mode operation of $230\muW$ output power and has a narrow linewidth of 35 kHz. The lasing wavelength of the laser can be tuned in a range of 3 nm by stretching the grating.rating.

  • PDF

A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor (3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구)

  • Choi, Shin-Hyeong;Kwak, Dong-Kurl;Kim, Jin-Hwan
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • In the three-phase power system using the three-phase motor, when any one-phase is open-phase, the unbalanced current flows and the single-phase power supplied by power supply produces overcurrent to motor coil. As a result, the enormous damage and electrical fire can be given to the power system. Recently, the thermal over-current relay (THR) or electronic motor protection relay (EMPR) is mostly used as the open-phase detection device of the three-phase motor. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for openphase protection using semiconductor devices. Therefore, the proposed open-phase protection device (OPPD) enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight. As a result, the proposed OPPD protects the three-phase motor, minimizes the electrical fire from openphase, and contributes for the stable driving of the power system. The performance and confidence of the proposed OPPD is confirmed by a great variety of the experiments of operation characteristic.

Catalytic Characteristics of Perovskite-type Oxides under Mixed Methane and Oxygen Gases (메탄-산소 혼합가스 조건에서의 페롭스카이트계 산화물의 촉매특성 평가)

  • Ahn, Ki-Yong;Kim, Hyoung-Chul;Chung, Yong-Chae;Son, Ji-Won;Lee, Hae-Won;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.4
    • /
    • pp.232-237
    • /
    • 2008
  • As the single chamber SOFC(SC-SOFC) showed higher prospect on reducing the operation temperature as well as offering higher design flexibility of SOFCs, lots of concerns have been given to investigate the catalytic activity of perovskite-type oxide in mixed fuel and oxidant conditions. Hence we thoroughly investigated the catalytic property of various perovskite-type oxides such as $La_{0.8}Sr_{0.2}MnO_3(LSM),\;La_{0.6}Sr_{0.4}CoO_3(LSC),\;La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3(LSCF),\;Sm_{0.5}Sr_{0.5}CoO_3(SSC),\;and\;Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}(BSCF)$ under the partial oxidation condition of methane which used to be given for SC-SOFC operation. In this study, powder form of each perovskite oxides whose surface areas were controlled to be equal, were investigated as functions of methane to oxygen ratios and reactor temperature. XRD, BET and SEM were employed to characterize the crystalline phase, surface area and microstructure of prepared powders before and after the catalytic oxidation. According to the gas phase analysis with flow-through type reactor and gas chromatography system, LSC, SSC, and LSCF showed higher catalytic activity at fairly lower temperature around $400^{\circ}C{\sim}450^{\circ}C$ whereas LSM and BSCF could be activated at much higher temperature above $600^{\circ}C$.

Design of Antenna for Beam Scanning for Dual-Band base station (이중대역 기지국용 빔 스캔 안테나 설계)

  • Ko Jin-Hyun;Jang Jae-Su;Ha Jae-Kwon;Park Sae-Houn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.632-636
    • /
    • 2006
  • It is needed to use the beam scanning to control the cell coverage of the base station considering operation conditions, season, time period, radiation character and mobility of customers and vehicles for varied wireless communication service and quality improvement. This paper proposes a mobile antenna system which can obtain the characteristics of the beam scanning by controlling the directivity depending on the operation condition. Radiation block is made of 2 sub-array of $1\times3$ patched antennas for ITS of 5.8GHZ bandwidth with the gain of 13dBi, and of 2 sub-array of single patched antenna for WiBro of 2.3GHZ bandwidth with the gain of 12dBi. RF module is made of a switch, an amplifier, a PAD, a 3-Bit phase shifter, and a power divider. The system is able to control the beam tilting with electronic methode by using 3-bit phase shifter$(45^{\circ},\;90^{\circ},\;180^{\circ})$.

  • PDF

A Design of Prescaler with High-Speed and Low-Power D-Flip Flops (고속 저전력 D-플립플롭을 이용한 프리스케일러 설계)

  • Park Kyung-Soon;Seo Hae-Jun;Yoon Sang-Il;Cho Tae-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.8 s.338
    • /
    • pp.43-52
    • /
    • 2005
  • An prescaler which uses PLL(Phase Locked Loop) must satisfy high speed operation and low power consumption. Thus the performance or TSPC(True Single Phase Clocked) D-flip flops which is applied at Prescaler is very important. Power consumption of conventional TSPC D-flip flops was increased with glitches from output and unnecessary discharge at internal node in precharge phase. We proposed a new D-flip flop which reduced two clock transistors for precharge and discharge Phase. With inserting a new PMOS transistor to the input stage, we could prevent from unnecessary discharge in precharge phase. Moreover, to remove the glitch problems at output, we inserted an PMOS transistor in output stage. The proposed flip flop showed stable operations as well as low power consumption. The maximum frequency of prescaler by applying the proposed D-flip flop was 2.92GHz and achieved power consumption of 10.61mw at 3.3V. In comparison with prescaler applying the conventional TSPC D-flip $flop^[6]$, we obtained the performance improvement of $45.4\%$ in the view of PDP(Power-Belay-Product).

Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line (경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석)

  • Choi, Chang Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.