• Title/Summary/Keyword: Simultaneous Measurement

Search Result 488, Processing Time 0.025 seconds

Simultaneous Determiniation of Ar/$N_2$Ratios in Groundwater (지하수에 용해된 질소, 아르곤 가스의 동시측정)

  • Kim, Euisik;Roy F. Spalding
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 1994
  • Previously reported Ar/N$_2$ratios in groundwater have been measured by single ion monitoring (Barnes et al., 1975; Vogel et al., 1981; Mariotti et al., 1988). The detector geometry and flared flight tube in VG Optima isotopic ratio mass spectrometer appeared to be fortuitously aligned for the simultaneous measurement of Ar/N$_2$ratios. Method development included mechanical adjustments to optimize the mass spectrometer for Ar/N$_2$ratio measurements followed by development of a preparation system for the extraction of air-saturated water samples. Samples containing known Ar/N$_2$ratios were used to assess accuracy and precision, and to test the applicability of methods for measurements of aqueous Ar/N$_2$ratios. The results indicated that the prepared air-saturated water samples were almost identical to the predicted Ar/N$_2$ratios (p <0.001). Groundwater samples were collected from on-going research sites, Shelton and Grand Island, Nebraska. Samples from the Grand Island sludge injection site form a lower boundary for worldwide reported Ar/N$_2$ratios. These lower Ar/N$_2$ratios can be explained by the production of nitrogen gas from this site, where denitrification was reported previously.

  • PDF

Analysis of Instability Mechanism under Simultaneous Positive Gate and Drain Bias Stress in Self-Aligned Top-Gate Amorphous Indium-Zinc-Oxide Thin-Film Transistors

  • Kim, Jonghwa;Choi, Sungju;Jang, Jaeman;Jang, Jun Tae;Kim, Jungmok;Choi, Sung-Jin;Kim, Dong Myong;Kim, Dae Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.526-532
    • /
    • 2015
  • We quantitatively investigated instability mechanisms under simultaneous positive gate and drain bias stress (SPGDBS) in self-aligned top-gate amorphous indium-zinc-oxide thin-film transistors. After SPGDBS ($V_{GS}=13V$and $V_{DS}=13V$), the parallel shift of the transfer curve into a negative $V_{GS}$ direction and the increase of on current were observed. In order to quantitatively analyze mechanisms of the SPGDBS-induced negative shift of threshold voltage (${\Delta}V_T$), we experimentally extracted the density-of-state, and then analyzed by comparing and combining measurement data and TCAD simulation. As results, 19% and 81% of ${\Delta}V_T$ were taken to the donor-state creation and the hole trapping, respectively. This donor-state seems to be doubly ionized oxygen vacancy ($V{_O}^{2+}$). In addition, it was also confirmed that the wider channel width corresponds with more negative ${\Delta}V_T$. It means that both the donor-state creation and hole trapping can be enhanced due to the increase in self-heating as the width becomes wider. Lastly, all analyzed results were verified by reproducing transfer curves through TCAD simulation.

Experimental result of Real-time Sonar-based SLAM for underwater robot (소나 기반 수중 로봇의 실시간 위치 추정 및 지도 작성에 대한 실험적 검증)

  • Lee, Yeongjun;Choi, Jinwoo;Ko, Nak Yong;Kim, Taejin;Choi, Hyun-Taek
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.108-118
    • /
    • 2017
  • This paper presents experimental results of realtime sonar-based SLAM (simultaneous localization and mapping) using probability-based landmark-recognition. The sonar-based SLAM is used for navigation of underwater robot. Inertial sensor as IMU (Inertial Measurement Unit) and DVL (Doppler Velocity Log) and external information from sonar image processing are fused by Extended Kalman Filter (EKF) technique to get the navigation information. The vehicle location is estimated by inertial sensor data, and it is corrected by sonar data which provides relative position between the vehicle and the landmark on the bottom of the basin. For the verification of the proposed method, the experiments were performed in a basin environment using an underwater robot, yShark.

