• Title/Summary/Keyword: Simulated Signal Generator

Search Result 58, Processing Time 0.03 seconds

A Study on the Detection Algorithm of Series Arc Signals in Air Conditioners (에어컨에서 직렬아크검출 알고리즘에 관한 연구)

  • Ji, Hong-Keun;Choi, Sung-Kuk;Jung, Kwang-Seok;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1970-1976
    • /
    • 2009
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 170 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF

A Novel RGB Image Steganography Using Simulated Annealing and LCG via LSB

  • Bawaneh, Mohammed J.;Al-Shalabi, Emad Fawzi;Al-Hazaimeh, Obaida M.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.1
    • /
    • pp.143-151
    • /
    • 2021
  • The enormous prevalence of transferring official confidential digital documents via the Internet shows the urgent need to deliver confidential messages to the recipient without letting any unauthorized person to know contents of the secret messages or detect there existence . Several Steganography techniques such as the least significant Bit (LSB), Secure Cover Selection (SCS), Discrete Cosine Transform (DCT) and Palette Based (PB) were applied to prevent any intruder from analyzing and getting the secret transferred message. The utilized steganography methods should defiance the challenges of Steganalysis techniques in term of analysis and detection. This paper presents a novel and robust framework for color image steganography that combines Linear Congruential Generator (LCG), simulated annealing (SA), Cesar cryptography and LSB substitution method in one system in order to reduce the objection of Steganalysis and deliver data securely to their destination. SA with the support of LCG finds out the optimal minimum sniffing path inside a cover color image (RGB) then the confidential message will be encrypt and embedded within the RGB image path as a host medium by using Cesar and LSB procedures. Embedding and extraction processes of secret message require a common knowledge between sender and receiver; that knowledge are represented by SA initialization parameters, LCG seed, Cesar key agreement and secret message length. Steganalysis intruder will not understand or detect the secret message inside the host image without the correct knowledge about the manipulation process. The constructed system satisfies the main requirements of image steganography in term of robustness against confidential message extraction, high quality visual appearance, little mean square error (MSE) and high peak signal noise ratio (PSNR).

A Study on the Series Arc Detection in Low-voltage Wiring Systems (저압배선계통에서 직렬아크의 검출에 관한 연구)

  • Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Park, Chan-Yong;Kim, Hwang-Kuk;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

Three-Phase Reference Current Generator Employing with Kalman Filter for Shunt Active Power Filter

  • Hasim, Ahmad Shukri Abu;Ibrahim, Zulkifilie;Talib, Md. Hairul Nizam;Dardin, Syed Mohd. Fairuz Syed Mohd.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.151-160
    • /
    • 2017
  • This paper presents a new technique of reference current generator based on Kalman filter (KF) estimator for three-phase shunt active power filter (APF). The stationary reference frame (d-q algorithm) is used to transform the load currents into DC component. The harmonics of load currents are extracted and the three-phase reference currents are generated using KF estimator. The work is simulated using Matlab/Simulink platform. To validate the simulation results, an experimental test-rig have been perform using real-time control dSPACE DS1104. In addition, hysteresis current control was used to generate the switching signal for the correction of the harmonics in the system. The non-linear load were constructed with three-phase rectifier which connected in series with inductor and parallel with resistor and capacitor. The results shows that the new technique of shunt APF embedded with KF is proven to eliminate the harmonics created by the non-linear load with some improvement on the total harmonics distortion (THD).

Reliability Evaluation of the Partial Discharge Measuring Sensor for Hydro Generator (대용량 수차발전기 부분방전 검출용 센서의 신뢰성 평가)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.40-45
    • /
    • 2006
  • In the operation of large capacity hydro generators, it's a very important thing that to minimize several kind of electrical trouble and accident. In order to overcome these problems, the on-line and off-line partial discharge (PD) measuring method has become an important one. Nowadays, epoxy mica coupler(EMC) has been the most widely used sensors for on-line PD detection in rotating machines. This time, we have made a ceramic coupling sensor using $SrTiO_{3}$, because at present, most of sensors has high cost and difficult procedure to making. This paper deals with the electrical characteristics of a ceramic coupling sensor, which has been made to continuously measure PD activity during the operation condition for 13kV class hydro generator. And we have performed the evaluation of sensor life and reliability based on the characteristic testing. The experimental results confirm that the sensor has satisfied at electrical required performance and output characteristic for simulated input signal.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

Detection of Series Arc Signal in Low-voltage Systems (저압계통에서 직렬아크신호의 검출)

  • Ji, Hong-Keun;Park, Chan-Yong;Kil, Gyung-Suk;Kim, Il-Kwon;Cho, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.316-320
    • /
    • 2008
  • This paper described the design and fabrication of a series arc detection module to monitor electrical insulation in low-voltage system. The module consists of a passive high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. For the application experiment, we simulated series arcing phenomena on various loads such as incandescent lamp controlled by dimmer and inverter fed induction motors by an arc generator specified in UL1699. From the experimental results, we could detect series arc signals without an influence of noises.

  • PDF

Propagation Characteristics of Acoustic Signals Produced by Partial Discharge in Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Kim, Sung-Wook;Park, Chan-Yong;Park, Dae-Won;Kil, Gyung-Suk;Rhyu, Keel-Soo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.841-847
    • /
    • 2009
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. To measure small acoustic signals produced by PD, we fabricated an amplifier and simulated PD at a needle-plane electrode system set in insulation oil. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz$\sim$1.6 MHz. These are enough characteristics for the measurement of acoustic signals. After a comparative calibration experiment by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil.

  • PDF

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.

A Development of Hardware-in-the-Loop Simulation System of Automatic Transmission for the Simulation of Shifting Characteristics (자동변속기의 변속특성시뮬레이션을 위한 HILS시스템 개발)

  • 정규홍;이교일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.143-151
    • /
    • 2001
  • During the past several years, the major interests of car manufacturers in development of automatic transmission were in durability and shift quality. However, a large number of researches for improving shift quality that are based on dynamic characteristics of shifting mechanism have been rarely adopted in the developing process because it is quite difficult to predict the shifting performance from the dynamics simulation. One of the important reasons for the difference between simulation results and experiments arises from the automatic transmission hydraulic system that consists of many valves with high order model and shows a lot different dynamics to temperature variation. In this work, hardware-in-the-loop simulation system for automatic transmission was developed f3r improving the accuracy of simulated result by combining the real-time simulation model with the real hydraulic system. The real-time simulation for automatic transmission model excluding hydraulic system is executed with TI's TMS320C31 DSP and the interfacing board which includes 12bit A/D, PWM signal generator and driver, serial driver ,etc is designed for acquiring the simulation data and signal interface with hydraulic system. We verified the proper operation and correctness of shifting result by comparing the off-line simulation result with that of HILS and experimental result which was performed on transmission dynamometer driven by electric motor.

  • PDF