• 제목/요약/키워드: Simultaneous instrumentation

검색결과 20건 처리시간 0.026초

Actuator Fault Diagnostic Algorithm based on Hopfield Network

  • Park, Tae-Geon;Ryu, Ji-Su;Hur, Hak-Bom;Ahn, In-Mo;Lee, Kee-Sang
    • 한국지능시스템학회논문지
    • /
    • 제10권3호
    • /
    • pp.211-217
    • /
    • 2000
  • A main contribution of this paper is the development of a Hopfield network-based algorithm for the fault diagnosis of the actuators in linear system with uncertainties. An unknown input decoupling approach is introduced to the design of an adaptive observer so that the observer is insensitive to uncertainties. As a result, the output observation error equation does not depend on the effect of uncertainties. Simultaneous energy minimization by the Hopfield network is used to minimize the least mean square of errors of errors of estimates of output variables. The Hopfield network provides an estimate of the gains of the actuators. When the system dynamics changes, identified gains go through a transient period and this period is used to detect faults. The proposed scheme is demonstrated through its application to a simulated second-order system.

  • PDF

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

단일 영상과 거리센서를 이용한 SLAM시스템 구현 (Implementation of the SLAM System Using a Single Vision and Distance Sensors)

  • 유성구;정길도
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.149-156
    • /
    • 2008
  • SLAM(Simultaneous Localization and Mapping)은 무인 로봇 자동 항법시스템의 중요 기술로 센서 데이터로부터 로봇의 위치를 결정하고 기하학적 맵을 구성하는 것이다. 기존 방법으로는 초음파, 레이저 등의 거리 측정 센서를 이용해 로봇의 전역 위치를 찾는 방법과 스테레오 비전을 통한 방법이 개발되었다. 거리 측정 센서만으로 구성한 SLAM 시스템은 계산량이 간소하고 비용이 적게 들지만 센서의 오차나 비선형에 의해 정밀도가 조금 떨어진다. 이에 반해 스테레오 비전 시스템은 3차원 공간영역을 정확히 측정할 수 있지만 계산량이 많아 고사양의 시스템을 요구하고 스테레오 시스템 또한 고가이다. 따라서 본 논문에서는 단일 카메라 영상과 PSD(position sensitive device) 센서를 사용하여 SLAM을 구현하였다. 전방향의 PSD 센서로부터 일정 거리의 장애물을 감지하고 전면 카메라의 영상처리를 통해 장애물의 크기 및 특징을 감지한다. 위의 데이터를 통해 확률분포 SLAM을 구성하였고 실제 구현을 통해 성능검증을 하였다.

Ring Oscillator를 이용한 신호의 동시 스위칭 밀도 분석 (Analysis Simultaneously Switching Density Using Ring Oscillator)

  • 정상남;백상현
    • 대한전자공학회논문지SD
    • /
    • 제45권9호
    • /
    • pp.79-84
    • /
    • 2008
  • 기술의 발달과 함께 회로의 동작 주파수와 신호의 스위칭 속도가 증가하였다. 신호의 스위칭 밀도에 대하여 정확히 에측 할 수 있다면 보다 안정된 파워 플래인을 설계할 수 있다. 칩에서 예기치 못한 신호의 지연이 발생했을 때 문제를 해결하는데 많은 어려움이 있다. 파라서 회로를 수정하거나 칩의 특성을 정하는 단계에서 스위칭 밀도의 증가를 파악하는 것은 중요하다. 본 논문에서는 보간법을 이용하여 회로 설계단계에서 스위칭 밀도를 계산하는 방법을 제안했다. 여기서는 링 오실레이터의 스위칭 빈도와 신호의 지연 사이의 관계를 이용하여 보간법을 통해 신호의 스위칭 밀도를 계산하였다. 링 오실레이터는 스위칭이 많이 일어나서 신호의 지연이 축적된 후에 그라운드 바운스의 영향을 측정하기 위해 사용되었다. 실험은 동부 하이텍의 0.18um CMOS 공정 파리미터를 통해 진행하였다.

소나 기반 수중 로봇의 실시간 위치 추정 및 지도 작성에 대한 실험적 검증 (Experimental result of Real-time Sonar-based SLAM for underwater robot)

  • 이영준;최진우;고낙용;김태진;최현택
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.108-118
    • /
    • 2017
  • 본 논문은 수중 로봇 항법에 사용하기 위한 영상 소나 기반 SLAM (simultaneous localization and mapping) 방법을 제안하고, 성능 평가를 위해 실제 로봇에 탑재하여 실험한 내용을 소개한다. 일반적인 수중 항법은 관성 센서에서 출력되는 정보를 바탕으로 로봇의 위치 및 자세(x,y,z,${\phi}$,${\theta}$,${\psi}$)를 추정한다. 하지만, 장시간 주행할 경우 위치 오차의 누적으로 인하여 정확도가 감소하게 된다. 이에 본 논문에서는 영상 소나로부터 얻을 수 있는 외부 정보를 바탕으로 관성 항법의 위치 추정 성능을 높이고 지도 작성을 수행할 수 있는 SLAM 방법을 제안하고자 한다. 영상 소나를 위한 인공 표식물과 확률 기반 물체 인식 구조를 통해 인공 표식물의 인식 성능을 높이고, 이를 통해 얻게 된 인공 표식물의 위치 정보를 활용하여 관성 항법의 누적 오차를 줄이고자 한다. 항법 알고리즘으로는 확장형 칼만 필터(Extended Kalman Filter, EKF)를 적용하여 로봇의 위치 및 자세를 추정하고 지도를 작성한다. 제안한 방법은 선박해양플랜트연구소에서 보유 중인 수중 로봇 'yShark'에 탑재하여 대형 수조에서 실시간 검증을 수행하였다.