Management of Defects on Lower Extremities with the Use of Matriderm and Skin Graft

  • Choi, Jun-Young;Kim, Seong-Hun;Oh, Gwang-Jin;Roh, Si-Gyun;Lee, Nae-Ho;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.337-343
    • /
    • 2014
  • Background The reconstruction of large skin and soft tissue defects on the lower extremities is challenging. The skin graft is a simple and frequently used method for covering a skin defect. However, poor skin quality and architecture are well-known problems that lead to scar contracture. The collagen-elastin matrix, Matriderm, has been used to improve the quality of skin grafts; however, no statistical and objective review of the results has been reported. Methods Thirty-four patients (23 male and 11 female) who previously received a skin graft and simultaneous application of Matriderm between January 2010 and June 2012 were included in this study. The quality of the skin graft was evaluated using Cutometer, occasionally accompanied by pathologic findings. Results All 34 patients showed good skin quality compared to a traditional skin graft and were satisfied with their results. The statistical data for the measurement of the mechanical properties of the skin were similar to those for normal skin. In addition, there was no change in the engraftment rate. Conclusions The biggest problem of a traditional skin graft is scar contracture. However, the dermal matrix presents an improvement in skin quality with elastin and collagen. Therefore, a skin graft along with a simultaneous application of Matriderm is safe and effective and leads to a significantly better outcome from the perspective of skin elasticity.

Carbamate-Based Surface Reactions for Release of Amine Molecules from Electroactive Self-Assembled Monolayers

  • Hong, Dae-Wha;Kang, Kyung-Tae;Hong, Seok-Pyo;Shon, Hyun-Kyong;Lee, Tae-Geol;Choi, In-Sung S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.208-209
    • /
    • 2011
  • In this work, we developed self-assembled monolayers (SAMs) of alkanethiols on gold that can release amine groups, when an electrical potential was applied to the gold. The strategy was based on the introduction of the electroactive carbamate group, which underwent the two-electron oxidation with simultaneous release of the amine molecules, to alkanethiols. The synthesis of the designed thiol compounds was achieved by coupling isocyanate-containing compound with hydroquinone. The electroactive thiols were mixed with hydroxyl-containing alkanethiol [$HS(CH_2)_{11}OH$] to form mixed monolayers, and cyclic votammetry was used for the characterization of the release. The mixed SAMs showed a first oxidation peak at +540 mV (versus Ag/AgCl reference electrode), demonstrating irreversible conversion from carbamate to hydroqinone with simultaneous release of the amine groups. The second and third cycles showed typical reversible redox reaction of hydroquinone and quione: the oxidation and reduction occurred at +290 mV and -110 mV, respectively. The measurement of ToF-SIMS further indicates that electrochemical-assisted chemical reaction successfully released amine groups. This new SAM-based electrochemistry would be applicable for direct release of biologically active molecules that contain amine groups.

  • PDF

Improvement of SLAM Using Invariant EKF for Autonomous Vehicles (Invariant EKF를 사용한 자율 이동체의 SLAM 개선)

  • Jeong, Da-Bin;Ko, Nak-Yong;Chung, Jun-Hyuk;Pyun, Jae-Young;Hwang, Suk-Seung;Kim, Tae-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.237-244
    • /
    • 2020
  • This paper describes an implement of Simultaneous Localization and Mapping(SLAM) in two dimensional space. The method uses Invariant Extended Kalman Filter(IEKF), which transforms the state variables and measurement variables so that the transformed variables constitute a linear space when variables called the invariant quantities are kept constant. Therefore, the IEKF guarantees convergence provided in the invariant quantities are kept constant. The proposed IEKF approach uses Lie group matrix for the transformation. The method is tested through simulation, and the results show that the Kalman gain is constant as it is the case for the linear Kalman filter. The coherence between the estimated locations of the vehicle and the detected objects verifies the estimation performance of the method.

Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement (시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어-)

  • Moon, Se-Heum;Jeong, Jae-Hong;Lee, Seung-Hoon;Lee, Seung-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.897-900
    • /
    • 2008
  • Some substances of cement could make underestimate concentration of hexavalent chromium(Cr(VI)) as they reduce Cr(VI) to Cr(III) in acidic condition during the determination of Cr(VI) content in cement. The reduction of Cr(VI) increased with elapsed time after acidification in this study. The reduction rate varied with various cements. From our result, we can conclude that simultaneous additions of acid and DPC were required for the accurate measurement of Cr(VI) in cement. The high recovery rate of 94.3 to 106.7% with the simultaneous acid-DPC addition method can also support our conclusion.

  • PDF

Development of a WLAN Based Monitoring System for Group Activity Measurement in Real-Time

  • Tsunoda, Hiroshi;Nakayama, Hidehisa;Ohta, Kohei;Suzuki, Akihiro;Nishiyama, Hiroki;Nagatomi, Ryoichi;Hashimoto, Kazuo;Waizumi, Yuji;Keeni, Glenn Mansfield;Nemoto, Yoshiaki
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.86-94
    • /
    • 2011
  • In recent years, there has been a rise in epidemiological evidence suggesting the health benefits of a physically active lifestyle. However, it is not always easy for individuals to personally recognize the optimal conditions for exercise and physical activity. Wearable acceleration-based pedometers have become widely used in estimating the amount of physical activity, and to a limited extent, providing information regarding exercise intensity, but they have never been used to assess adaptation to exercise. In order to realize simultaneous activity monitoring for multiple users exercising outdoors, we developed a prototype wireless local area network (WLAN) based system. In our system, a WLAN is deployed outside, and a user wearing a smart phone and monitoring device exercises freely within the coverage area of the wireless network. By doing so, the developed system is able to monitor the activity of each user andmeasures various parameters including those related to exercise adaptation. In a demonstration experiment, the developed system was evaluated and used to monitor users enjoying a Nordic walk, after which users were immediately able to receive their exercise report. In this paper, we discuss the requirements and issues in developing an activity monitoring system and report the findings we obtained through the demonstration experiment.

A Study on Simultaneous Adjustment of GNSS Baseline Vectors and Terrestrial Measurements

  • Nguyen, Dinh Huy;Lee, Hungkyu;Yun, Seonghyeon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.415-423
    • /
    • 2020
  • GNSS (Global Navigation Satellite System) is mostly used for high-precise surveys due to its accuracy and efficiency. But this technique does not always fulfill the demanding accuracy in harsh operational environments such as urban canyon and forest. One of the remedies for overcoming this barrier is to compose a heterogeneous surveying network by adopting terrestrial measurements (i.e., distances and angles). Hence, this study dealt with the adjustment of heterogeneous surveying networks consisted of GNSS baseline vectors, distances, horizontal and vertical angles with a view to enhancing their accuracy and so as to derive an appropriate scheme of the measurement combination. Reviewing some technical issues of the network adjustments, the simulation, and experimental studies have been carried out, showing that the inclusion of the terrestrial measurements in the GNSS standalone overall increased the accuracy of the adjusted coordinates. Especially, if the distances, the horizontal angles, or both of them were simultaneously adjusted with GNSS baselines, the accuracy of the GNSS horizontal component was improved. Comparing the inclusion of the horizontal angles with those of the distances, the former has been more influential on accuracy than the latter even though the same number of measurements were employed in the network. On the other hand, results of the GNSS network adjustment together with the vertical angles demonstrated the enhancement of the vertical accuracy. As conclusion, this paper proposes a simultaneous adjustment of GNSS baselines and the terrestrial measurements for an effective scheme that overcomes the limitation of GNSS control surveys.

Automation of urine dipstick test by simultaneous scanning : A pilot study (요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구)

  • Lee, Sang-Bong;Choi, Seong-Su;Lee, In-Kwang;Han, Jeong-Su;Kim, Wan-Seok;Kim, Wun-Jae;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.169-175
    • /
    • 2010
  • Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.