• Title/Summary/Keyword: Simultaneous Measurement

Search Result 484, Processing Time 0.027 seconds

A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구)

  • Lee, Won;Hur, Young-Hoe;Park, Kyung-Su
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.281-291
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in blood and urine has been investigated by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Microwave oven was used for the pretreatment of blood samples using nitric acid and hydrogen peroxide in a closedvessel digestion system with 1 mL whole blood for 8 minutes. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Detection limits for Cu, Sn, and Bi by this method were 0.000375 ng/mL, 0.000297 ng/mL, and 0.000174 ng/mL, respectively. Recoveries of 99.1% for Cu, 102.5% for Sn, and 98.4% for Bi were obtained for the standard spiked NIST SRM 955a blood sample. The developed method was applied for whole real blood and urine samples.

  • PDF

A Study on Antecedents of Online Trust in the Context of e-Government Services (전자정부 서비스 사용에 있어 온라인 신뢰에 관한 연구)

  • Moon, Chul-Woo;Kim, Jae-Hyoun
    • Journal of Internet Computing and Services
    • /
    • v.12 no.3
    • /
    • pp.57-67
    • /
    • 2011
  • Trust is generally assumed to be an important precondition for people's adoption of e-government services. This study analyzes the direct and indirect impact of information privacy, interactivity, subjective norms and words-of-mouth on perceived trust of e-government services and trust toward government. The Partial Least Square(PLS) was applied to the citizen survey data for hypotheses testing. PLS permits the simultaneous testing of cause-effect hypotheses while also allowing evaluation of the measurement model. Statistical results indicate that interactivity, subjective norms and words-of-mouth positively affects perceived trust of e-government services, which in turn affects the level of political efficacy and the trust toward the government. Interactivity has been found to affect words-of-mouth as well. However, information privacy has no significant effect on the trust of e-government services.

Simultaneous Observation of FUV Aurora with Precipitating Electrons on STSAT-1

  • Lee, C.N.;Min, K.W.;Lee, J.J.;Kim, K.H.;Kim, Y.H.;Han, W.;Edelstein, J.
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.31.2-31.2
    • /
    • 2008
  • We present the results offar ultraviolet (FUV, 1350-1750 ${\AA}$) auroral observations made by the Far-ultraviolet IMaging Spectrograph (FIMS) instrument on the Korean microsatellite STSAT-1. The instrument was capable of resolving spatial structures of a few kilometers with the spectral resolution of 2-3 ${\AA}$. The observations were carried out simultaneously with the measurement of precipitating electrons using an electrostatic analyzer (ESA, 100 eV-20 keV) and a solid state telescope (SST, 170 keV-360 keV) on board the same satellite. With a careful mapping of the field lines, we were able to correlate the particle spectrum to the corresponding FUV spectrum of the footprints of the FIMS image that varied significantly in fine scales. We divided the FIMS spectral band into the LBH long (LBHL, 1640-1715 ${\AA}$) and LBH short (LBHS, 1380-1455 ${\AA}$) bands, and compared the electron energies with the intensities of LBHL and LBHS for the well-defined inverted-V structures. The result shows a strong correlation between the total LBH intensity and the energy flux measured by ESAwhile the peak energy itself does not correlate well with the LBH intensity. On the other hand, it was observed that the ratio of the LBHL intensity to that of LBHS increased significantly as the peak electron energy increased, primarily due to a smaller absorption by O2 at LBHL than at LBHS.

  • PDF

Simultaneous imaging and radiometric performance simulation for computer generated GOCI optical system with measured characteristics

  • Jeong, Soo-Min;Jeong, Yu-Kyeong;Ryu, Dong-Ok;Yoo, Jin-Hee;Kim, Seong-Hui;Cho, Seong-Ick;Ham, Sun-Jeong;Youn, Heong-Sik;Woo, Sun-Hee;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.3-28
    • /
    • 2008
  • In this study, we report a new Monte Carlo ray tracing technique for estimating GOCI (Geostationary Ocean Color Instrument) radiative transfer characteristics and imaging performance simultaneously. First, a full scale GOCI optical model was constructed with measured characteristics at the component level and placed in the geostationary orbit. An optical model of approximated GOCI target area centered at the Korean penninsular was then built using the USGS coastal line data and representative land and sea surface reflectivity data. The light rays launched from a simulated sun model travel to the Earth surface, where they are reflected and scattered. Some of the light rays that are headed to the GOCI model in the orbit were selected and traced, as they have entered into the GOCI aperture. As they pass through each GOCI optical part, the ray path and intensity are adjusted according to the measured characteristics for reflection, transmission, refractive index and surface scattering. The ray-traced imaging and radiative transfer performance indicators confirm that the computer generated GOCI optical system with measured characteristics can be used for in-orbit operation simulation following the designed measurement sequence. The computational technique and its implications as a operation support tool are discussed.

  • PDF

Maritime Atmospheric Boundary Layer Observed By L-band Doppler radar (도플러 레이더를 이용한 해안지역의 대기경계층 분석 연구)

  • Kwon, Byung-Hyuk;Yoon, Hong-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.977-984
    • /
    • 2000
  • Atmospheric boundary layer over equatorial maritime continent was analyzed with Doppler radar. An L-band (1357.5 MHz) boundary layer radar (BLR) has been in continuous successful operation in Selpong, Indonesia(6.45, 106.7E), since November 1992. The performance of the BLR with respect to the observation height range and the wind measurement reliability has been examined on the basis of simultaneous meteorological observations. In the dry season (10-12 October 1993), we have found two types of strong echo structures appearing systematically in the equatorial planetary boundary layer with diurnal variations on clear days. The first type is the striking appearance of a strong echo layer ascending from below 300 m (in the morning) to above 3-5 km (in the afternoon), which is identified with a diurnal variation of the top of the mixing planetary boundary layer. As expected, it is higher in the Indonesian equatorial region than in midlatitudes. Another type is a layered echo appearing at 2-3 km heights from nighttime to morning, which seem to be coincident with humidity gaps. In the rainy season (20-21 February 1994), the height of the atmospheric mining was lower than that in the dry season.

