• Title/Summary/Keyword: Simplified water

Search Result 376, Processing Time 0.029 seconds

On the Estimation of Daily Maximum Precipitation in the Central Part of Korea. (우리나라 중부 지방의 일최대강수량 추정에 관하여)

  • 이래영
    • Water for future
    • /
    • v.11 no.1
    • /
    • pp.59-68
    • /
    • 1978
  • According to the simplified Gringorten's method of extreme values from data samples, daily maximum precipitation and return period at several stations in the central part of Korea were estimated. And also, it was known that the distribution of daily maximum precipitation of Sogcho, Chuncheon, Kangreung, Seoul, Inchon, Suwon, Seosan, Cheongju and Daejeon area belong to an exponential type of distribution.

  • PDF

PARAMETER DEPENDENCE OF STEAM EXPLOSION LOADS AND PROPOSAL OF A SIMPLE EVALUATION METHOD

  • MORIYAMA, KIYOFUMI;PARK, HYUN SUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.907-914
    • /
    • 2015
  • The energetic steam explosion caused by contact between the high temperature molten core and water is one of the phenomena that may threaten the integrity of the containment vessel during severe accidents of light water reactors (LWRs). We examined the dependence of steam explosion loads in a typical reactor cavity geometry on selected model parameters and initial/boundary conditions by using a steam explosion simulation code, JASMINE, developed at Japan Atomic Energy Agency (JAEA). Among the parameters, we put an emphasis on the water pool depth that has significance in terms of accident mitigation strategies including cavity flooding. The results showed a strong correlation between the load and the premixed mass, defined as the mass of the molten material in low void zones (void fraction < 0.75). The jet diameter and velocity that comprise the flow rate were the primary factors to determine the premixed mass and the load. The water pool depth also showed a significant impact. The energy conversion ratio based on the enthalpy in the premixed mass was in a narrow range ~4%. Based on this observation, we proposed a simplified method for evaluation of the steam explosion load. The results showed fair agreement with JASMINE.

Random dynamic analysis for simplified vehicle model based on explicit time-domain method

  • Huan Huang;Yuyu Li;Wenxiong Li;Guihe Tang
    • Coupled systems mechanics
    • /
    • v.12 no.1
    • /
    • pp.1-20
    • /
    • 2023
  • On the basis of the explicit time-domain method, an investigation is performed on the influence of the rotational stiffness and rotational damping of the vehicle body and front-rear bogies on the dynamic responses of the vehicle-bridge coupled systems. The equation of motion for the vehicle subsystem is derived employing rigid dynamical theories without considering the rotational stiffness and rotational damping of the vehicle body, as well as the front-rear bogies. The explicit expressions for the dynamic responses of the vehicle and bridge subsystems to contact forces are generated utilizing the explicit time-domain method. Due to the compact wheel-rail model, which reflects the compatibility requirement of the two subsystems, the explicit expression of the evolutionary statistical moment for the contact forces may be performed with relative ease. Then, the evolutionary statistical moments for the respective responses of the two subsystems can be determined. The numerical results indicate that the simplification of vehicle model has little effect on the responses of the bridge subsystem and the vehicle body, except for the responses of the rotational degrees of freedom for the vehicle subsystem, regardless of whether deterministic or random analyses are performed.

Simplified Ground-type Single-plate Electrowetting Device for Droplet Transport

  • Chang, Jong-Hyeon;Kim, Dong-Sik;Pak, James Jung-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The current paper describes a simpler ground-type, single-plate electrowetting configuration for droplet transport in digital microfluidics without performance degradation. The simplified fabrication process is achieved with two photolithography steps. The first step simultaneously patterns both a control electrode array and a reference electrode on a substrate. The second step patterns a dielectric layer at the top to expose the reference electrode for grounding the liquid droplet. In the experiment, a $5{\mu}m$ thick photo-imageable polyimide, with a 3.3 dielectric constant, is used as the dielectric layer. A 10 nm Teflon-AF is coated to obtain a hydrophobic surface with a high water advancing angle of $116^{\circ}$ and a small contact angle hysteresis of $5^{\circ}$. The droplet movement of 1 mM methylene blue on this simplified device is successfully demonstrated at control voltages above the required 45 V to overcome the contact angle hysteresis.

