• Title/Summary/Keyword: Simulated Distribution System

Search Result 519, Processing Time 0.031 seconds

Application of Simulated Annealing and Tabu Search for Loss Minimization in Distribution Systems (베전 계통의 손실 최소화를 위한 시뮬레이티드 어닐링과 타부 탐색의 적용)

  • Jeon, Young-Jae;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.28-37
    • /
    • 2001
  • This paper presents an efficient algorithm for the loss minimization of distribution system by automatic sectionalizing switch operation in large scale distribution systems. Simulated annealing is particularly well suited for large combinational optimization problem, but the use of this algorithm is also responsible for an excessive computation time requirement. Tabu search attempts to determine a better solution in the manner of a greatest-descent algorithm, but it can not give any guarantee for the convergence property. The hybrid algorithm of two methods with two tabu lists and the proposed perturbation mechanism is applied to improve the computation time and convergence property Numerical examples demonstrate the validity and effectiveness of the proposed methodology using a KEPCO's distribution system.

  • PDF

Implementation of Simulated Annealing for Distribution System Loss Minimum Reconfiguration (배전 계토의 손실 최소 재구성을 위한 시뮬레이티드 어닐링의 구현)

  • Jeon, Young-Jae;Choi, Seung-Kyo;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.371-378
    • /
    • 1999
  • This paper presents an efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in large scale distribution systems of radial type. Simulated Annealing algorithm among optimization techniques can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing algorithm, we may use advanced Simulated Annealing algorithm. All constaints are divided into two constraint group by using perturbation mechanism and penalty factor, so all trail solutions are feasible. The polynomial-time cooling schedule is used which is based on the statistics calculation during the search. This approaches results in saving CPU time. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF

Application of Simulated Annealing for Loss Reduction in Distribution System (배전 계통에서 손실 감소를 위한 시뮬레이티드 어닐링의 적용)

  • Jeon, Young-Jae;Choi, Seung-Kyoo;Kim, Hun;Lee, Seung-Youn;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.335-337
    • /
    • 1998
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. Simulated Annealing can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing Algorithm, we may use advanced Simulated Annealing Algorithm. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF

Corrosion Characteristics by CCPP Control in Simulated Distribution System (CCPP 조절에 따른 모의 상수관로의 부식특성에 관한 연구)

  • Kim, Do-Hwan;Lee, Jae-In;Lee, Ji-Hyung;Han, Dong-Yueb;Kim, Dong-Youn;Hong, Soon-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1249-1256
    • /
    • 2005
  • This study was performed to investigate the efficiency of the corrosion prevention in the simulated distribution system using CCPP(Calcium Carbonate Precipitation Potential) as the anti-corrosive index by adjusting pH, total dissolved solids, alkalinity and calcium hardness in the water treatment pilot process. The materials of the simulated distribution system(SDS) were equiped with same materials of real field water distribution system. CCPP concentrations controlled by $Ca(OH)_2$, $CO_2$ gas and $Na_2CO_3$ in the simulated distribution system and uncontrolled by the chemicals in the general water distribution system were average 0.61 mg/L and -7.77 mg/L. The concentrations of heavy metals like Fe, Zn, Cu ions in effluent water of the simulated distribution system controlled with water quality were decreased rather than the general water distribution system uncontrolled with water quality. In simulated distribution system(SDS), corrosion prevention film formed by CCPP control was observed that scale was come into forming six months later and it was formed into density as time goes on. We were analyzed XRD(X-ray diffraction) for investigating component of crystal compounds and structure for galvanized steel pipe(15 mm). Finding on analysis, scale was compounded to $Zn_4CO_3(OH)_6{\cdot}H_2O$ (Zinc Carbonate Hydroxide Hydrate) after ten months late, and it was compounded on $CaCO_3$(Calcium Carbonate) and $ZnCO_3$(Smithsonite) after nineteen months later.

Study on the aquifer utilization for a ground water heat pump system (지하수 히트펌프 시스템의 대수층 활용 사레 연구)

  • Shim, Byoung-Ohan;Lee, Chul-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Comparative Studies on the Simulation for the Monthly Runoff (월유출량의 모의발생에 관한 비교 연구)

  • 박명근;서승덕;이순혁;맹승진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.4
    • /
    • pp.110-124
    • /
    • 1996
  • This study was conducted to simulate long seres of synthetic monthly flows by multi-season first order Markov model with selection of best fitting frequency distribution, harmonic synthetic and harmonic regression models and to make a comparison of statistical parameters between observes and synthetic flows of five watersheds in Geum river system. The results obtained through this study can be summarized as follow. 1. Both gamma and two parameter lognormal distributions were found to be suitable ones for monthly flows in all watersheds by Kolmogorov-Smirnov test. 2. It was found that arithmetic mean values of synthetic monthly flows simulated by multi-season first order Markov model with gamma distribution are much closer to the results of the observed data in comparison with those of the other models in the applied watersheds. 3. The coefficients of variation, index of fluctuation for monthly flows simulated by multi-season first order Markov model with gamma distribution are appeared closer to those of the observed data in comparison with those of the other models in Geum river system. 4. Synthetic monthly flows were simulated over 100 years by multi-season first order Markov model with gamma distribution which is acknowledged as a suitable simulation modal in this study.

  • PDF

Temperature Control and Wafer Temperature Distribution Simulation in RTA System (RTA 시스템에서의 온도제어와 웨이퍼상의 온도분포 Simulation)

  • 조병진;김경태;김충기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.6
    • /
    • pp.647-653
    • /
    • 1988
  • A rapid thermal annealing system using tungsten halogen lamp has been designed and assembled. A control scheme where the temperature control is executed with calculated wafer temperature by considering the thermocouple delay rather than measured thermocouple temperature,is proposed. This control scheme gives more accurate control of the wafer temperature. In addition, the distribution of transmitted light power to the wafer in the system has been simulated, and lamp interval modification has been able to give more uniform light power distribution. Considering incident light spectrum, absorption, reflection, radiation of silicon, etc., temperature profile has been simulated. When the light power uniformity on the 3" wafer is below 1%, the temperature uniformity is about 2%.

  • PDF

Lightning Surge Analysis on Underground System in DC Combined Distribution System (DC 혼합배전시스템에서 지중계통의 뇌과전압 해석)

  • An, Chun-Yong;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.737-743
    • /
    • 2013
  • This paper describes the overvoltage through lightning surge analysis on underground system in DC combined distribution systems. It is considered that operating micro grid including distributed generation with smart grid can make possibility of composing new distribution system different from existing one. However, there are many papers about low voltage DC distribution in grids or buildings but not many about replacement or distributing 22.9kV AC distribution system to DC system. Among many research need for DC system development, overvoltage is studied in this paper. Overvoltage is simulated on DC cable when lightning strikes to overhead grounding wire which is installed at the nearest location from power cable section. Analysis as well as modeling is performed in EMTP/ATPDraw. It is evaluated that analysis results can be used to design of DC underground distribution power cable system.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility (하나로 유동모의 시험설비의 노심채널 유동분포 해석)

  • Park Y C.;Kim K. R.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF