• Title/Summary/Keyword: Simultaneously Measurements

Search Result 383, Processing Time 0.036 seconds

PSD sensor array design for the 3D measurement of moving objects (이동 물체의 3차원 계측을 위한 PSD 센서 배열 설계)

  • Kim, Jon-Man;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.106-113
    • /
    • 2008
  • Perceiving a 3D moving target is important for automated machines including robots in a factory. Although stereovision or ultrasonic ranging is often employed for the purpose, the former requires high-cost systems, and the latter suffers from low-resolution. In this paper, we propose a PSD sensor array to acquire the 3D profile of an object conveyed by a belt. Rectangular parallelepiped target objects at random positions and orientations are assumed. Nine PSD sensors are configured in a $3{\times}3$ array above the belt, and fired in a sequence so that cross-talk can be avoided. Time gaps among sensor readings are compensated to get a result that is obtainable when sensors' measurements are made simultaneously along a sensing line. The system designed is tested with various objects in experiments.

Identification of 18 flutter derivatives by covariance driven stochastic subspace method

  • Mishra, Shambhu Sharan;Kumar, Krishen;Krishna, Prem
    • Wind and Structures
    • /
    • v.9 no.2
    • /
    • pp.159-178
    • /
    • 2006
  • For the slender and flexible cable supported bridges, identification of all the flutter derivatives for the vertical, lateral and torsional motions is essential for its stability investigation. In all, eighteen flutter derivatives may have to be considered, the identification of which using a three degree-of-freedom elastic suspension system has been a challenging task. In this paper, a system identification technique, known as covariance-driven stochastic subspace identification (COV-SSI) technique, has been utilized to extract the flutter derivatives for a typical bridge deck. This method identifies the stochastic state-space model from the covariances of the output-only (stochastic) data. All the eighteen flutter derivatives have been simultaneously extracted from the output response data obtained from wind tunnel test on a 3-DOF elastically suspended bridge deck section-model. Simplicity in model suspension and measurements of only output responses are additional motivating factors for adopting COV-SSI technique. The identified discrete values of flutter derivatives have been approximated by rational functions.

Quantitative Measurements of Soot Particles in a Laminar Diffusion Flame Using a LII/LIS Technique (LII/LIS 기법을 이용한 층류확산화염 매연입자의 정량화)

  • Chung, J.W.;Lee, W.;Han, Y.T.;Kim, B.S.;Lee, C.B.;Kim, D.J.;Lee, K.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2003
  • In this study, the quantification of soot particles in laminar diffusion flame with LII/LIS methods was performed. In these quantification, soot diameter, number density and volume fraction are included. For the quatification of soot particles, calibration tests are needed and the development of algorithm has to be performed. So, in this study, extinction and scattering test at co-flow burner were performed to acquire calibration data. And algorithm for LII/LIS simultaneous measurement for the quantification of soot were developed. The algorithm, which was the quantification of simultaneous photographing using one ICCD camera, to measure LII/LIS signal simultaneously, the best fitted light intensity and acquisition time was needed.

  • PDF

Fault Diagnosis of System Using Fault Pattern (고장 패턴을 이용한 시스템의 고장진단)

  • Lee, Jin-Ha;La, Kyung-Taek;Lee, Young-Seog;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.988-990
    • /
    • 1999
  • Using neural network approach, the diagnosis of faults in industrial process that requires observing multiple data simultaneously are studied in this paper. Two-stage diagnosis is proposed as the basic structure. The first stage detects the dynamic trend of each measurements and the second stage diagnosis the faults. This paper makes up for the disadvantage of neural about unknown faults. The potential of this approach is demonstrated in simulation using a model of tank reactor.

