• Title/Summary/Keyword: Simultaneous measurements

Search Result 264, Processing Time 0.023 seconds

A study on the sequential algorithm for simultaneous estimation of TDOA and FDOA (TDOA/FDOA 동시 추정을 위한 순차적 알고리즘에 관한 연구)

  • 김창성;김중규
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.7
    • /
    • pp.72-85
    • /
    • 1998
  • In this paper, we propose a new method that sequentially estimates TDOA(Time Delay Of Arrival) and FDOA(Frequency Delay Of Arrival) for extracting the information about the bearing and relative velocity of a target in passive radar or sonar arrays. The objective is to efficiently estimate the TDOA and FDOA between two sensor signal measurements, corrupted by correlated Gaussian noise sources in an unknown way. The proposed method utilizes the one dimensional slice function of the third order cumulants between the two sensor measurements, by which the effect of correlated Gaussian measurement noises can be significantly suppressed for the estimation of TDOA. Because the proposed sequential algoritjhm uses the one dimensional complex ambiguity function based on the TDOA estimate from the first step, the amount of computations needed for accurate estimationof FDOA can be dramatically reduced, especially for the cases where high frequency resolution is required. It is demonstrated that the proposed algorithm outperforms existing TDOA/FDOA estimation algorithms based on the ML(maximum likelihood) criterionandthe complex ambiguity function of the third order cumulant as well, in the MSE(mean squared error) sense and computational burden. Various numerical resutls on the detection probability, MSE and the floatingpoint computational burden are presented via Monte-Carlo simulations for different types of noises, different lengths of data, and different signal-to-noise ratios.

  • PDF

Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I) (다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I))

  • Ahn, Jae-Hyun;Kim, Yong-Mo;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Substructural parameters and dynamic loading identification with limited observations

  • Xu, Bin;He, Jia
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.169-189
    • /
    • 2015
  • Convergence difficulty and available complete measurement information have been considered as two primary challenges for the identification of large-scale engineering structures. In this paper, a time domain substructural identification approach by combining a weighted adaptive iteration (WAI) algorithm and an extended Kalman filter method with a weighted global iteration (EFK-WGI) algorithm was proposed for simultaneous identification of physical parameters of concerned substructures and unknown external excitations applied on it with limited response measurements. In the proposed approach, according to the location of the unknown dynamic loadings and the partially available structural response measurements, part of structural parameters of the concerned substructure and the unknown loadings were first identified with the WAI approach. The remaining physical parameters of the concerned substructure were then determined by EFK-WGI basing on the previously identified loadings and substructural parameters. The efficiency and accuracy of the proposed approach was demonstrated via a 20-story shear building structure and 23 degrees of freedom (DOFs) planar truss model with unknown external excitation and limited observations. Results show that the proposed approach is capable of satisfactorily identifying both the substructural parameters and unknown loading within limited iterations when both the excitation and dynamic response are partially unknown.

A New Iron Emission Template for Active Galactic Nuclei

  • Park, Daeseong;Barth, Aaron J.;Ho, Luis C.;Laor, Ari
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.36.2-36.2
    • /
    • 2019
  • Fe II emission is a prominent and ubiquitous feature in the spectra of broad-line Active Galactic Nuclei (AGN) by producing a pseudo-continuum from UV to optical with complex and strong blends of the numerous emission lines themselves, other emission lines, and continuum. Since theoretical modeling of such intricate Fe II emission is very difficult and still far from able to reproduce observed data in detail, an empirical iron emission template, derived from observations of a narrow-line Seyfert 1 galaxy, is an essential and practical tool to obtain accurate measurements of all the emission lines and continuum in AGN spectra. However, the existing iron templates, based on the single prototypical strong Fe II emitter I Zw 1, are suffering from inadequate S/N and non-simultaneous, inconsistent data with limited wavelength coverage, which consequently limit the accuracy of all the spectral measurements. To overcome the limitations and construct an improved iron template with wide spectral coverage, high-quality UV and optical spectra for the new and better identified template galaxy, Mrk 493, were successfully obtained from our HST STIS program (GO-14744). We will show the preliminary results for multicomponent spectral decomposition of the data and template construction with application tests to various AGN spectra and comparison with previous templates.

