• Title/Summary/Keyword: Single Chamber

Search Result 458, Processing Time 0.023 seconds

The combustion characteristics of vehicle upholsteries

  • Park, Hyung-Ju;Kang, Young-Goo;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.211-218
    • /
    • 1997
  • Five parts of vehicle upholsteries were sampled to determine its combustion characteristics. Oxygen Indexer, Smoke chamber, Differential Scanning Calorimetry(DSC) are applied as the analysis apparatus. All LOI values of samples appear less than 21. The combustion phenomena of vehicle upholster primarily depends on properties of each layer material. The amount of smoke generated is the experiment reached the maximum value within 30-90sec after ignition. The experimental results of combustion characteristics and DSC of H/Line also indicated that the layer of foam was melt first and it caused the propagation of flame through the sample. The combustion characteristics of multi layer materials primarily depend on thermal characteristic of single layer material.

  • PDF

Numerical investigation of detonation combustion wave propagation in pulse detonation combustor with nozzle

  • Debnath, Pinku;Pandey, K.M.
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.3
    • /
    • pp.187-202
    • /
    • 2020
  • The exhaust nozzle serves back pressure of Pulse detonation combustor, so combustion chamber gets sufficient pressure for propulsion. In this context recent researches are focused on influence of nozzle effect on single cycle detonation wave propagation and propulsion performance of PDE. The effects of various nozzles like convergent-divergent nozzle, convergent nozzle, divergent nozzle and without nozzle at exit section of detonation tubes were computationally investigated to seek the desired propulsion performance. Further the effect of divergent nozzle length and half angle on detonation wave structure was analyzed. The simulations have been done using Ansys 14 Fluent platform. The LES turbulence model was used to simulate the combustion wave reacting flows in combustor with standard wall function. From these numerical simulations among four acquaint nozzles the highest thrust augmentation could be attained in divergent nozzle geometry and detonation wave propagation velocity eventually reaches to 1830 m/s, which is near about C-J velocity. Smaller the divergent nozzle half angle has a significant effect on faster detonation wave propagation.

Multi type heat pump system computer simulation and experimental verification (멀티형 히트펌프 시스템 컴퓨터 시뮬레이션과 실험적 검증)

  • 한도영;정민영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.12-19
    • /
    • 2000
  • The multi type heat pump system may provide more energy savings and better environmental conditions than the single type heat pump system may do. In order to design a multi type heat pump system, it may be recommended to develop the system simulation program, which can predict the characteristics of the system such as unit capacities, power consumptions, and system COP's. In this study, the steady state simulation program of the multi type heat pump system was developed. The results from the simulation program were compared with those from the experimental tests which were performed in the environmental chamber, Cooling tests show 3.11% and 0.94% of error in capacity and COP, and heating tests show 3.30% and 1.90% of error in capacity and COP, respectively. Therefore, the steady state simulation program developed for this study can effectively be used for the design and the performance prediction of the multi type heat pump system.

  • PDF

Development of a Mushroom Powder Certified Reference Material for Element Analysis

  • Betru, Tegegn Gizachew;Yim, Yong-Hyeon;Lee, Kyoung-Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.108-112
    • /
    • 2020
  • A certified reference material (CRM) for the analysis of nutrient elements in an edible mushroom (Ganoderma lyceum) powder has been developed (KRISS CRM 108-10-011). The mass fractions of calcium (Ca), iron (Fe), and zinc (Zn) were measured by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). To dissolve the fungi cell wall of mushroom consisted of chitin fibers, sample preparation method by single reaction chamber type microwave-assisted acid digestion with acid mixtures was optimized. The mean measurement results obtained from 12 sample bottles were used to assign as the certified values for the CRM and the between-bottle homogeneities were evaluated from the relative standard deviations. The certified values were metrologically traceable to the definition of the kilogram in the International System of Units (SI). This CRM is expected to be used for validation of analytical methods or quality control of measurement results in analytical laboratories when they determine the mass fractions of elements in mushroom or other similar samples.

Resolution of Malignant Hypertension after Single-Chamber Permanent Pacemaker Implantation in a Dog with 3rd Degree AV Block

  • Su-Min Park;Woo-Jin Song;Hwa-Young Youn
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.50-55
    • /
    • 2023
  • A 10-year-old spayed female Cocker spaniel weighing 6.64 kg was presented with a sign of syncope. Electrocardiographic findings revealed pathologic atrioventricular (AV) block alternating 3rd degree AV block, non-responsive to atropine. Before pacemaker implantation, several anti-hypertensive medications were administered, but there was no improvement. After pacemaker implantation, the heart rate and systemic arterial systolic blood pressure were immediately improved. This is the first report on the resolution of an AV block and malignant systemic hypertension after a pacemaker implant in veterinary medicine.

Design and Implementation of a Multi-purpose Test Equipment with a Large Utilization Range for use in Electric Fire (전기화재 분야에서 다목적으로 시험장치의 활용범위를 증가시키기 위한 시험장치의 설계 및 구현)

  • Dongcheol Shin;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.180-186
    • /
    • 2023
  • Test devices can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the launch of combined products. However, the scope of use of test devices is limited because they perform only a single role or could only serve a particular purpose in the past. Therefore, studies on test devices that can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the release of combined products are necessary. Accordingly, this study proposes a test device that can increase the scope of use in the technical field of electric fires. In addition, we examine various outcomes of the proposed test device.

