• 제목/요약/키워드: Simultaneous Monitoring

검색결과 315건 처리시간 0.024초

대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가 (Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement)

  • 전의찬
    • 환경영향평가
    • /
    • 제5권1호
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

Simultaneous Monitoring of KVN 4 Bands toward Evolved Stars

  • Cho, Se-Hyung
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.112.2-112.2
    • /
    • 2014
  • We propose simultaneous monitoring observations of 22 GHz $H_2O$ and 43/86/129 GHz SiO masers toward ~15 evolved stars in order to investigate spatial structure and dynamical effect from SiO to $H_2O$ maser regions including mass-loss process and development of asymmetry in circumstellar envelopes. We also aim at investigating mutual association and difference between SiO and $H_2O$ masers for establishing SiO and $H_2O$ maser models coupled to hydrodynamical model of circumstellar envelope. In addition, the correlation and difference of SiO maser properties among J=1-0, J=2-1, and J=3-2 transition masers are traced according to different type of stars for constraining SiO pumping models. These scientific goals and target sources were determined based on KVN single dish and VLBI feasibility test observations at 4 bands. As a total observing time of every 2 month monitoring, about 90 and 360 hours (in average per year) are required for single dish and VLBI observations, respectively. From the 2014B observing season, these monitoring observations will be derived as one of KVN key science programs.

  • PDF

지하수 중 다환방향족탄화수소류(PAHs, Polycyclic Aromatic Hydrocarbons)의 동시분석법 마련 및 수질실태조사 (Preparation of Simultaneous Analysis Method of PAHs (Polycyclic Aromatic Hydrocarbons) and Monitoring PAHs in Groundwater)

  • 김덕현;박선화;윤종현;최효정;김문수;정도환;김영;김현구
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권4호
    • /
    • pp.67-76
    • /
    • 2020
  • Polycyclic aromatic hydrocarbons (PAHs) are organic compounds that tend to persist in environmental media for a long period of time. This work presents a 2-year monitoring study of occurrence of three PAHs (benzo(a)pyrene, naphthalene, and fluoranthene) in groundwater. The groundwater samples were collected from 106 sites of nation's groundwater quality monitoring network and analyzed by simultaneous analysis method to quantify the concentrations of the PAHs. Benzo(a)pyrene was not detected in all samples. Naphthalene and fluoranthene concentrations ranged from not detected to 12.8 ng/L and not detected to 10.5 ng/L with their detection frequency being 57.8 and 4.2%, respectively. The concentrations of PAHs in ground- and drinking waters are not currently regulated in Korea, but the concentration levels of naphthalene and fluoranthene found in this work were lower than the regulatory limits of other countries (naphthalene 0.001~0.07 mg/L, fluoranthene 0.001~1.4 mg/L). The monitoring result of this study revealed that PAHs exist as trace amounts in domestic groundwater, however continuos monitoring is necessary to protect groundwater from PAHs contamination with growing industrialization and urbanization.

A statistical quality control for the dispersion matrix

  • Jo, Jinnam
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권4호
    • /
    • pp.1027-1034
    • /
    • 2015
  • A control chart is very useful in monitoring various production process. There are many situations in which the simultaneous control of two or more related quality variables is necessary. When the joint distribution of the process variables is multivariate normal, multivariate Shewhart control charts using the function of the maximum likelihood estimator for monitoring the dispersion matrix are considered for the simultaneous monitoring of the dispersion matrix. The performances of the multivariate Shewhart control charts based on the proposed control statistic are evaluated in term of average run length (ARL). The performance is investigated in three cases, where the variances, covariances, and variances and covariances are changed respectively. The numerical results show that the performances of the proposed multivariate Shewhart control charts are not better than the control charts using the trace of the covariance matrix in the Jeong and Cho (2012) in terms of the ARLs.