  • PDF

Measurement of Hydrogen Crossover by Gas Chromatograph in PEMFC (고분자전해질 연료전지에서 기체 크로마토그래프에 의한 수소투과도 측정)

  • Jeong, Jaejin;Jeong, Jaehyeun;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2014
  • Until a recent day, degradation of PEMFC MEA(membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. Hydrogen permeability was used often to measure degradation of electrolyte membrane in PEMFC. In case of hydrogen permeability measured by LSV(Linear Sweep Voltammetry) method, the degradation of electrode decrease the value of hydrogen crossover current due to LSV methode's dependence on electrode active area. In this study hydrogen permeability was measured by gas chromatograph(GC) when membrane and electrode degraded at the same time. It was showed that degradation of electrode did not affect the hydrogen permeability measured by GC because of GC methode's independence on electrode active area.

An Effectiveness of Simultaneous Measurement of PM10, PM2.5, and PM1.0 Concentrations in Asian Dust and Haze Monitoring

  • Cho, Changbum;Park, Gilun;Kim, Baekjo
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.651-666
    • /
    • 2013
  • This study introduces a novel approach to the differentiation of two phenomena, Asian Dust and haze, which are extremely difficult to distinguish based solely on comparisons of PM10 concentration, through use of the Optical Particle Counter (OPC), which simultaneously generates PM10, PM2.5 and PM1.0 concentration. In the case of Asian Dust, PM10 concentration rose to the exclusion of PM2.5 and PM1.0 concentration. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were below 40%, which is consistent with the conclusion that Asian Dust, as a prime example of the coarse-particle phenomenon, only impacts PM10 concentration, not PM2.5 and PM1.0 concentration. In contrast, PM10, PM2.5 and PM1.0 concentration simultaneously increased with haze. The relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration were generally above 70%. In this case, PM1.0 concentration varies because a haze event consists of secondary aerosol in the fine-mode, and the relative ratios of PM10 and PM2.5 concentration remain intact as these values already subsume PM1.0 concentration. The sequential shift of the peaks in PM10, PM2.5 and PM1.0 concentrations also serve to individually track the transport of coarse-mode versus fine-mode aerosols. The distinction in the relative ratios of PM2.5 and PM1.0 concentration versus PM10 concentration in an Asian Dust versus a haze event, when collected on a national or global scale using OPC monitoring networks, provides realistic information on outbreaks and transport of Asian Dust and haze.

Evaluation of factors influencing the success rate of orthodontic microimplants using panoramic radiographs

  • Park, Jae Hyun;Chae, Jong-Moon;Bay, R. Curtis;Kim, Mi-Jung;Lee, Keun-Young;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.48 no.1
    • /
    • pp.30-38
    • /
    • 2018
  • Objective: The purpose of this study was to investigate factors influencing the success rate of orthodontic microimplants (OMIs) using panoramic radiographs (PRs). Methods: We examined 160 OMIs inserted bilaterally in the maxillary buccal alveolar bone between the second premolars and first molars of 80 patients (51 women, 29 men; mean age, $18.0{\pm}6.1years$) undergoing treatment for malocclusion. The angulation and position of OMIs, as well as other parameters, were measured on PRs. The correlation between each measurement and the OMI success rate was then evaluated. Results: The overall success rate was 85.0% (136/160). Age was found to be a significant predictor of implant success (p < 0.05), while sex, side of placement, extraction, and position of the OMI tip were not significant predictors (p > 0.05). The highest success rate was observed for OMIs with tips positioned on the interradicular midline (IRML; central position). Univariate analyses revealed that the OMI success rate significantly increased with an increase in the OMI length and placement height of OMI (p = 0.001). However, in simultaneous analyses, only length remained significant (p = 0.027). Root proximity, distance between the OMI tip and IRML, interradicular distance, alveolar crest width, distance between the OMI head and IRML, and placement angle were not factors for success. Correlations between the placement angle and all other measurements except root proximity were statistically significant (p < 0.05). Conclusions: Our findings suggest that OMIs positioned more apically with a lesser angulation, as observed on PRs, exhibit high success rates.

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

The Characteristics Analysis of GIDL current due to the NBTI stress in High Speed p-MOSFET (고속용 p-MOSFET에서 NBTI 스트레스에 의한 GIDL 전류의 특성 분석)

  • Song, Jae-Ryul;Lee, Jong-Hyung;Han, Dae-Hyun;Lee, Yong-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.348-354
    • /
    • 2009
  • It has analyzed that the device degradation by NBTI (Negative Bias Temperature Instability) stress induced the increase of gate-induced-drain-leakage(GIDL) current for p-MOSFETs. It is shown that the degradation magnitude, as well as its time, temperature, and field dependence, is govern by interface traps density at the silicon/oxide interface. from the relation between the variation of threshold voltage and subthreshold slope, it has been found that the dominant mechanism for device degradation is the interface state generation. From the GIDL measurement results, we confined that the EHP generation in interface state due to NBTI stress led to the increase of GIDL current. Therefore, one should take care of the increased GIDL current after NBTI stress in the ultra-thin gate oxide device. Also, the simultaneous consideration of reliability characteristics and dc device performance is highly necessary in the stress engineering of nanoscale CMOSFETs.