  • PDF

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Development of a Laser Absorption NO/$NO_2$ Measuring System for Gas Turbine Exhaust Jets

  • Zhu, Y.;Yamada, H.;Hayashi, S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.802-806
    • /
    • 2004
  • For the protection of the local air quality and the global atmosphere, the emissions of trace species including nitric oxides (NO and NO$_2$) from gas turbines are regulated by local governments and by the International Civil Aviation Organization. In-situ measurements of such species are needed not only for the development of advanced low-emission combustion concepts but also for providing emissions data required for the sound assessment of the effects of the emissions on environment. We have been developing a laser absorption system that has a capability of simultaneous determination of NO and NO$_2$concentrations in the exhaust jets from aero gas turbines. A diode laser operating near 1.8 micrometer is used for the detection of NO while a separated visible tunable diode laser operating near 676 nanometers is used for NO$_2$. The sensitivities at elevated temperature conditions were determined for simulated gas mixtures heated up to 500K in a heated cell of a straight 0.5 m optical path. Sensitivity limits estimated as were 30 ppmv-m and 3.7 ppmv-m for NO and NO$_2$, respectively, at a typical exhaust gas temperature of 800K. Experiments using the simulated exhaust flows have proven that $CO_2$ and $H_2O$ vapor - both major combustion products - do not show any interference in the NO or NO$_2$ measurements. The measurement system has been applied to the NO/NO$_2$ measurements in NO and NO$_2$ doped real combustion gas jets issuing from a rectangular nozzle having 0.4 m optical path. The lower detection limits of the system were considerably decreased by using a multipass optical cell. A pair of off-axis parabola mirrors successfully suppressed the beam steering in the combustion gas jets by centralizing the fluctuating beam in sensor area of the detectors.

  • PDF

Strain Rates and OH Layer Characteristics in Stabilization Region for Turbulent Non-premixed Jet Flames Close to Blowoff (동축공기 난류제트확산화염의 화염날림 근처에서의 변형률 및 OH 특성)

  • Hwang, Jeongjae;Kim, Taesung;Yoon, Jisu;Yoon, Youngbin
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.211-213
    • /
    • 2014
  • Simultaneous measurements of planar laser-induced fluorescence (PLIF) of OH radicals and particle image velocimetry (PIV) were used to investigate the strain rates and OH structure characteristics of turbulent syngas non-premixed jet flames close to blowoff. Mean values of the maximum principal strain rate on OH layer decreases with the axial distance, and its standard deviation is significantly large upstream. Strain rate on stabilization region of the stable flame is only about a half of that of the flame near blowoff.

  • PDF

Comparison of Simultaneous Measurements of $PM_{10}$ in Ambient Air (환경대기 중 미세먼지($PM_{10}$)의 동시측정 비교 연구)

  • 조석주;최금숙;여인학;이민환;김민영;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.267-268
    • /
    • 2003
  • 환경매계(environmental matrices)에 존재하는 오염물질의 농도측정과 관련된 측정의 객관성을 확보하기 위하여 가장 중요한 기준은 측정농도의 신뢰도를 확보하는 것을 들 수 있으며, 특히 토양이나 물과 달리 비정형화 된 매개인 대기 중에 존재하는 오염물질을 채취ㆍ분석하고 비교할 때, 분석화학적인 관점에서 객관성을 확보하고 유지하기 위해서는, 연구를 주관하는 모든 연구주체들이 기존 측정방식에 대한 철저한 검증을 시도하고, 이를 바탕으로 새로운 분석방식의 개발을 추진하는 것이 중요하다. (김기현 et al., 1999) (중략)

  • PDF

A Study on the Estimation of One-dimensional Beat Fluxes on the Slab in Reheating Furnace by Using Inverse Analysis (역해석을 이용한 가열로 내 소재의 1차원 열유속 추정에 관한 연구)

  • Kang, Deok-Hong;Kwag, Dong-Seong;Kim, Woo-Seung;Lee, Yong-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • This study deals with the use of the conjugate gradient method for the simultaneous estimation of two unknown boundary heat fluxes on the slab in reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. The heat flux estimations for three different cases of measurement locations in the slab are performed: non-skid, skid, and shift-skid zones. The estimated heat fluxes for three cases indicated the three regions having local peak values of heat fluxes. The estimated temperatures at measurement locations were in good agreements with the measured temperatures within 5% relative error.

A Study on Natural Convection Flows Using Particle Image Analysis (입자영상해석에 의한 자연대류 유동에 관한 연구)

  • Bae, D.S.;Kim, N.S.;Cho, W.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.2
    • /
    • pp.11-16
    • /
    • 2000
  • Simultaneous quantitative measurements are made of the velocity fields for two-dimensional natural convection in a rectangular enclosure using PIV(Particle Image Velocimetry). The experiments are performed at a Prandtl number of 6.62, an aspect ratio of 1.0, Rayleigh numbers from $1.294{\times}10^6\;to\;3.8841{\times}10^6$, and angles of inclination of $0^{\circ},\;30^{\circ}\;and\;60^{\circ}$ inside a $30mm{\times}30mm{\times}8mm$ cavity made of an acrylic glass 10mm, with two isothermal copper walls kept at a prescribed temperature. The experimental results agreed very well with the numerical results. It was found that the flow consisted of a large double convection cell at angle of inclination of $60^{\circ}$.

  • PDF