MEMS-based Direct Methanol Fuel Cells and Their Stacks for the Reduction of Cell-to-Cell Deviation and Interconnection Voltage Drop (단위 셀간 성능편차 및 접속접안 강하 초소화를 위한 극소형 직접메탄올 연료전지 스택의 설계 및 제작)

  • Seo, Young-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.981-985
    • /
    • 2007
  • We present a MEMS-based portable Direct Methanol Fuel Cell (micro-DFMC), featured by a platinum sputtered microcolumn electrode and a built-in fuel chamber containing a limited amount of methanol fuel. Also presented is a micro-DMFC stack structure having a common electrolyte sandwiched by the microcolumn electrodes. The single cells with ME16 and PE16 electrodes show the maximum power densities of $31.04{\pm}0.29{\mu}W/cm^2$ and $9.75{\pm}0.29{\mu}W/cm^2$, respectively; thus indicating the microcolumn electrode (ME16) generates the power density (3.2 times) higher than the planar electrode (PE16). The single cell tests of ME16 and ME4 electrodes (Fig.8) show the maximum power of $31.04{\pm}0.29{\mu}W/cm^2$, and $25.23{\pm}2.7{\mu}W/cm^2$, respectively; thus demonstrating the increased window frame reduces the normalized standard power deviation (standard deviation over the average power). The normalized deviation of 0.11 in ME4 cell has been reduced to 0.01 in ME16 cell due to the increased window frames. The maximum power density of 4-cell stack is 15.7 times higher than that of the single cell. 4-cell stack produces the power capacity of 20.3mWh/g during 980min operation at the voltage of 450mV with the load resistance of $800{\Omega}$.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

Analysis of corrugated steel web beam bridges using spatial grid modelling

  • Xu, Dong;Ni, Yingsheng;Zhao, Yu
    • Steel and Composite Structures
    • /
    • v.18 no.4
    • /
    • pp.853-871
    • /
    • 2015
  • Up to now, Japan has more than 200 corrugated steel web composite beam bridges which are under construction and have been constructed, and China has more than 30 corrugated steel web composite beam bridges. The bridge type includes the simply supported beam, continuous beam, continuous rigid frame and cable stayed bridge etc. The section form has developed to the single box and multi-cell box girder from the original single box and single chamber. From the stress performance and cost saving, the span range of 50~150 m is the most competitive. At present, the design mostly adopts the computational analytical method combining the spatial bar system model, plane beam grillage model and solid model. However, the spatial bar system model is short of the refinement analysis on the space effect, such as the shear lag effect, effective distribution width problem, and eccentric load factor problem etc. Due to the similarity of the plane beam grillage method in the equivalence principle, it cannot accurately reflect the shearing stress distribution and local stress of the top and bottom plates of the box type composite beam. The solid model is very difficult to combine with the overall calculation. Moreover, the spatial grid model can achieve the refinement analysis, with the integrity of the analysis and the comprehensiveness of the stress checking calculation, and can make up the deficiency of the analytical method currently. Through the example verification of the solid model and spatial grid model, it can be seen that the calculation results for the stress and the displacement of two models are almost consistent, indicating the applicability and precision of the spatial grid model.

A SCATTERING MECHANISM IN OYSTER FARM BY POLARIMETRIC AND JERS-l DATA

  • Lee Seung-Kuk;Won Joong Sun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.538-541
    • /
    • 2005
  • Tidal flats develop along the south coast ofthe Korean peninsula. These areas are famous for sea farming. Specially, strong and coherent radar backscattering signals are observed over oyster sea farms that consist of artificial structures. Tide height in oyster farm is possible to measure by using interferometric phase and intensity of SAR data. It is assumed that the radar signals from oyster farm could be considered as double-bouncing returns by vertical and horizontal bars. But, detailed backscattering mechanism and polarimetric characteristics in oyster farm had not been well studied. We could not demonstrate whether the assumption is correct or not and exactly understand what the properties of back scattering were in oyster farm without full polarimetric data. The results of AIRSAR L-band POLSAR data, experiments in laboratory and JERS-l images are discussed. We carried out an experiment simulating a target structure using vector network analyser (Y.N.A.) in an anechoic chamber at Niigata University. Radar returns from vertical poles are stronger than those from horizontal poles by 10.5 dB. Single bounce components were as strong as double bounce components and more sensitive to antenna look direction. Double bounce components show quasi-linear relation with height of vertical poles. As black absorber replaced AI-plate in bottom surface, double bounce in vertical pole decreased. It is observed that not all oyster farms are characterized by double bounced scattering in AIRSAR data. The image intensity of the double bounce dominant oyster farm was investigated with respect to that of oyster farm dominated by single bounce in JERS-l SAR data. The image intensity model results in a correlation coefficient (R2 ) of 0.78 in double bounce dominant area while that of 0.54 in single bouncing dominant area. This shows that double bounce dominant area should be selected for water height measurement using In8AR technique.

  • PDF