A Study on the Separation of Fetal ECG from a Single Channel Abdominal ECG (단일채널 복부 심전도를 통한 태아 심전도 분리)

  • Park Kwang-Li;Lee Kyoung-Joung;Lee Jeon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • In this paper, we proposed a new algorithm for the separation of fetal ECG from single channel abdominal ECG. The algorithm consists of a stage of demixing vector calculation for initial signal and a stage of fetal beat detection for the rest of signal. The demixing vector was obtained by applying independent component analysis technique to projected signals into time-frequency domain. For the test of this algorithm, simulation signals, De Lathauwer's data and some measured data, which was acquired from 8 healthy volunteers whose pregnant periods ranged from 22 weeks to 35 weeks and whose ages from 27 to 37, were used. For each data, the accuracy of fetal beat detection was $100\%$ and with the location of fetal beats, fetal heart rate variability and morphology could be offered. In conclusion, this proposed algorithm showed the possibility of fetal beat separation with a single channel abdominal ECG and it might be adopted to a fetal health monitoring system, by which a single channel abdominal ECG is acquired.

A New Method for the Fetal ECG Extraction from a Signle Channel Maternal ECG (단일채널 산모 복부 심전도로부터 새로운 태아 심전도 검출 방법)

  • Song, M.H.;Cho, S.P.;Kim, Y.W.;Choi, H.S.;Lee, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.467-468
    • /
    • 2007
  • In this paper, we have proposed a new method to extract the fetal ECG from a pregnant woman's abdominal signal using least square acceleration (LSA) filter and adaptive impulse correlation (AIC) filter. To evaluate the performance, the proposed method and other fetal ECG extraction techniques were processed using the real ECG data and then the results were compared. According to comparative results, the proposed method is powerful and successful for extracting the fetal ECG. It was able to separate perfectly even though the fetal beats overlap with the QRS wave of the maternal beats and to extract fetal ECG using any single-channel abdominal signal measured from pregnant woman's abdominal surface. Also, it could be implemented easily by fast computation time and simple structure. It is sure that our method could be useful for portable fetal monitoring system.

  • PDF