가정용 전자식 혈압계의 정확도에 대한 임상적 평가 (Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices)

  • 추진아
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

EMERGING POSSIBILITIES FOR NIRS TO CONTRIBUTO TO ENVIRONMENTAL ANALYSIS

  • Malley, Diane
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1071-1071
    • /
    • 2001
  • Near-infrared spectroscopy (NIRS) is potentially a powerful and revolutionary technology for environmental analysis. It is supported by a large body of scientific and experiential knowledge. The instrumentation is well-developed, with easy-to-use, highly dependable instruments, but at the same time it is still developing, particularly with the production of more portable and rapid instruments, and more powerful software. NIRS is used globally in numerous industries for commodity analysis. Yet NIRS is largely unknown in the field of environmental chemistry and monitoring, and is not even routinely used in soil analysis, where the research literature on NIRS extends over four decades. Part of the explanation for the poor visibility of NIRS is the fact that NIRS is not routinely taught in Chemistry programs in universities, where most environmental chemists and environmental technicians are trained. This presentation examines the unique capabilities of NIRS, such as rapid, real-time analysis; analysis of whole samples; simultaneous analysis of multiple constituents; cost-effectiveness, and portability, as they match needs for analysis in several environmental areas. Examples of NIRS usage and published and unpublished results will be described for such areas as soil and sediment analysis; water quality monitoring; and nutrient loading in application of manures and sewage sludge (biosolids) to land. Present barriers to the use of NIRS in environmental analysis will be discussed. It is argued that emerging environmental problems and increasing attention to some traditional problems will enhance the application of NIRS in the future.

  • PDF

Simultaneous Paraspinal and Midline Approach for Upper Lumbar Disc Herniation : Technique to Prevent Lamina Fracture

  • Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권2호
    • /
    • pp.111-115
    • /
    • 2005
  • Objective : Upper lumbar disc herniation is rare disease, compared with lower. The lamina of this high level lumbar vertebra is narrower than that of low level, and this have taken surgeon into important consideration for surgical methods because partial removal of lamina for discectomy weakens the base of the articular process and may result in fracture. The authors an accurate preoperative diagnosis that enables the surgeon to operative approach for preserving the facet joint. Methods : Thirteen patients with upper lumbar disc herniation have underone surgical procedure by midline approach for removal of ruptured disc fragment and paraspinal approach for removal of residual disc materials simultaneously without instrumentation. All patients who underwent surgery were analyzed and long-term follow-up was conducted. Results : At a mean follow-up of 24months, there were complete resolution of presenting radiating leg pain in 85% of the patients, 7.5% were left with minimal residual discomfort, and 7.5% derived little or no benefit from surgery. The follow-up radiologic findings of all patients shows that lamina and facet joint have preserved safely and no instability. Conclusion : Simultaneously, paraspinal with midline approach provides highly satisfactory operating methods by simplifying exposure and greatly limiting the risk of complications. This provides the basis for a planned surgical approach in which destruction of the facet joint can be avoided.

Nondestructive sensing technologies for food safety

  • Kim, M.S.;Chao, K.;Chan, D.E.;Jun, W.;Lee, K.;Kang, S.;Yang, C.C.;Lefcourt, A.M.
    • 한국환경농학회:학술대회논문집
    • /
    • 한국환경농학회 2009년도 정기총회 및 국제심포지엄
    • /
    • pp.119-126
    • /
    • 2009
  • In recent years, research at the Environmental Microbial and Food Safety Laboratory (EMFSL), Agricultural Research Service (ARS) has focused on the development of novel image-based sensing technologies to address agro-food safety concerns, and transformation of these novel technologies into practical instrumentation for industrial implementations. The line-scan-based hyperspectral imaging techniques have often served as a research tool to develop rapid multispectral methods based on only a few spectral bands for rapid online applications. We developed a newer line-scan hyperspectral imaging platform for high-speed inspection on high-throughput processing lines, capable of simultaneous multiple inspection algorithms for different agro-food safety problems such as poultry carcass inspection for wholesomeness and apple inspection for fecal contamination and defect detection. In addition, portable imaging devices were developed for in situ identification of contamination sites and for use by agrofood producer and processor operations for cleaning and sanitation inspection of food processing surfaces. The aim of this presentation is to illustrate recent advances in the above agro.food safety sensing technologies.

  • PDF

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF