• Title/Summary/Keyword: Simulated Power Line

Search Result 235, Processing Time 0.04 seconds

The Design and Characteristics of the Line Coupler for Power Line Modem (전력선 모델을 위한 Line-Coupler의 설계 및 특성)

  • Park, Chong-Yeun;Cho, Gye-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3132-3134
    • /
    • 1999
  • To realize the power line communication system, the line coupler is one of the most important systems, which must be adjustable to the power line characteristics. In this paper, three kinds of line couplers were designed and simulated with the Pspice, which could be useful to the power line communication systems in C-Band(95kHz-148.5kHz) frequency

  • PDF

Analysis of Performance of Data Communications Using Error Control Codes on Electrical Power Lines (전력선에서의 에러 정정 코드에 의한 데이터 전송 성능 분석)

  • 송왕철;정호영;김신령;강창언
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.5
    • /
    • pp.339-346
    • /
    • 1991
  • In this paper the performance of communication system in the electrical power line using error correcting codes is analysed. The BCH codes and interleaved code are to be used for correcting burst and random errors in the power line channels. The data rate of 2400 bps and the carrier frequency of 12KHz are assumed. Actual power line noise is recorded and simulated in the BPSK PLC system model.

  • PDF

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

Power Line Modelling and Case Study for Indoor Power Line Network Analysis (옥내 전력선망 분석을 위한 전력선 모델링과 사례 연구)

  • Kim, Won-Ho;HwangBo, Hoon;Nah, Wan-Soo;Park, Il-Han;Kim, Byung-Sung;Kim, Chang-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2324-2326
    • /
    • 2005
  • For the analysis of domestic Indoor power line network, we defined parameters of transmission line and simulated it. We conducted the case study which shows the general characteristics of KSC3302 power line. We will develop software for indoor power line network analysis.

  • PDF

Performance of Double Binary Turbo Code for Power Line Communicaion Systems (고속 전력선통신 시스템의 비이진 터보 부호 성능)

  • Lee, Jae-Sun;Yang, Jae-Su;Woo, Sang-Kyu;Yoon, Byung-Wan;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, performance of a turbo-coded PLC system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, Max-Log-MAP algorithms are chosen and performances are compared. The results in this paper can be applied to OFDM-based high-speed power line communication systems

  • PDF

Turbo Coded OFDM Scheme for a High-Speed Power Line Communication (고속 전력선통신 시스템의 터보 부호화)

  • Lee, Jae-Sun;Kim, Yo-Cheol;Kim, Jung-Hui;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.190-196
    • /
    • 2009
  • In this paper, performance of a turbo-coded OFDM system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, MAP (maximum a posteriori), Max-Log-MAP, and SOVA (soft decision Viterbi output) algorithms are chosen and their performances are compared. From simulation results, it is demonstrated that Max-Log-MAP algorithm is promising in terms of performance and complexity. It is shown that performance is substantially improved by increasing the number of iterations and interleaver length of a turbo encoder. The results in this paper can be applied to OFDM-based high-speed power line communication systems.

  • PDF

A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay (송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구)

  • Seo H. C.;Lee H. H.;Kim C. H.;Lee J. W.;Jang B. T.;Gwak N. H.;Kim H. P.;Kim l. D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF

A Study on the TRV(SLF) of Circuit Breakers According to Install Current Limit Reactors (345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(근거리 고장시) 검토)

  • Park, H.S.;Kwak, J.S.;Ju, H.J.;Ryu, H.Y.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.371-373
    • /
    • 2005
  • An enhancement for a transmission and substation equipment in power system make the system impedance to be lower. In principle, if the system impedance become low, system stability will be better, but the fault current become very higher. It is a very big problem for CB operating. As a fact of CB operating performance, high amplitude of the fault current may cause CB operation failure because of exceeding standard value in TRV. So we simulated TRV by using the EMTP. Generally there are two types of TRV in actual power system. One is short line fault, the other is bus terminal fault. In this paper, we simulated the TRv at short line fault as installed current limit reactors to reduce fault current in 345kV ultra-high voltage system. Short line fault is caused from single line fault in transmission line.

  • PDF

Power System Education System using 3-Dimensional Graphic Animation (3차원 그래픽 애니메이션을 이용한 전력계통 교육시스템)

  • Park, In-Kwon;Won, Jong-Ryul;Lee, Jin;Yoon, Yong-Beum
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • This paper presents an efficient system for power system education using 3-D computer graphics animation in the PC environment. Several power system phenomena are simulated using Real-Time Digital Simulator. Results are transmitted through on-line communication line to PC for graphic animation, and simulated in the 3-D graphics animation. It can immediately reflect user control input and re-simulated this result. The proposed method was tested on both the sub-synchronous resonance phenomena and multi-bus system. It is expected that the proposed method would be helpful for the operator training as well as power system education.

  • PDF