Design Charts and Simplified Formulae for Anchored Sheet Pile Wall- Using Equivalent Beam Analysis for Fixed End Supported Wall - (앵커식 널말뚝벽의 설계용 도표와 간편식- 고정지지 널말뚝의 등가보 해석을 사용하여 -)

  • 김기웅;원진오;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.19-30
    • /
    • 2000
  • The major design parameters of the anchored sheet-pile wall include the determination of required penetration depth, the force acting on the anchor, and the maximum bending moment in the piling. Blum solved the fixed earth supported wall using the equivalent beam method, assuming that the wall can be separated into upper and lower parts of the point of contraflexure. Design charts help designer by simplifying the design procedure. But they have some difficulties under some Geotechnical and geometrical conditions. For example, the conventional design charts can compute design parameters only when the ground water table exists above the dredge line. In this paper, the design charts which can be used for the ground water table existing under the dredge line are presented. And simplified formulae are developed by regression analysis. It is found that simplified formulae are not only very useful for the practice of design but also they can evaluate the result of numerical methods or design charts.

  • PDF

A Simplified Reynolds Stress Model with Turbulent Kinetic Energy-Length Scale (난류운동에너지-길이 Scale을 사용하는 단순화된 Reynolds 응력모형)

  • Huh Jae-Yeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.404-408
    • /
    • 2005
  • The Reynolds strss equation with turbulent energy-length scales was simplified in the nearly homogeneous turbulent equilibrium flow and a modified Reynolds stress model was proposed. Tn the model proposed in the present study, Reynolds stresses can be expressed in the form of algebraic equation, so that the turbulent stresses and related quantities are calculated through relatively simple procedures. The model predicted well the turbulent shear stresses of homogeneous flow in local equilibrium state obtained from experimental results published earlier Constants used In the model was determined universally and its validity was discussed briefly.

  • PDF

Energy Regression Analysis for Economic Evaluation of Cooling Plants (냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출)

  • 김영섭;김강수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

Hydrologic Safety Evaluation of Small Scale Reservoir by Simplified Assesment Method (간편법에 의한 소규모저수지의 수문학적 안전성 평가)

  • Lee, Joo-Heon;Yang, Seung-Man;Kim, Seong-Joon;Kang, Boo-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.2
    • /
    • pp.9-17
    • /
    • 2011
  • Based on the statistical annual report, there are 17,649 reservoirs are operating for the purpose of agricultural water supply in Korea. 58 % of entire agricultural reservoirs had been constructed before 1948 which indicate the termination of required service life and rest of those reservoirs have also exposed to the dam break risk by extreme flood event caused by current ongoing climate change. To prevent damages from dam failure accident of these risky small size dams, it is necessary to evaluate and manage the structural and hydrological safety of the reservoirs. In this study, a simplified evaluation method for hydrologic safety of dam is suggested by using Rational and Creager formula. Hydrologic safety of small scale dams has evaluated by calculating flood discharge capacity of the spillway and compares the results with design frequency of each reservoir. Applicability and stability of suggested simplified method have examined and reviewd by comparing the results from rainfall-runoff modeling with dam break simulation using HEC-HMS. Application results of developed methodology for three sample reservoirs show that simplified assessment method tends to calculate greater inflow to the reservoirs then HEC-HMS model which lead lowered hydrologic safety of reservoirs. Based on the results of application, it is expected that the developed methodology can be adapted as useful tool for small scale reservoir's hydrologic safety evaluation.

Evaluation of Efficiency of Livestock Vehicle Disinfection Systems Using Water-Sensitive Paper (감수 시험지를 활용한 축산시설 차량소독시스템의 소독액 분사 효율성 평가)

  • Park, Jinseon;Hong, Se-Woon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.87-97
    • /
    • 2020
  • The livestock infections had been happened seasonally, but they have gradually changed to be irrelevant to seasons and have an aspect to rapidly spread after outbreak. Especially in Korea, proactive disinfection measures are very important because the livestock farms are located densely so high as to accelerate the spread of disease between farms. livestock disease outbreaks like HPAI and FMD occurred with high probability due to vehicles visiting the farms, this study is to evaluate the efficiency of livestock vehicle disinfection systems by investigating the disinfectant coverage according to the type of vehicle disinfection system and the type of vehicle quantitatively. In field experiments, water-sensitive papers (WSPs) were attached to 21 locations on the surface of four vehicles (sedan, SUV, truck, and feed transport), respectively, and exposed to disinfectants while the vehicle was sprayed in two vehicle disinfection systems (tunnel type and simplified type). The WSPs were scanned and image-processed to calculate the disinfectant coverage. The results showed that the tunnel-type vehicle disinfection system had a better disinfection performance with an average coverage of 90.27% for all vehicles compared to 32.62% of the simplified type system. The problem of the simplified system was a wide coefficient of variation (1.05-1.31) of the disinfectant coverage between 21 locations indicating a need for further improvement of nozzle location and arrangement.