• Title/Summary/Keyword: Simultaneous Measurement

Search Result 484, Processing Time 0.039 seconds

The Review of Instrumental Neutron Activation Analysis by $k_0$-standardization method ($k_0$-표준화방법에 의한 기기중성자방사화 분석법의 고찰)

  • Moon, Jong-Hwa;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.1075-1081
    • /
    • 2001
  • Instrumental Neutron Activation Analysis as a representative method of nuclear analytical technique, has advantages of non-destructive, simultaneous multi-element analysis with the characteristics of absolute measurement method. Up to date, $k_0$-quantitative method which is accurate, convenient and user-friendly, has been generalized world-widely. In this study, it is intented to introduce the general concept of $k_0$-method and to measure $k_0$-parameters for the future implementation to our NAA system. For this objectives, the definition of relevant factors for the quantitative analysis and the equation for the experimental determination of parameters such as $Q_0$(${\alpha}$) and f were summarized. Furthermore, a foundation for the $k_0$-standardization method was prepared through the measurement of ${\alpha}$ and f-value which depend on the specific character of irradiation hole at NAA#1-hole of HANARO research reactor.

  • PDF

Simple and Robust Measurement of Blood Plasma Lysophospholipids Using Liquid Chromatography Mass Spectrometry

  • Ji, Dong Yoon;Lee, Chang-Wan;Park, Se Hee;Lee, Eun Jig;Lee, Do Yup
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.109-113
    • /
    • 2017
  • Single analytical procedure including extraction, liquid chromatography, and mass spectrometric analysis was evaluated for the simultaneous measurement of lysophospholipids (LPLs). LPLs, particularly, lysophosphatidic acids (LPA) and sphingosine 1-phosphate (S1P) are lipid messengers ubiquitously found in various biological matrix. The molecular species mediate important physiological roles in association with many diseases (e.g. cancer, inflammation, and neurodegenerative disease), which emphasize the significance of the simple and reliable analytical method for biomarker discovery and molecular mechanistic understanding. Thus, we developed analytical method mainly focusing on, but not limited by those lipid species S1P and LPA using reverse phase liquid chromatography-tandem mass spectrometry (RPLC-ESI-MS-MS). Extraction method was modified based on Folch method with optimally minimal level of ionization additive (ammonium formate 10 mM and formic acid). Reverse-phase liquid-chromatography was applied for chromatographical separation in combination with negative ionization mode electrospray-coupled Orbitrap mass spectrometry. The method validation was performed on human blood plasma in a non-targeted lipid profiling manner with full-scan MS mode and data-dependent MS/MS. The proposed method presented good inter-assay precision for primary targets, S1P and LPA. Subsequent analysis of other types of LPLs identified a broad range of lysophosphatidylcholines (LPCs) and lysophosphatidyl-ethanolamines (LPEs).

Developments of Hormone Assays, Second Generation: Non-Isotopic Immunoassays (호르몬 측정법의 발달 제 2세대: 비방사면역측정법)

  • Lee, Chang-Joo;Kim, Sang Soo;Yoon, Yong-Dal
    • Development and Reproduction
    • /
    • v.9 no.2
    • /
    • pp.65-83
    • /
    • 2005
  • The three important phases in the development of ligand immunoassays are identified and summarized. The competitive radiolabelled hormone measurement had been developed in the first and early in the second generations(1950s to 1960s), such as radioimmunoassays(RIA) or immunoradiometric(saturation) assays(IRMA), and used in all most of the hormone and also analyte in biological samples. In the second generation, ultrasensitive non-isotopic immunoassays(NIA) were developed using monoclonal antibodies(McAb), labelling the McAb and high specific activity non-isotopic labels. After their usefulness, advantages and disadvantages has been evaluated and non-competitive methods are discussed. The chip/microarray based multianalyte ligand assays(microspot or genechip methods) are developed and known as alternative ones in the third generation. We summarize the developments of NIAs and its usefulness, and then introduce briefly the new ligand assays.

  • PDF

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Vortex dynamics in YBa$_2Cu_3O_7$ single crystals measured by micro Hall-probe array (Micro Hall probe array를 이용한 YBa$_2Cu_3O_7$ 단결정 내부의 자속 운동 측정)

  • Shim, Seong-Yeop;Hwang, Hyeon-Guk;Lee, Chang-Woo;Lee, Tae-Won;Kim, Dong-Ho
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.189-195
    • /
    • 1999
  • We have studied the vortex dynamics in YBa$_2Cu_3O_7$ single crystals with columnar defects using micro Hall-probe array. The Hall-probe array technique allowed a simultaneous measurement of the time and spatial dependence of the vortex density so that more detailed information on flux dynamics could be obtained. We found that field profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. Normalized relaxation rates were maximum near the center and decreased toward the edge if applied field H$_{app}$ is greater than the penetration field H. But applied magnetic field H$_{app}$ is less than H, relaxation rates were minimum near the center and increased toward edge. We found that glassy exponent ${\mu}$ has the value of ${\sim}$ 1 whose corresponding vortex motion is half-loop excitation. However, single vortex creep, ${\mu}$ ${\sim}$ 1/7, was also found at 30 K and H$_{app}$ ${\cong}$ H'. Calculation of activation energy, U, was possible from direct analysis of the local relaxation data using the basic diffusion equation. From these results, we found that U increases logarithmically with time and U around center was lower than that at the edge.