  • PDF

A STUDY ON THE SIMULTANEOUS MEASUREMENTS OF BETA EMITTING ISOTOPES

  • Lee, Goung-Jin;Kim, Seoung-Pyung
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.155-159
    • /
    • 2001
  • Beta radiation is measured for an environmental monitoring purpose or for an internal radiation exposure monitoring of nuclear power plant's worker. In korea, strontium 89 and strontium 90 is measured for an environmental monitoring purpose. Also tritium and carbon 14 contained in urine is measured for an internal radiation exposure monitoring of nuclear power plant's worker. Because above isotopes emits low energy beta radiations having a wide range of energy, very complicated isotope separation preprocess is needed. In this study, two mixed beta emitting isotopes are measured simultaneously using a liquid scintillation counter(LSC) and analyzed by using a developed statistical method. Banded least square method is used to analyze the mixed spectrum, and the goodness-of-fitness test is proposed. Test results show that the developed procedure can be very useful for analyzing a mixed beta emitting isotopes.

  • PDF

Paper-Based Bipolar Electrochemistry

  • Renault, Christophe;Scida, Karen;Knust, Kyle N.;Fosdick, Stephen E.;Crooks, Richard M.
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.146-152
    • /
    • 2013
  • We demonstrate that carbon electrodes screen-printed directly on cellulose paper can be employed to perform bipolar electrochemistry. In addition, an array of 18 screen-printed bipolar electrodes (BPEs) can be simultaneously controlled using a single pair of driving electrodes. The electrochemical state of the BPEs is read-out using electrogenerated chemiluminescence. These results are important because they demonstrate the feasibility of coupling bipolar electrochemistry to microfluidic paperbased analytical devices (${\mu}PADs$) to perform highly multiplexed, low-cost measurements.

Application of Transfer Insensitive Labeling Technique (TILT) in Ischemic Cerebrovascular Diseases

  • 이승구;김동익;김상흠;김시연;인연권
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.169-169
    • /
    • 2001
  • Purpose: To assess the clinical usefulness of Transfer Insensitive Labeling Technique (TILT) in t evaluation of ischemic cerebrovascular disease. Method: Arterial spin labeling (ASL) is a method of perfusion weighted imaging usin endogenous water as a tracer. To avoid MT-related artifacts, which is common in usual A technique, a transfer insensitive labeling technique (TILT) was used, which globall manipulate macromolecular spins in the same way by both labeling and reference preparatio while free water is labeled in one case and left unchanged in the other. Philips Interal 1.5 T system was used. 40cm FOV and 32 repeated measurements were done because of the wea perfusion signal. 5 slices of supratentorial brain were obtained in 5 patients {MCA infar (n=3), moyamoya disease (n=2)}. We simultaneously obtained contrast enhanced T2*-weighted perfusion MRI and correlate to TILT images.

  • PDF

A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser (2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계)

  • 김민석;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF

Construction of a prototype free-ranging AGV system

  • Lee, Sang-Ryong;Bae, Joon-Young;Kwon, Seung-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1343-1348
    • /
    • 1990
  • The architecture and functions of a prototype free ranging AGV system are described in this paper. The system has single tricycle configuration - the front wheel is driven and steered simultaneously. The primary position measurement device of this system is the redundant encoder system - an absolute encoder for the steering angle measurement of the front wheel, two incremental encoders for the measurement of the rear wheel rotations. The secondary position measurement device is implemented to reduce the accumulatad error in encoder measurements. The extended Kalman filter is suggested to combine the conflict measurement data for the proper position estimation.

  • PDF

The Strain of Flexible Ring Type Valve used for Refrigeration Compressor (냉동압축기용(冷凍壓縮機用) 환상형토출(環狀型吐出)밸브의 변형(變形))

  • Jeong, J.W.;Jo, K.O.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.2
    • /
    • pp.150-158
    • /
    • 1988
  • On a refrigeration compressor, damage of a discharge valve is one of the annoying troubles for an engineer. Small size compressors, having ring plate type discharge valve are recently used. Therefore, it is very important for engineers to measure and analyze strains of discharge valve. The purpose of this study is to obtain the basic data of the strain of the flexible ring valve. Measurements were performed by the strain gauge bonded on the surface of the flexible ring valve. Stress and strain of the valve were calculated by the method of uniformly loaded circular plates with a central hole. The results obtained are as follows; (1) the strain of flexible ring discharge valve in refrigeration compressor was influenced by tension and compression strain simultaneously. (2) for a given discharge pressure, the tangential and radial strains was increased with increasing discharge pressure. (3) the valve of radial strain was larger than that of tangential strain.

  • PDF