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

Simultaneous Measurements of Gaseous Nitrous Acid and Particulate Nitrite Using Diffusion Scrubber/Steam Chamber/Luminol Chemiluminescence

  • Chang, Won-Il;Choi, Jung-Ho;Hong, Sang-Bum;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권8호
    • /
    • pp.1525-1532
    • /
    • 2008
  • An instrument was developed for the simultaneous determination of gas- and aerosol-phase nitrous acid (HONO). Gaseous HONO (HONO(g)) was sampled by a diffusion scrubber and particulate nitrite ($NO_2\;^-$(p)) was collected by a particle growth chamber. The collected samples were analyzed in time-sharing manner, based on the peroxynitrite-induced luminol chemiluminescence. The automated system was found to be sensitive with 13 pptv of detection limit, fast with 4 min. of sampling frequency, and simple and affordable to construct and operate. The system was optimized by adjusting the experimental parameters. The system was applied to the field measurement of gas- and particle-phase HONO during the springtime of 2004 in Gwangju, South Korea. HONO(g) concentrations varied diurnally from 200 pptv around 3 P.M. to 800 pptv at 5 A.M. The variation of $NO_2\;^-$(p) was not significant with the maximum of 240 pptv at 11 P.M. and the minimum of 170 pptv at 4 P.M., not displaying distinct characteristics.

복합재 주 날개 모델의 변형률과 진동의 동시 측정 (Simultaneous Measurement of Strain and High Frequency Vibration of Composite Main Wing Model)

  • 송지용;윤혁진;박상욱;박상오;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.185-189
    • /
    • 2005
  • For the simultaneous measurement of strain and vibration signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter could measure low-frequency signal such as strain and the other demodulator using a coarse wavelength division multiplexer could detect high-frequency signal such as vibration signal using intensity demodulation method. In order to measure strain and vibration of the composite main wing model under static loading a real time monitoring program was developed. Also using intensity demodulation of CWDM, sensitivity and resolution at high frequency vibration were evaluated.

  • PDF

토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구 (Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil)

  • 이승석;박교범;이성근
    • 대한화학회지
    • /
    • 제38권3호
    • /
    • pp.246-253
    • /
    • 1994
  • 미국 환경청이 지정한 129종의 priority pollutants 중 11종의 비휘발성 산성 유기화합물을 대상물질로 선정하여 토양시료 중의 극미량 분석방법을 연구하였다. 분석방법으로 기체크로토그래프/질량분석기- SIM(selected ion monitoring)법을 검출방법으로 정하고, 토양시료의 추출 및 농축방법으로 사용한 초음파 추출법(sonication extraction)과 Soxhlet(Soxhlet extraction)을 비교 연구하였다. 각 화합물의 회수율, 상대표준편차 및 method detection limit를 측정하여 EPA분석법을 대체할 수 있는지의 가능성을 조사하였다.

  • PDF

Development of a WLAN Based Monitoring System for Group Activity Measurement in Real-Time

  • Tsunoda, Hiroshi;Nakayama, Hidehisa;Ohta, Kohei;Suzuki, Akihiro;Nishiyama, Hiroki;Nagatomi, Ryoichi;Hashimoto, Kazuo;Waizumi, Yuji;Keeni, Glenn Mansfield;Nemoto, Yoshiaki
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.86-94
    • /
    • 2011
  • In recent years, there has been a rise in epidemiological evidence suggesting the health benefits of a physically active lifestyle. However, it is not always easy for individuals to personally recognize the optimal conditions for exercise and physical activity. Wearable acceleration-based pedometers have become widely used in estimating the amount of physical activity, and to a limited extent, providing information regarding exercise intensity, but they have never been used to assess adaptation to exercise. In order to realize simultaneous activity monitoring for multiple users exercising outdoors, we developed a prototype wireless local area network (WLAN) based system. In our system, a WLAN is deployed outside, and a user wearing a smart phone and monitoring device exercises freely within the coverage area of the wireless network. By doing so, the developed system is able to monitor the activity of each user andmeasures various parameters including those related to exercise adaptation. In a demonstration experiment, the developed system was evaluated and used to monitor users enjoying a Nordic walk, after which users were immediately able to receive their exercise report. In this paper, we discuss the requirements and issues in developing an activity monitoring system and report the findings we obtained through the demonstration experiment.