  • PDF

X-RAY PHOTOELECTRON SPECTOSCOPIC ANALYSIS OF ALUMINUM COMPOUND ADSORBED ON PULP FIBER SURFACES

  • Takuya Kitaoka;Hiroo Tanaka
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.239-244
    • /
    • 1999
  • aluminum sulfate (alum) as a representative retention aid in papermaking processes was added to pulp suspensions, and the aluminum components adsorbed on the pulp were investigated quantitatively by two types of X-ray elementary analyses with regard to simultaneous changes of their surface charges. X-ray photoelectron spectroscopy (XPS) and X-ray fluorescence analysis (XFA) were applied to determine the aluminum components retained in pulp pads up to ca. 10 nm and 100${\mu}$m depth, respectively. In other words, XPS was utilized to analyze the outermost surface layers of the samples, and XFA was available for measurement of their extensive regions. A particle charge detector (PCD) was used to monitor streaming potentials at various pHs of the pulp mixtures under moderate sharing conditions. At pH 4.5 of pulp suspensions containing alum, surface charges of pulp fibers varied from negative to slight negative (approximately neutral) according to adsorption of aluminum components onto the pulp fibers. Subsequently, when a dilute NaOH solution in limited amounts was added to pulp mixtures, both streaming potentials and surface aluminum content of the pulp fibers increased distinctly although little total aluminum retention increased. Further addition of alkali solutions brought drastic decreases of the surface charges and surface aluminum content, while total aluminum content, on the contrary, increased gradually under neutral conditions. These results indicate that residual aluminum ions remained in pulp suspensions are predominantly adsorbed on surfaces of pulp fibers by adequate alkali additions and they must sufficiently cationize the fiber surfaces with increases of somewhat cationic aluminum complexes formed on the surfaces. On the other hand, aluminum components formed in higher pH ranges have nearly no contribution to improvement of charge properties of the pulp fiber surfaces, even though aluminum retention in pulp pads increases. XPS and XFA analyses combined with streaming potential measurement using a PCD suggest close relationships between aluminum content on the pulp fiber surfaces and their charge properties.

Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere - Focusing on High Volume Sampling and GC/MS Analysis (대기 중 다환방향족탄화수소 측정방법의 성능평가 - 하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로)

  • Seo, Young-Kyo;Park, Dae-Kwon;Baek, Sung-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.322-333
    • /
    • 2009
  • In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on $8"{\times}10"$ quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.

Measurement of CTE Change in a Composite Laminate with Aging under Space Environment using Fiber Optic Sensors (광섬유센서를 이용한 우주환경하에서 복합재료 적층시편의 노화에 따른 열팽창계수변화 측정)

  • Gang,Sang-Guk;Gang,Dong-Hun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.21-26
    • /
    • 2003
  • In this research, the change of coefficient of thermal expansion (CTE) of graphite/epoxy composite laminate under space environment was measured using fiber optic sensors. Two fiber Bragg grating (FBG) sensors have been adopted for the simultaneous measurement of thermal strain and temperature. Low Earth Orbit (LEO) conditions with high vacuum, ultraviolet and thermal cycling environments were simulated in a thermal vacuum chamber. As a pre-test, a FBG temperature sensor was calibrated and a FBG strain sensor was verified through the comparison with the electric strain gauge (ESG) attached on an aluminun specimen at high and low temperature respectively. The change of the CTE in a composite laminate exposed to space environment was measured for intervals of aging cycles in real time. As a whole, there was no abrupt change of the CTE after 1000 aging cycles. After aging, however, the CTE decreased a Little all over the test temperature range. These changes are caused by outgassing, moisture desorption, matrix cracking etc.

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Design of Oriental Medicine diagnosis system by Bio-Electric Response (생체-전기적 반응에 의한 한의학적 진단시스템의 설계)

  • 이용흠;장근중;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.420-429
    • /
    • 2004
  • It has been needed diagnosis technology of the EFG(Electro Functio Gram) measurement concept which is incorporated characteristic of modern science and biomedical engineering, because function abnormality diagnosis can't diagnose with visualization instruments or clinical pathology. The general diagnosis system(EFG system) has been developed to use basic diagnosis instrument that has reappearance, reliance and convenience using the functio diagnosis technology, in the field of western/oriental medicine. Also, we improved sticking electrode and simultaneous measurement method of the limbs 8CH, head 2CH to diagnose body circulation of Qi and acupoints for Oriental Medicine diagnosis/therapy. The result of clinical for adult man 20 persons, the EFG system can diagnose state of 12 meridians and autonomic nervous system. Therefore, in this paper, we designed of oriental medicine diagnosis system by bio-electric response with materialized H/W and S/W for 12 meridians state diagnosis of human body and system construction of the EFG.